Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Catheter Cardiovasc Interv ; 81(6): 970-7, 2013 May.
Article in English | MEDLINE | ID: mdl-22581763

ABSTRACT

OBJECTIVES: Assess accuracy of Helix injections via fluoroscopic-mapping and evaluate delivery safety. BACKGROUND: Percutaneous intramyocardial-delivery of agents must be safe and accurate; retention is also important. A delivery system (Helical Infusion/Morph Guide-Catheter, Biocardia Inc) has been developed to improve maneuverability and stability of catheter-needle-myocardium intersection. METHODS: Accuracy and safety: 12 swine underwent LV and coronary angiography via 8F sheath. Targeted delivery was assigned into LAD, LCX, or RCA. System was advanced into LV and 6 targeted intramyocardial dye injections (5 mm apart) delivered using fluoroscopy. After euthanization, hearts underwent gross and histologic evaluation. Retention was assessed by iron-oxide and fluorochrome labeled CD34+ cells. Cells were injected into 6 swine using same techniques. Delivery system was advanced into LV, and injections delivered using fluoroscopy. Euthanization was performed at 2 hr and hearts formalin fixed. MRI was performed on 6 treated hearts and 4 untreated controls. Blinded analysis performed by 2 radiologists. Two treated hearts underwent immunohistological analysis. RESULTS: Accuracy and safety evaluation: 71/72 injections (98.6%) were within prespecified zone; 7/72 (9.7%) less than 5 mm apart. No adverse events occurred. MRI-presence of iron-oxide labeled CD34+ cells were correctly identified in 95% (19/20) of imaged injections. Anti-CD34+ antibody staining and fluorescence microscopy confirmed CD34+ cells in myocardium. Histology confirmed cell viability at fixation. CONCLUSIONS: Helix system was accurate and safe. Retention of CD34+ cells was confirmed by MRI and immunohistology. Further preclinical studies are needed to characterize retention over time and quantify efficiency. Studies are needed to confirm accuracy, safety, and retention in humans.


Subject(s)
Antigens, CD34/metabolism , Catheters , Hematopoietic Stem Cell Transplantation/instrumentation , Hematopoietic Stem Cells/metabolism , Myocardium/metabolism , Needles , Animals , Biomarkers/metabolism , Cell Survival , Coronary Angiography , Equipment Design , Fluoroscopy , Hematopoietic Stem Cell Transplantation/adverse effects , Hematopoietic Stem Cell Transplantation/methods , Humans , Immunohistochemistry , Injections, Intramuscular , Magnetic Resonance Imaging , Microscopy, Fluorescence , Models, Animal , Radiography, Interventional/methods , Swine , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...