Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Am Surg ; 81(3): 282-8, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25760205

ABSTRACT

The position of the base of the appendix during advancing gestational age is based on inadequate data. Therefore, the proper location for an appendectomy incision during pregnancy is highly unclear. This study investigated the location of the appendix during pregnancy to determine the optimal location for an incision in pregnant patients with appendicitis relative to McBurney's point. Magnetic resonance images (MRIs) were reviewed independently by two fellowship-trained abdominal MRI radiologists blinded to the imaging report. The distance of the appendix from anatomic landmarks was measured in a total of 114 pregnant women with an abdominal or pelvic MRI who were admitted between 2001 and 2011 at a Level I trauma center. Patients with a history of appendectomy were excluded. The distance from the base of the appendix to McBurney's point changed over the course of the gestation by only 1.2 cm and which did not amount to a clinically or statistically significant change in position. Our data provide evidence that there is minimal upward or lateral displacement of the appendix during pregnancy, and therefore its distance from the McBurney's point remains essentially unchanged. These findings justify the use of the McBurney's incision for appendectomy during pregnancy regardless of the trimester.


Subject(s)
Appendectomy/methods , Appendix/pathology , Appendix/surgery , Pregnancy Complications/pathology , Pregnancy Complications/surgery , Adolescent , Adult , Body Weights and Measures , Female , Humans , Magnetic Resonance Imaging , Pregnancy , Pregnancy Trimesters , Retrospective Studies , Young Adult
2.
J Trauma Acute Care Surg ; 75(3): 398-403, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23928742

ABSTRACT

BACKGROUND: Therapeutic angioembolization is a relatively new "rescue treatment" modality for gastrointestinal hemorrhage (GIH) for unstable patients who fail primary treatment approaches; however, the effectiveness of this treatment and the incidence of ischemic necrosis following embolization for acute GIH are poorly described. The purpose of this study was to evaluate the effectiveness and safety of "rescue" transcatheter superselective angioembolization (SSAE) for the treatment of hemodynamically unstable patients with GIH. METHODS: A 10-year retrospective review of all hemodynamically unstable patients (systolic blood pressure < 90 mm Hg and ongoing transfusion requirement) who underwent "rescue" SSAE for GIH after failed endoscopic management was performed. All patients with evidence of active contrast extravasation were included. Data were collected on demographics, comorbidities, clinical presentation, and type of intravascular angioembolic agent used. Outcomes included technical success (cessation of extravasation), clinical success (no rebleeding requiring intervention within 30 days), and incidence of ischemic complications. RESULTS: Ninety-eight patients underwent SSAE for GIH during the study period; 47 were excluded owing to lack of active contrast extravasation. Of the remaining 51 patients, 22 (43%) presented with a lower GIH and 29 (57%) with upper GIH. The majority underwent embolization with a permanent agent (71%), while the remaining patients received either a temporary agent (16%) or a combination (14%). The overall technical and clinical success rates were 98% and 71%, respectively. Of the 14 patients with technical success but clinical failure (rebleeding within 30 days) and the 1 patient with technical failure, 4 were managed successfully with reembolization, while 2 underwent successful endoscopic therapy, and 9 had surgical resections. Only one patient had an ischemic complication (small bowel necrosis) requiring resection. CONCLUSION: SSAE, with reembolization if necessary, is an effective rescue treatment modality for hemodynamically unstable patients with active GIH. Of the patients, 20% will fail SSAE and require additional intervention. Ischemic complications are extremely rare. LEVEL OF EVIDENCE: Therapeutic study, level IV.


Subject(s)
Embolization, Therapeutic , Gastrointestinal Hemorrhage/therapy , Embolization, Therapeutic/adverse effects , Female , Gastrointestinal Hemorrhage/mortality , Gastrointestinal Hemorrhage/physiopathology , Gastrointestinal Tract/blood supply , Hemodynamics/physiology , Humans , Ischemia/etiology , Male , Middle Aged , Patient Outcome Assessment , Retrospective Studies
3.
J Spec Oper Med ; 13(1): 29-33, 2013.
Article in English | MEDLINE | ID: mdl-23526319

ABSTRACT

INTRODUCTION: The usefulness of heart rate variability (HRV) and heart rate complexity (HRC) analysis as a potential triage tool has been limited by the inability to perform real-time analysis on a portable, handheld monitoring platform. Through a multidisciplinary effort of academia and industry, we report on the development of a rugged, handheld and noninvasive device that provides HRV and HRC analysis in real-time in critically ill patients. METHODS: After extensive re-engineering, real-time HRV and HRC analyses were incorporated into an existing, rugged, handheld monitoring platform. Following IRB approval, the prototype device was used to monitor 20 critically ill patients and 20 healthy controls to demonstrate real-world discriminatory potential. Patients were compared to healthy controls using a Student?s t test as well as repeated measures analysis. Receiver operator characteristic (ROC) curves were generated for HRV and HRC. RESULTS: Critically ill patients had a mean APACHE-2 score of 15, and over 50% were mechanically ventilated and requiring vasopressor support. HRV and HRC were both lower in the critically ill patients compared to healthy controls (p < 0.0001) and remained so after repeated measures analysis. The area under the ROC for HRV and HRC was 0.95 and 0.93, respectively. CONCLUSIONS: This is the first demonstration of real-time, handheld HRV and HRC analysis. This prototype device successfully discriminates critically ill patients from healthy controls. This may open up possibilities for real-world use as a trauma triage tool, particularly on the battlefield.


Subject(s)
Critical Illness , Heart Rate , Entropy , Humans , Monitoring, Physiologic , Triage
SELECTION OF CITATIONS
SEARCH DETAIL
...