Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-28314850

ABSTRACT

BACKGROUND: The occurrence of ventricular tachyarrhythmias seems to follow circadian, daily, and seasonal distributions. Our aim is to identify potential temporal patterns of electrical storm (ES), in which a cluster of ventricular tachycardias or ventricular fibrillation, negatively affects short- and long-term survival. METHODS AND RESULTS: The TEMPEST study (Circannual Pattern and Temperature-Related Incidence of Electrical Storm) is a patient-level, pooled analysis of previously published data sets. Study selection criteria included diagnosis of ES, absence of acute coronary syndrome as the arrhythmic trigger, and ≥10 patients included. At the end of the selection and collection processes, 5 centers had the data set from their article pooled into the present registry. Temperature data and sunrise and sunset hours were retrieved from Weather Underground, the largest weather database available online. Total sample included 246 patients presenting with ES (221 men; age: 65±9 years). Each ES episode included a median of 7 ventricular tachycardia/ventricular fibrillation episodes. Fifty-nine percent of patients experienced ES during daytime hours (P<0.001). The prevalence of ES was significantly higher during workdays, with Saturdays and Sundays registering the lowest rates of ES (10.4% and 7.2%, respectively, versus 16.5% daily mean from Monday to Friday; P<0.001). ES occurrence was significantly associated with increased monthly temperature range when compared with the month before (P=0.003). CONCLUSIONS: ES incidence is not homogenous over time but seems to have a clustered pattern, with a higher incidence during daytime hours and working days. ES is associated with an increase in monthly temperature variation. CLINICAL TRIAL REGISTRATION: https://www.crd.york.ac.uk. Unique identifier: CRD42013003744.


Subject(s)
Electrocardiography , Seasons , Tachycardia, Ventricular/epidemiology , Ventricular Fibrillation/epidemiology , Aged , Anti-Arrhythmia Agents/therapeutic use , Circadian Rhythm , Cluster Analysis , Comorbidity , Databases, Factual , Defibrillators, Implantable , Female , Humans , Incidence , Male , Middle Aged , Prognosis , Risk Assessment , Sampling Studies , Severity of Illness Index , Survival Rate , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Temperature , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/therapy
2.
Heart Rhythm ; 13(10): 1987-92, 2016 10.
Article in English | MEDLINE | ID: mdl-27291511

ABSTRACT

BACKGROUND: Electrical storm (ES) is defined as 3 or more episodes of ventricular fibrillation (VF) or ventricular tachycardia (VT) within 24 hours and is associated with increased cardiac and all-cause mortality. OBJECTIVE: The purpose of this study was to test whether aggressive implantable cardioverter-defibrillator (ICD) programming can be associated with ES. METHODS: The OBSERVational registry On long-term outcome of ICD patients (OBSERVO-ICD) is a multicenter, retrospective registry enrolling all consecutive patients undergoing ICD implantation from 2010 to 2012 in 5 Italian high-volume arrhythmia centers. Clinical history and risk factors were collected for all patients, as were ICD therapy-related variables such as detection zones and delays. The total number of arrhythmic episodes and therapies delivered by the ICD were collected through out-of-hospital visits and remote monitoring. RESULTS: The registry enrolled 1319 consecutive patients, of whom 62 (4.7%) experienced at least 1 ES during follow-up (median 39 months). Patients who experienced ES had a significantly lower VF detection zone (P = .002), more frequently had antitachycardia pacing therapies programmed off during capacitor charge (P = .001), and less frequently had an ICD set with delayed therapies for VT zones (P = .042) and VF zone (P = .036). Patients who experienced ES had a significantly higher incidence of death and heart failure-related death compared to patients with no ventricular arrhythmias and patients with unclustered VTs/VFs (P = .025 and P <.001, respectively). CONCLUSION: Patients with ES had a more aggressive ICD programming setup, including lower VF detection rates, shorter detection times, and no antitachycardia pacing therapies during capacitor charge. This kind of ICD programming potentially could increase the likelihood of ES and the related risk of death.


Subject(s)
Defibrillators, Implantable/adverse effects , Tachycardia, Ventricular , Ventricular Fibrillation , Aged , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/statistics & numerical data , Equipment Failure Analysis/statistics & numerical data , Female , Humans , Incidence , Italy/epidemiology , Male , Middle Aged , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/mortality , Ventricular Fibrillation/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...