Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 267
Filter
1.
Circ Cardiovasc Interv ; 17(5): e013302, 2024 May.
Article in English | MEDLINE | ID: mdl-38771909

ABSTRACT

Drug-coated balloons (DCBs) are specialized coronary devices comprised of a semicompliant balloon catheter with an engineered coating that allows the delivery of antiproliferative agents locally to the vessel wall during percutaneous coronary intervention. Although DCBs were initially developed more than a decade ago, their potential in coronary interventions has recently sparked renewed interest, especially in the United States. Originally designed to overcome the limitations of conventional balloon angioplasty and stenting, they aim to match or even improve upon the outcomes of drug-eluting stents without leaving a permanent implant. Presently, in-stent restenosis is the condition with the most robust evidence supporting the use of DCBs. DCBs provide improved long-term vessel patency compared with conventional balloon angioplasty and may be comparable to drug-eluting stents without the need for an additional stent layer, supporting their use as a first-line therapy for in-stent restenosis. Beyond the treatment of in-stent restenosis, DCBs provide an additional tool for de novo lesions for a strategy that avoids a permanent metal scaffold, which may be especially useful for the management of technically challenging anatomies such as small vessels and bifurcations. DCBs might also be advantageous for patients with high bleeding risk due to the decreased necessity for extended antiplatelet therapy, and in patients with diabetes and patients with diffuse disease to minimize long-stented segments. Further studies are crucial to confirm these broader applications for DCBs and to further validate safety and efficacy.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Cardiovascular Agents , Coated Materials, Biocompatible , Coronary Artery Disease , Coronary Restenosis , Humans , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Treatment Outcome , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/adverse effects , Equipment Design , Risk Factors , Vascular Patency , Drug-Eluting Stents
2.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726720

ABSTRACT

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Subject(s)
Consensus , Hemorrhage , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Hemorrhage/etiology , Risk Assessment , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
3.
JAMA Cardiol ; 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38630494

ABSTRACT

Importance: Although the results of A Study to Evaluate the Corvia Medical Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF II) trial were neutral overall, atrial shunt therapy demonstrated potential efficacy in responders (no latent pulmonary vascular disease and no cardiac rhythm management device). Post hoc analyses were conducted to evaluate the effect of shunt vs sham stratified by responder status. Objective: To evaluate the effect of atrial shunt vs sham control on cardiac structure/function in the overall study and stratified by responder status. Design, Setting, and Participants: This was a sham-controlled randomized clinical trial of an atrial shunt device in heart failure with preserved ejection fraction (HFpEF)/HF with mildly reduced EF (HFmrEF). Trial participants with evaluable echocardiography scans were recruited from 89 international medical centers. Data were analyzed from April 2023 to January 2024. Interventions: Atrial shunt device or sham control. Main Outcome Measures: Changes in echocardiographic measures from baseline to 1, 6, 12, and 24 months after index procedure. Results: The modified intention-to-treat analysis of the REDUCE LAP-HF II trial included 621 randomized patients (median [IQR] age, 72.0 [66.0-77.0] years; 382 female [61.5%]; shunt arm, 309 [49.8%]; sham control arm, 312 [50.2%]). Through 24 months, 212 of 217 patients (98%) in the shunt arm with evaluable echocardiograms had patent shunts. In the overall trial population, the shunt reduced left ventricular (LV) end-diastolic volume (mean difference, -5.65 mL; P <.001), left atrial (LA) minimal volume (mean difference, -2.8 mL; P =.01), and improved LV systolic tissue Doppler velocity (mean difference, 0.69 cm/s; P <.001) and LA emptying fraction (mean difference, 1.88 percentage units; P =.02) compared with sham. Shunt treatment also increased right ventricular (RV; mean difference, 9.58 mL; P <.001) and right atrial (RA; mean difference, 9.71 mL; P <.001) volumes but had no effect on RV systolic function, pulmonary artery pressure, or RA pressure compared with sham. In the shunt arm, responders had smaller increases in RV end-diastolic volume (mean difference, 5.71 mL vs 15.18 mL; interaction P =.01), RV end-systolic volume (mean difference, 1.58 mL vs 7.89 mL; interaction P =.002), and RV/LV ratio (mean difference, 0.07 vs 0.20; interaction P <.001) and larger increases in transmitral A wave velocity (mean difference, 5.08 cm/s vs -1.97 cm/s; interaction P =.02) compared with nonresponders randomized to the shunt, suggesting greater ability to accommodate shunted blood through the pulmonary circulation enabling LA unloading. Conclusions and Relevance: In this post hoc analysis of the REDUCE LAP-HF II trial, over 2 years of follow-up, atrial shunting led to reverse remodeling of left-sided chambers and increases in volume of right-sided chambers consistent with the shunt flow but no change in RV systolic function compared with sham. Changes in cardiac structure/function were more favorable in responders compared with nonresponders treated with the shunt, supporting the previously identified responder group hypothesis and mechanism, although further evaluation with longer follow-up is needed. Trial Registration: ClinicalTrials.gov Identifier: NCT03088033.

