Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 20(2): 1253-60, 2012 Jan 16.
Article in English | MEDLINE | ID: mdl-22274470

ABSTRACT

A Continuous Wave (CW) sub-THz photonic synthesis setup based on a single Passively Mode-Locked Laser Diode (PMLLD) acting as a monolithic Optical Frequency Comb Generator (OFCG) and highly selective optical filtering has been implemented to evaluate the phase noise performance of the generated sub-THz signals. The analysis of the synthesized sub-THz signals up to 120 GHz gives as a result an effective reduction of the electrical linewidth when compared to direct harmonic generation that begins at 50 GHz and becomes greater as the frequency increases. The phase noise reduction offered by the setup, along with its integration potential, cost and bandwidth, make it a promising candidate to the development of an integrated and high performance low phase noise local oscillator in the sub-THz range.


Subject(s)
Lasers, Semiconductor , Optics and Photonics/instrumentation , Optics and Photonics/methods , Signal Processing, Computer-Assisted/instrumentation , Artifacts , Equipment Design
2.
Rev Sci Instrum ; 81(10): 10D517, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21033872

ABSTRACT

A high spatial resolution two color [CO(2), λ=10.6 µm/Nd:YAG (Nd:YAG denotes neodymium-doped yttrium aluminum garnet), and λ=1.064 µm] expanded-beam multichannel heterodyne interferometer has been installed on the TJ-II stellarator. Careful design of the optical system has allowed complete control on the evolution of both Gaussian beams along the interferometer, as well as the evaluation and optimization of the spatial resolution to be expected in the measurements. Five CO(2) (measurement) channels and three Nd:YAG (vibration compensation) channels have been used to illuminate the plasma with a probe beam of 100 mm size. An optimum interpolation method has been applied to recover both interferometric phasefronts prior to mechanical vibration subtraction. The first results of the installed diagnostic are presented in this paper.

3.
Rev Sci Instrum ; 79(10): 10E713, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19044531

ABSTRACT

A high spatial resolution two-color (CO(2), lambda=10.6 microm, He-Ne, lambda=633 nm) interferometer for density profile measurements in the TJ-II stellarator is under development and installation, based in the currently operational single channel two-color heterodyne interferometer. To achieve the objectives of 32 channels, with 4-5 mm lateral separation between plasma chords, careful design and calibration of the interferometric waveforms for both the measurement and vibration compensation wavelengths are undertaken. The first step has been to set up in our laboratories an expanded-beam heterodyne/homodyne interferometer to evaluate the quality of both interferometric wavefronts, a reported source of poor vibration compensation and thus low resolution in the density profile measurements. This novel interferometric setup has allowed us to calibrate the spatial resolution in the profile measurements resulting in approximately 2 mm lateral resolution in the reconstruction of the interferometric wavefront.

SELECTION OF CITATIONS
SEARCH DETAIL
...