Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Clin Chem Lab Med ; 61(8): 1511-1517, 2023 07 26.
Article in English | MEDLINE | ID: mdl-36799248

ABSTRACT

OBJECTIVES: To evaluate pre-analytical challenges related to high-volume central laboratory SARS-CoV-2 antigen testing with a prototype qualitative SARS-CoV-2 antigen immunoassay run on the automated Abbott ARCHITECT instrument. METHODS: Contrived positive and negative specimens and de-identified nasal and nasopharyngeal specimens in transport media were used to evaluate specimen and reagent on-board stability, assay analytical performance and interference, and clinical performance. RESULTS: TCID50/mL values were similar for specimens in various transport media. Inactivated positive clinical specimens and viral lysate (USA-WA1/2020) were positive on the prototype immunoassay. Within-laboratory imprecision was ≤0.10 SD (<1.00 S/C) with a ≤10% CV (≥1.00 S/C). Assay reagents were stable on board the instrument for 14 days. No high-dose hook effect was observed with a SARS-CoV-2 stock of Ct 13.0 (RLU>1.0 × 106). No interference was observed from mucin, whole blood, 12 drugs, and more than 20 cross-reactants. While specimen stability was limited at room temperature for specimens with or without viral inactivation, a single freeze/thaw cycle or long-term storage (>30 days) at -20 °C did not adversely impact specimen stability or assay performance. Specificity of the prototype SARS-CoV-2 antigen immunoassay was ≥98.5% and sensitivity was ≥89.5% across two ARCHITECT instruments. Assay sensitivity was inversely correlated with Ct and was similar to that reported for the Roche Elecsys® SARS-CoV-2 Ag immunoassay. CONCLUSIONS: The prototype SARS-CoV-2 antigen ARCHITECT immunoassay is sensitive and specific for detection of SARS-CoV-2 in nasal and nasopharyngeal specimens. Endogenous proteases in mucus may degrade the target antigen, which limits specimen storage and transport times and complicates assay workflow.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Sensitivity and Specificity , COVID-19 Testing , Immunoassay
2.
J Clin Microbiol ; 60(12): e0135622, 2022 12 21.
Article in English | MEDLINE | ID: mdl-36472424

ABSTRACT

Early-onset neonatal sepsis due to Streptococcus agalactiae (group B Streptococcus [GBS]) infection is one of the leading causes of newborn mortality and morbidity. The latest guidelines published in 2019 recommended universal screening of GBS colonization among all pregnant women and intrapartum antibiotic prophylaxis for positive GBS. The updated procedures allow rapid molecular-based GBS screening using nutrient broth-enriched rectovaginal samples. Commercially available molecular assays for GBS diagnosis target mainly the cfb gene, which encodes a hemolysin protein responsible for producing the Christie-Atkins-Munch-Petersen (CAMP) factor. cfb is considered a conserved gene in essentially all GBS isolates. However, false-negative GBS results on Cepheid Xpert GBS and GBS LB tests due to deletions in or near the region that encodes cfb were reported recently. Therefore, the new Xpert GBS LB XC test was developed. This study is a multicenter evaluation of the new test for GBS identification from nutrient broth-enriched rectal/vaginal samples from antepartum women. A total of 621 samples were prospectively enrolled. The samples were tested with the Xpert GBS LB XC test, the composite comparator method, which included the Hologic Panther Fusion GBS test combined with bacterial culture, followed by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identification, and bacterial culture alone, followed by MALDI-TOF MS identification. The respective sensitivity and specificity of the Xpert GBS LB XC test were 99.3% and 98.7% compared to the composite comparator method and 99.1% and 91.8% compared to bacterial culture alone with MALDI-TOF MS identification. Overall, the Xpert GBS LB XC test performed comparatively to the composite comparator method and is equivalent to traditional bacterial culture followed by MALDI-TOF MS.


Subject(s)
Pregnancy Complications, Infectious , Streptococcal Infections , Infant, Newborn , Pregnancy , Female , Humans , Pregnancy Complications, Infectious/diagnosis , Pregnancy Complications, Infectious/microbiology , Vagina/microbiology , Streptococcus agalactiae/genetics , Streptococcal Infections/diagnosis , Streptococcal Infections/microbiology , Sensitivity and Specificity
3.
Sci Rep ; 12(1): 18525, 2022 11 02.
Article in English | MEDLINE | ID: mdl-36323751