5.
Eur J Heart Fail ; 26(1): 177-189, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37989800

ABSTRACT

AIMS: Obesity is causally related to the development of heart failure with preserved ejection fraction (HFpEF) but complicates the diagnosis and treatment of this disorder. We aimed to determine the relationship between severity of obesity and clinical, echocardiographic and haemodynamic parameters in a large cohort of patients with documented HFpEF. METHODS AND RESULTS: The REDUCE LAP-HF II trial randomized 626 patients with ejection fraction ≥40% and exercise pulmonary capillary wedge pressure (PCWP) ≥25 mmHg to atrial shunt or sham procedure. We tested for associations between body mass index (BMI), clinical characteristics, cardiac structural and functional abnormalities, physical limitations, quality of life and outcomes with atrial shunt therapy. Overall, 60.9% of patients had BMI ≥30 kg/m2 . As the severity of obesity increased, symptoms (Kansas City Cardiomyopathy Questionnaire score) and 6-min walk distance worsened. More severe obesity was associated with lower natriuretic peptide levels despite more cardiac remodelling, higher cardiac filling pressures, and higher cardiac output. Lower cut points for E/e' were needed to identify elevated PCWP in more obese patients. Strain measurements in all four chambers were maintained as BMI increased. Pulmonary vascular resistance at rest and exercise decreased with higher BMI. Obesity was associated with more first and recurrent heart failure events. However, there was no significant interaction between obesity and treatment effects of the atrial shunt. CONCLUSIONS: Increasing severity of obesity was associated with greater cardiac remodelling, higher right and left ventricular filling pressures, higher cardiac output and increased subsequent heart failure events. Despite significant obesity, many HFpEF patients have preserved right heart and pulmonary vascular function and thus, may be appropriate candidates for atrial shunt therapy.


Subject(s)
Flavins , Heart Failure , Luciferases , Humans , Stroke Volume , Cardiac Catheterization , Ventricular Remodeling , Quality of Life , Heart Atria , Obesity/complications , Ventricular Function, Left
6.
Circulation ; 148(14): 1113-1126, 2023 10 03.
Article in English | MEDLINE | ID: mdl-37782695

ABSTRACT

The Shock Academic Research Consortium is a multi-stakeholder group, including representatives from the US Food and Drug Administration and other government agencies, industry, and payers, convened to develop pragmatic consensus definitions useful for the evaluation of clinical trials enrolling patients with cardiogenic shock, including trials evaluating mechanical circulatory support devices. Several in-person and virtual meetings were convened between 2020 and 2022 to discuss the need for developing the standardized definitions required for evaluation of mechanical circulatory support devices in clinical trials for cardiogenic shock patients. The expert panel identified key concepts and topics by performing literature reviews, including previous clinical trials, while recognizing current challenges and the need to advance evidence-based practice and statistical analysis to support future clinical trials. For each category, a lead (primary) author was assigned to perform a literature search and draft a proposed definition, which was presented to the subgroup. These definitions were further modified after feedback from the expert panel meetings until a consensus was reached. This manuscript summarizes the expert panel recommendations focused on outcome definitions, including efficacy and safety.


