Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-25571091

ABSTRACT

We study the influence of different conductivity models within the framework of electroencephalogram (EEG) source localization on the white matter and skull areas. Particularly, we investigate five different spherical models having either isotropic or anisotropic conductivity for both considered areas. To this end, the anisotropic finite difference reciprocity method is used for solving the EEG forward problem. We evaluate a model of a numeric skull conductivity in terms of the minimum dipole localization/orientation error. As a result, both considered models of the skull reach the lowest dipole localization error (less than 6 mm), namely: i) single anisotropic layer and ii) three isotropic layers (hard bone/spongy bone/hard bone). Additionally, two different electrode configurations (10-20 and 10-10 systems) are tested showing that the error decreases almost as much as twice for the latter one though the computational burden significantly increases.


Subject(s)
Electroencephalography , Magnetic Resonance Imaging , Skull/physiology , Algorithms , Anisotropy , Brain/physiology , Brain Mapping/methods , Computer Simulation , Electrodes , Head , Humans , Models, Anatomic , Models, Neurological , Signal Processing, Computer-Assisted
2.
Article in English | MEDLINE | ID: mdl-25571095

ABSTRACT

We study the influence of the anisotropic white matter within the ElectroEncephaloGraphy source localization problem. To this end, we consider three cases of the anisotropic white matter modeled in two concrete cases: by fixed or variable ratio. We extract information about highly anisotropic areas of the white matter from real Diffusion Weighted Imaging data. To validate the compared anisotropic models, we introduce the localization dipole and orientation errors. Obtained results show that the white matter model with a fixed anisotropic ratio leads to values of dipole localization error close to 1cm and may be enough in those cases avoiding localized analysis of neural brain activity. In contrast, modeling based on the anisotropic variable rate assumption becomes important in tasks regarding analysis and localization of deep sources neighboring the white matter tissue.


Subject(s)
Electroencephalography/methods , White Matter/anatomy & histology , Anisotropy , Computer Simulation , Diffusion Magnetic Resonance Imaging , Electric Conductivity , Humans , Male , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...