This study is aimed at characterizing three signal entropy measures, Approximate Entropy (ApEn), Sample Entropy (SampEn) and Multiscale Entropy (MSE) over real EEG signals when a number of samples are randomly lost due to, for example, wireless data transmission. The experimental EEG database comprises two main signal groups: control EEGs and epileptic EEGs. Results show that both SampEn and ApEn enable a clear distinction between control and epileptic signals, but SampEn shows a more robust performance over a wide range of sample loss ratios. MSE exhibits a poor behavior for ratios over a 40% of sample loss. The EEG non-stationary and random trends are kept even when a great number of samples are discarded. This behavior is similar for all the records within the same group.