Subject(s)
Heart Valve Prosthesis Implantation , Heart-Assist Devices , Humans , Shock, Cardiogenic/therapy , Shock, Cardiogenic/surgery , Research Design
7.
JACC Heart Fail ; 11(10): 1351-1362, 2023 10.
Article in English | MEDLINE | ID: mdl-37480877

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is a common comorbidity in patients with heart failure with preserved ejection fraction (HFpEF) and in heart failure with mildly reduced ejection fraction (HFmrEF). OBJECTIVES: This study sought to describe AF burden and its clinical impact among individuals with HFpEF and HFmrEF who participated in a randomized clinical trial of atrial shunt therapy (REDUCE LAP-HF II [A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure]) and to evaluate the effect of atrial shunt therapy on AF burden. METHODS: Study investigators characterized AF burden among patients in the REDUCE LAP-HF II trial by using ambulatory cardiac patch monitoring at baseline (median patch wear time, 6 days) and over a 12-month follow-up (median patch wear time, 125 days). The investigators determined the association of baseline AF burden with long-term clinical events and examined the effect of atrial shunt therapy on AF burden over time. RESULTS: Among 367 patients with cardiac monitoring data at baseline and follow-up, 194 (53%) had a history of AF or atrial flutter (AFL), and median baseline AF burden was 0.012% (IQR: 0%-1.3%). After multivariable adjustment, baseline AF burden ≥0.012% was significantly associated with heart failure (HF) events (HR: 2.00; 95% CI: 1.17-3.44; P = 0.01) both with and without a history of AF or AFL (P for interaction = 0.68). Adjustment for left atrial reservoir strain attenuated the baseline AF burden-HF event association (HR: 1.71; 95% CI: 0.93-3.14; P = 0.08). Of the 367 patients, 141 (38%) had patch-detected AF during follow-up without a history of AF or AFL. Atrial shunt therapy did not change AF incidence or burden during follow-up. CONCLUSIONS: In HFpEF and HFmrEF, nearly 40% of patients have subclinical AF by 1 year. Baseline AF burden, even at low levels, is associated with HF events. Atrial shunt therapy does not affect AF incidence or burden. (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure [REDUCE LAP-HF II]; NCT03088033).


Subject(s)
Atrial Fibrillation , Heart Failure , Humans , Atrial Fibrillation/epidemiology , Stroke Volume , Heart Atria , Prosthesis Implantation , Prognosis
9.
JACC Heart Fail ; 11(8 Pt 2): 1103-1117, 2023 08.
Article in English | MEDLINE | ID: mdl-36939661

ABSTRACT

BACKGROUND: Many patients with heart failure and preserved ejection fraction have no overt volume overload and normal resting left atrial (LA) pressure. OBJECTIVES: This study sought to characterize patients with normal resting LA pressure (pulmonary capillary wedge pressure [PCWP] <15 mm Hg) but exercise-induced left atrial hypertension (EILAH). METHODS: The REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc. IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure) trial randomized 626 patients with ejection fraction ≥40% and exercise PCWP ≥25 mm Hg to atrial shunt or sham procedure. The primary trial outcome, a hierarchical composite of death, heart failure hospitalization, intensification of diuretics, and change in health status was compared between patients with EILAH and those with heart failure and resting left atrial hypertension (RELAH). RESULTS: Patients with EILAH (29%) had similar symptom severity, but lower natriuretic peptide levels, higher 6-minute walk distance, less atrial fibrillation, lower left ventricular mass, smaller LA volumes, lower E/e', and better LA strain. PCWP was lower at rest, but had a larger increase with exercise in EILAH. Neither group as a whole had a significant effect from shunt therapy vs sham. Patients with EILAH were more likely to have characteristics associated with atrial shunt responsiveness (peak exercise pulmonary vascular resistance <1.74 WU) and no pacemaker (63% vs 46%; P < 0.001). The win ratio for the primary outcome was 1.56 (P = 0.08) in patients with EILAH and 1.51 (P = 0.04) in those with RELAH when responder characteristics were present. CONCLUSIONS: Patients with EILAH had similar symptom severity but less advanced myocardial and pulmonary vascular disease. This important subgroup may be difficult to diagnose without invasive exercise hemodynamics, but it has characteristics associated with favorable response to atrial shunt therapy. (A Study to Evaluate the Corvia Medical, Inc. IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure [REDUCE LAP-HF TRIAL II]; NCT03088033).