ABSTRACT

Within healthcare settings, physicians use antibiograms, which offer information on local susceptibility rates, as an aid in selecting empirical antibiotic therapy and avoiding the prescription of potentially ineffective drugs. While antibiograms display susceptibility and resistance data at hospital, city, or region-specific levels and ultimately enable the initiation of antibiogram-based empirical antibiotic treatment, AST reports at the individual patient level and guides treatments away from broad-spectrum antibiotics towards narrower-spectrum antibiotics or the removal of antibiotics entirely. Despite these advantages, AST traditionally requires a 48- to 72-h turn-around; this window of time can be critical for some antimicrobial therapeutic interventions. Herein, we present a direct-from-specimen AST to reduce the time between patient sampling and receipt of lab AST results. The biggest challenge of performing AST directly from unprocessed clinical specimens with an unknown microbial load is aligning the categorical susceptibility report with CLSI reference methods, which start from a fixed inoculum of 0.5 McFarland units prepared using colonies from a sub-culture. In this pilot clinical feasibility study using de-identified remnant specimens collected from MCW, we observed the high and low ends of microbial loads, demonstrating a final categorical agreement of 87.5% for ampicillin, 100% for ciprofloxacin, and 100% for sulfamethoxazole-trimethoprim.


Subject(s)
Anti-Bacterial Agents , Ciprofloxacin , Humans , Feasibility Studies , Microbial Sensitivity Tests , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Ciprofloxacin/pharmacology , Ciprofloxacin/therapeutic use , Ampicillin
4.
Am J Clin Pathol ; 156(1): 24-33, 2021 06 17.
Article in English | MEDLINE | ID: mdl-33940605

ABSTRACT

OBJECTIVES: We conducted an analytic and clinical comparison of a novel high-definition polymerase chain reaction PCR (HDPCR) assay to traditional real-time PCR (RT-PCR) for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in upper respiratory specimens. METHODS: Analytic performance of RT-PCR, HDPCR, and extraction-free HDPCR was established through replicate testing of a serially diluted clinical specimen containing SARS-CoV-2. A clinical comparison of all 3 assays was conducted using 351 prospectively collected upper respiratory swab specimens obtained from symptomatic and asymptomatic individuals collected in various transport media. RESULTS: RT-PCR and HDPCR assays using extracted nucleic acid demonstrated similar analytic limits of detection (LoD) and clinical performance, with 100% positive and negative agreement. Extraction-free HDPCR demonstrated a 1.5 to 2.0 log10 increase in LoD based on cycle threshold values. However, clinical performance of extraction-free HDPCR remained high, demonstrating 97.8% positive and 99.6% negative agreement with RT-PCR. An overall increase in "invalid" and "presumptive" results was observed when using the extraction-free method, but this was highly variable based on transport medium used. CONCLUSIONS: HDPCR performs similar to RT-PCR for the detection of SARS-CoV-2. The use of an extraction-free HDPCR protocol maintained high clinical performance despite reduced analytic LoD, with the benefit of reduced hands-on time and cost of reagents associated with nucleic acid extraction.


Subject(s)
COVID-19/genetics , RNA, Viral/analysis , Real-Time Polymerase Chain Reaction , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19 Testing/methods , Humans , Limit of Detection , Real-Time Polymerase Chain Reaction/methods , SARS-CoV-2/pathogenicity , Sensitivity and Specificity , Specimen Handling/methods
5.
PLoS One ; 16(3): e0249203, 2021.
Article in English | MEDLINE | ID: mdl-33770124

ABSTRACT

The emergence and evolution of antibiotic resistance has been accelerated due to the widespread use of antibiotics and a lack of timely diagnostic tests that guide therapeutic treatment with adequate sensitivity, specificity, and antimicrobial susceptibility testing (AST) accuracy. Automated AST instruments are extensively used in clinical microbiology labs and provide a streamlined workflow, simplifying susceptibility testing for pathogenic bacteria isolated from clinical samples. Although currently used commercial systems such as the Vitek2 and BD Phoenix can deliver results in substantially less time than conventional methods, their dependence on traditional AST inoculum concentrations and optical detection limit their speed somewhat. Herein, we describe the GeneFluidics ProMax lab automation system intended for a rapid 3.5-hour molecular AST from clinical isolates. The detection method described utilizes a higher starting inoculum concentration and automated molecular quantification of species-specific 16S rRNA through the use of an electrochemical sensor to assess microbiological responses to antibiotic exposure. A panel of clinical isolates consisting of species of gram-negative rods from the CDC AR bank and two hospitals, New York-Presbyterian Queens and Medical College of Wisconsin, were evaluated against ciprofloxacin, gentamicin, and meropenem in a series of reproducibility and clinical studies. The categorical agreement and reproducibility for Citrobacter freundii, Enterobacter cloacae, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae, and Pseudomonas aeruginosa were 100% and 100% for ciprofloxacin, 98.7% and 100% for gentamicin and 98.5% and 98.5% for meropenem, respectively.


Subject(s)
Anti-Bacterial Agents/pharmacology , Gram-Negative Bacteria/drug effects , Microbial Sensitivity Tests , Phenotype , Feasibility Studies , Species Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...