Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Curr Res Physiol ; 6: 100103, 2023.
Article in English | MEDLINE | ID: mdl-37554388

ABSTRACT

Objective: The purpose of this study was to determine if uterine electrophysiological signals gathered from 151 non-invasive biomagnetic sensors spread over the abdomen were associated with successful induction of labor (IOL). Study design: Uterine magnetomyogram (MMG) signals were collected using the SARA (SQUID Array for Reproductive Assessment) device from 33 subjects between 37 and 42 weeks gestational age. The signals were post-processed, uterine contractile related MMG bursts were detected, and parameters in the time and frequency domain were extracted. The modified Bishop score calculated at admission was used to determine the method of IOL. Wilcoxon's rank-sum test was used to compare IOL successes and failures for differences in gestational age (GA), parity, modified Bishop's score, maximum oxytocin, and electrophysiological parameters extracted from MMG. Results: The average parity was three times (3x) higher (1.53 versus 0.50; p = 0.039), and the average modified Bishop score was 2x higher (3.32 versus 1.63; p = 0.032) amongst IOL successes than failures, while the average GA and maximum oxytocin showed a small difference. For the MMG parameters, successful IOLs had, on average, 3.5x greater mean power during bursts (0.246 versus 0.070; p = 0.034) and approximately 1.2x greater mean number of bursts (2.05 versus 1.68; p = 0.036) compared to the failed IOLs, but non-significant differences were observed in mean peak frequency, mean burst duration, and mean duration between bursts. Conclusion: The study showed that inductions of labor that took less than 24 h to deliver have a higher mean power in the baseline electrophysiological activity of the uterus when recorded prior to planned induction. The results are indicative that baseline electrophysiological activity measured prior to induction is associated with successful induction.

2.
Cardiovasc Eng Technol ; 13(6): 886-898, 2022 12.
Article in English | MEDLINE | ID: mdl-35545752

ABSTRACT

PURPOSE: Peripheral venous pressure (PVP) waveform analysis is a novel, minimally invasive, and inexpensive method of measuring intravascular volume changes. A porcine cohort was studied to determine how venous and arterial pressure waveforms change due to inhaled and infused anesthetics and acute hemorrhage. METHODS: Venous and arterial pressure waveforms were continuously collected, while each pig was under general anesthesia, by inserting Millar catheters into a neighboring peripheral artery and vein. The anesthetic was varied from inhaled to infused, then the pig underwent a controlled hemorrhage. Pearson correlation coefficients between the power of the venous and arterial pressure waveforms at each pig's heart rate frequency were calculated for each variation in the anesthetic, as well as before and after hemorrhage. An analysis of variance (ANOVA) test was computed to determine the significance in changes of the venous pressure waveform means caused by each variation. RESULTS: The Pearson correlation coefficients between venous and arterial waveforms decreased as anesthetic dosage increased. In an opposing fashion, the correlation coefficients increased as hemorrhage occurred. CONCLUSION: Anesthetics and hemorrhage alter venous pressure waveforms in distinctly different ways, making it critical for researchers and clinicians to consider these confounding variables when utilizing pressure waveforms. Further work needs to be done to determine how best to integrate PVP waveforms into clinical decision-making.


Subject(s)
Anesthesia , Arterial Pressure , Swine , Animals , Venous Pressure , Arteries , Hemorrhage/chemically induced , Blood Pressure
SELECTION OF CITATIONS
SEARCH DETAIL
...