Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Phys Condens Matter ; 30(46): 465002, 2018 Nov 21.
Article in English | MEDLINE | ID: mdl-30259877

ABSTRACT

Quantitative understanding and control of water and impurity desorption from steel surfaces are crucial for high-voltage, pulsed power, vacuum technology, catalysis, and environmental applications. We apply a suite of modeling techniques, ranging from electronic density functional theory, to classical molecular dynamics (MD) and grand canonical Monte Carlo (GCMC) methods to study the thermodynamics and kinetics of fast water desorption from different surfaces of hematite Fe2O3 and Cr2O3. Water binding energies on chromium oxide are found to be higher than iron oxide at zero temperature. MD simulations are conducted on Fe2O3 surfaces using thermodynamically consistent initial water inventory deduced with GCMC. The resulting time- and temperature-dependent desorption profiles on the Fe2O3 [Formula: see text] surfaces show multi-water cooperative behavior which cannot be deduced from zero temperature predictions, but which are in reasonable agreement with simple Temkin isotherm model estimates if finite temperature effects are incorporated into the Temkin binding energy parameter. Qualitatively different desorption behaviors associated with the [Formula: see text] and [Formula: see text] facets are discussed.

2.
Phys Rev Lett ; 112(13): 135002, 2014 Apr 04.
Article in English | MEDLINE | ID: mdl-24745432

ABSTRACT

Recent experiments on Sandia's Z facility have confirmed simulation predictions of dramatically reduced instability growth in solid metallic rods when thick dielectric coatings are used to mitigate density perturbations arising from an electrothermal instability. These results provide further evidence that the inherent surface roughness as a result of target fabrication is not the dominant seed for the growth of magneto-Rayleigh-Taylor instabilities in liners with carefully machined smooth surfaces, but rather electrothermal instabilities that form early in the electrical current pulse as Joule heating melts and vaporizes the liner surface. These results suggest a new technique for substantially reducing the integral magneto-Rayleigh-Taylor instability growth in magnetically driven implosions, such as cylindrical dynamic material experiments and inertial confinement fusion concepts.

3.
Phys Rev E Stat Nonlin Soft Matter Phys ; 79(1 Pt 2): 016412, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19257153

ABSTRACT

We report the results of a series of current scaling experiments with the Z accelerator for the compact, single, 20-mm diameter, 10-mm long, tungsten-wire arrays employed for the double-ended hohlraum ICF concept [M. E. Cuneo, Plasma Phys. Controlled Fusion 48, R1 (2006)]. We measured the z -pinch peak radiated x-ray power and total radiated x-ray energy as a function of the peak current, at a constant implosion time tau_{imp}=80ns . Previous x-ray emission current scaling for these compact arrays was obtained at tau_{imp}=95ns in the work of Stygar [Phys. Rev. E 69, 046403 (2004)]. In the present study we utilized lighter single-tungsten-wire arrays. For all the measurements, the load hardware dimensions, materials, and array wire number (N=300) were kept constant and were the same as the previous study. We also kept the normalized load current spatial and temporal profiles the same for all experiments reported in this work. Two different currents, 11.2+/-0.2MA and 17.0+/-0.3MA , were driven through the wire arrays. The average peak x-ray power for these compact wire arrays increased by 26%+/-7%to158+/-26TW at 17+/-0.3MA from the 125+/-24TW obtained at a peak current of 18.8+/-0.5MA with tau_{imp}=95ns . The higher peak power of the faster implosions may possibly be attributed to a higher implosion velocity, which in turn improves the implosion stability, and/or to shorter wire ablation times, which may lead to a decrease in trailing mass and trailing current. Our results show that the scaling of the radiated x-ray peak power and total radiated x-ray energy scaling with peak drive current to be closer to quadratic than the results of Stygar We find that the x-ray peak radiated power is P_{r} proportional, variantI;{1.57+/-0.20} and the total x-ray radiated energy E_{r} proportional, variantI;{1.9+/-0.24} . We also find that the current scaling exponent of the power is sensitive to the inclusion of a single data point with a peak power at least 1.9sigma below the average. If we eliminate this particular shot from our analysis (shot 1608), the power and energy scaling becomes closer to quadratic. Namely, we find that the dependence on the peak load current of the peak x-ray radiated power and the total x-ray radiated energy become P_{r} proportional, variantI;{1.71+/-0.10} and E_{r} proportional, variantI;{2.01+/-0.21} , respectively. In this case, the power scaling exponent is different by more than 2sigma from the previously published results of Stygar Larger data sets are likely required to resolve this uncertainty and eliminate the sensitivity to statistical fluctuations in any future studies of this type. Nevertheless, with or without the inclusion of shot 1608, our results with tau_{imp}=80ns fall short of an I2 scaling of the peak x-ray radiated power by at least 2sigma . In either case, the results of our study are consistent with the heuristic wire ablation model proposed by Stygar (P_{r} proportional, variantI;{1.5}) . We also derive an empirical predictive relation that connects the power scaling exponent with certain array parameters.

4.
Appl Opt ; 43(19): 3772-96, 2004 Jul 01.
Article in English | MEDLINE | ID: mdl-15250544

ABSTRACT

A new analytical model, derived rigorously from scalar diffraction theory, accurately fits soft-x-ray measurements of symmetrical profile gold transmission gratings in all diffracted orders. The calibration system selects numerous photon energies by use of a high-resolution grazing-incidence monochromator and a dc e-beam source. Fine-period free-standing gratings exhibit limited performance and require such testing to determine parameters of and select acceptable gratings for use in time-resolved (0.25 ns) spectrographs of known radiometric response. Unfolded spectra yield a Z-pinch plasma peak kT approximately 250 eV, total radiated energy approximately 900 kJ, and a pinch-driven gold-wall hohlraum Planckian kT approximately 86 eV.

5.
Appl Opt ; 42(19): 4059-71, 2003 Jul 01.
Article in English | MEDLINE | ID: mdl-12868848

ABSTRACT

X-ray backlighting and microscopy systems for the 1-10-keV range based on spherically or toroidally bent crystals are discussed. These systems are ideal for use on the Sandia Z machine, a megajoule-class x-ray facility. Near-normal-incidence crystal microscopy systems have been shown to be more efficient than pinhole cameras with the same spatial resolution and magnification [Appl. Opt. 37, 1784 (1998)]. We show that high-resolution (< or = 10 microm) x-ray backlighting systems using bent crystals can be more efficient than analogous point-projection imaging systems. Examples of bent-crystal-backlighting results that demonstrate 10-microm resolution over a 20-mm field of view are presented.

SELECTION OF CITATIONS
SEARCH DETAIL
...