Subject(s)
Atrial Fibrillation , Heart Failure , Hypertension , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/therapy , Cardiac Catheterization , Heart Failure/complications , Heart Failure/therapy , Heart Failure/diagnosis , Stroke Volume/physiology , Ventricular Function, Left
10.
J Vasc Surg ; 77(6): 1685-1692.e2, 2023 06.
Article in English | MEDLINE | ID: mdl-36736864

ABSTRACT

OBJECTIVE: The Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial, a multicenter randomized controlled trial with 947 patients, concluded that there was no benefit of renal artery stenting (RAS) over medical therapy. However, patients with chronic kidney disease (CKD) were not analyzed separately in the CORAL trial. CKD is a risk factor for cardiovascular and renal morbidity. We hypothesized that improved renal function after RAS would be associated with increased long-term survival and a lower risk of cardiovascular and renal events in patients with CKD. METHODS: This post hoc analysis of the CORAL trial included 842 patients with CKD stages 2 to 4 at baseline who were randomized to optimal medical therapy alone (OMT; n = 432) or RAS plus OMT (RAS + OMT; n = 410). Patients were categorized as responders or nonresponders based on the change in the estimated glomerular filtration rate (eGFR) from baseline to last follow-up (median, 3.6 years; interquartile range, 2.6-4.6 years). Responders were defined by a 20% or greater increase in eGFR from baseline; all others were designated as nonresponders. Event-free survival was defined as freedom from death and multiple cardiovascular and renal complications. Event-free survival was analyzed using the Kaplan-Meier method and log-rank test. Multivariable Cox proportional hazards regression analysis was used to identify independent predictors of event-free survival. RESULTS: The RAS + OMT group had a higher proportion of patients with improved renal function (≥20% increase in eGFR over baseline), compared with the OMT group (25.6% vs 17.1%; P = .003). However, event-free survival was no different for the two cohorts (P = .18 by the log-rank test). Multivariable Cox proportional hazards regression analysis identified four variables that independently correlated with event-free survival for the stented cohort. Higher preoperative eGFR (hazard ratio, 0.98; 95% confidence interval [CI], 0.96-0.99; P = .002) and being a responder to stenting (hazard ratio, 0.49; 95% CI, 0.26-0.95; P = .033) increased event-free survival, whereas a history of congestive heart failure (hazard ratio, 2.52; 95% CI, 1.46-4.35; P < .001) and a higher preoperative systolic BP (hazard ratio, 1.02; 95% CI, 1.01-1.03; P = .002) decreased event-free survival. Within the stented group, 105 of 410 patients (25.6%) were responders. Event-free survival was superior for responders, compared with nonresponders (P = .009 by log-rank test). The only independent preoperative negative predictor of improved renal function after stenting was diabetes (odds ratio, 0.37; 95% CI, 0.16-0.84; P = .017), which decreased the probability of improved renal function after RAS + OMT. A subset of patients (23.4%) after RAS had worsened renal function, but OMT alone produced an equivalent incidence of worsened renal function. An increased urine albumin/creatinine ratio was an independent predictor of worsened renal function after RAS. CONCLUSIONS: CORAL participants who demonstrated improved kidney function after RAS + OMT demonstrated improved event-free survival. This finding reinforces the need for predictors of outcome to guide patient selection for RAS.


Subject(s)
Atherosclerosis , Renal Insufficiency, Chronic , Humans , Renal Artery , Progression-Free Survival , Kidney/blood supply , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/therapy , Atherosclerosis/complications , Atherosclerosis/therapy , Atherosclerosis/pathology , Risk Factors , Glomerular Filtration Rate , Treatment Outcome
11.
EuroIntervention ; 19(10): e807-e831, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-35583108

ABSTRACT

The Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods. Considering the complexity of bifurcation lesions and their evaluation, detailed instructions and technical aspects for site and core laboratory analysis of bifurcation lesions are also reported. The recommendations included within this consensus will facilitate pooled analyses and the effective comparison of data in the future, improving the clinical relevance of trials in bifurcation lesions, and the quality of care in this subset of patients.


Subject(s)
Coronary Artery Disease , Heart Valve Prosthesis Implantation , Humans , United States , Heart , Heart Valve Prosthesis Implantation/methods , Europe , Asia , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Treatment Outcome , Coronary Angiography
13.
JACC Cardiovasc Interv ; 15(18): 1852-1860, 2022 09 26.
Article in English | MEDLINE | ID: mdl-36137689

ABSTRACT

BACKGROUND: Randomized trials have demonstrated the superiority of ultrathin strut drug-eluting stents compared with alternative stent designs. Whether these differences persist over late-term follow-up is uncertain. OBJECTIVES: This study sought to compare late-term (5-year) clinical outcomes among patients treated with ultrathin strut (60 µm) bioresorbable polymer sirolimus-eluting stents (BP SES) and thin strut (81 µm) durable polymer everolimus-eluting stents (DP EES). METHODS: BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects with Up to Three De Novo or Restenotic Coronary Artery Lesions V) was an international, 2:1 randomized trial comparing percutaneous coronary intervention with ultrathin strut BP SES versus thin strut DP EES regarding the primary endpoint of 12-month target lesion failure (TLF). Prespecified outcomes through 5 years were assessed. RESULTS: Among 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 5-year rates of TLF were 12.3% for BP SES and 15.3% for DP EES (P = 0.108). Revascularization with BP SES was associated with a significantly lower target vessel-related myocardial infarction (6.6% vs 10.3%, P = 0.015) and late/very late definite/probable stent thrombosis (0.3% vs 1.6%, P = 0.021). Ischemia-driven target lesion revascularization was numerically but not significantly lower with BP SES (5.9% vs 7.7%, P = 0.202). Cardiac death rates were 2.6% versus 1.9% (P = 0.495) for BP SES and DP EES, respectively. CONCLUSIONS: In a large, randomized trial, TLF and the individual outcomes of cardiac death and target lesion revascularization at 5 years were similar among patients treated with BP SES versus DP EES. Both target vessel-related myocardial infarction and late/very late definite/probable stent thrombosis were significantly lower with BP SES. These results confirm the durability of safety and the effectiveness of percutaneous coronary intervention with ultrathin BP SES.


Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Absorbable Implants , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/etiology , Coronary Artery Disease/therapy , Death , Everolimus/adverse effects , Humans , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Polymers , Prospective Studies , Prosthesis Design , Sirolimus/adverse effects , Treatment Outcome
14.
J Am Coll Cardiol ; 80(1): 63-88, 2022 07 05.
Article in English | MEDLINE | ID: mdl-35597684

ABSTRACT

The Bifurcation Academic Research Consortium (Bif-ARC) project originated from the need to overcome the paucity of standardization and comparability between studies involving bifurcation coronary lesions. This document is the result of a collaborative effort between academic research organizations and the most renowned interventional cardiology societies focused on bifurcation lesions in Europe, the United States, and Asia. This consensus provides standardized definitions for bifurcation lesions; the criteria to judge the side branch relevance; the procedural, mechanistic, and clinical endpoints for every type of bifurcation study; and the follow-up methods. Considering the complexity of bifurcation lesions and their evaluation, detailed instructions and technical aspects for site and core laboratory analysis of bifurcation lesions are also reported. The recommendations included within this consensus will facilitate pooled analyses and the effective comparison of data in the future, improving the clinical relevance of trials in bifurcation lesions, and the quality of care in this subset of patients.


Subject(s)
Coronary Artery Disease , Heart Valve Prosthesis Implantation , Asia , Cardiac Catheterization/methods , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Artery Disease/therapy , Europe , Heart , Heart Valve Prosthesis Implantation/methods , Humans , Treatment Outcome , United States/epidemiology
16.
Circulation ; 145(21): 1592-1604, 2022 05 24.
Article in English | MEDLINE | ID: mdl-35354306

ABSTRACT

BACKGROUND: In REDUCE LAP-HF II (A Study to Evaluate the Corvia Medical, Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients With Heart Failure), implantation of an atrial shunt device did not provide overall clinical benefit for patients with heart failure with preserved or mildly reduced ejection fraction. However, prespecified analyses identified differences in response in subgroups defined by pulmonary artery systolic pressure during submaximal exercise, right atrial volume, and sex. Shunt implantation reduces left atrial pressures but increases pulmonary blood flow, which may be poorly tolerated in patients with pulmonary vascular disease (PVD). On the basis of these results, we hypothesized that patients with latent PVD, defined as elevated pulmonary vascular resistance during exercise, might be harmed by shunt implantation, and conversely that patients without PVD might benefit. METHODS: REDUCE LAP-HF II enrolled 626 patients with heart failure, ejection fraction ≥40%, exercise pulmonary capillary wedge pressure ≥25 mm Hg, and resting pulmonary vascular resistance <3.5 Wood units who were randomized 1:1 to atrial shunt device or sham control. The primary outcome-a hierarchical composite of cardiovascular death, nonfatal ischemic stroke, recurrent HF events, and change in health status-was analyzed using the win ratio. Latent PVD was defined as pulmonary vascular resistance ≥1.74 Wood units (highest tertile) at peak exercise, measured before randomization. RESULTS: Compared with patients without PVD (n=382), those with latent PVD (n=188) were older, had more atrial fibrillation and right heart dysfunction, and were more likely to have elevated left atrial pressure at rest. Shunt treatment was associated with worse outcomes in patients with PVD (win ratio, 0.60 [95% CI, 0.42, 0.86]; P=0.005) and signal of clinical benefit in patients without PVD (win ratio, 1.31 [95% CI, 1.02, 1.68]; P=0.038). Patients with larger right atrial volumes and men had worse outcomes with the device and both groups were more likely to have pacemakers, heart failure with mildly reduced ejection fraction, and increased left atrial volume. For patients without latent PVD or pacemaker (n=313; 50% of randomized patients), shunt treatment resulted in more robust signal of clinical benefit (win ratio, 1.51 [95% CI, 1.14, 2.00]; P=0.004). CONCLUSIONS: In patients with heart failure with preserved or mildly reduced ejection fraction, the presence of latent PVD uncovered by invasive hemodynamic exercise testing identifies patients who may worsen with atrial shunt therapy, whereas those without latent PVD may benefit.


Subject(s)
Cardiac Catheterization , Heart Atria , Heart Failure , Vascular Diseases , Cardiac Catheterization/instrumentation , Female , Heart Atria/surgery , Heart Failure/surgery , Humans , Male , Pulmonary Circulation , Stroke Volume , Treatment Outcome , Vascular Diseases/complications
17.
Circulation ; 145(11): 847-863, 2022 03 15.
Article in English | MEDLINE | ID: mdl-35286164

ABSTRACT

The clinical implications of hypertension in addition to a high prevalence of both uncontrolled blood pressure and medication nonadherence promote interest in developing device-based approaches to hypertension treatment. The expansion of device-based therapies and ongoing clinical trials underscores the need for consistency in trial design, conduct, and definitions of clinical study elements to permit trial comparability and data poolability. Standardizing methods of blood pressure assessment, effectiveness measures beyond blood pressure alone, and safety outcomes are paramount. The Hypertension Academic Research Consortium (HARC) document represents an integration of evolving evidence and consensus opinion among leading experts in cardiovascular medicine and hypertension research with regulatory perspectives on clinical trial design and methodology. The HARC document integrates the collective information among device-based therapies for hypertension to better address existing challenges and identify unmet needs for technologies proposed to treat the world's leading cause of death and disability. Consistent with the Academic Research Consortium charter, this document proposes pragmatic consensus clinical design principles and outcomes definitions for studies aimed at evaluating device-based hypertension therapies.


Subject(s)
Hypertension , Clinical Trials as Topic , Consensus , Humans , Hypertension/diagnosis , Hypertension/therapy
18.
Lancet ; 399(10330): 1130-1140, 2022 03 19.
Article in English | MEDLINE | ID: mdl-35120593

ABSTRACT

BACKGROUND: Placement of an interatrial shunt device reduces pulmonary capillary wedge pressure during exercise in patients with heart failure and preserved or mildly reduced ejection fraction. We aimed to investigate whether an interatrial shunt can reduce heart failure events or improve health status in these patients. METHODS: In this randomised, international, blinded, sham-controlled trial performed at 89 health-care centres, we included patients (aged ≥40 years) with symptomatic heart failure, an ejection fraction of at least 40%, and pulmonary capillary wedge pressure during exercise of at least 25 mm Hg while exceeding right atrial pressure by at least 5 mm Hg. Patients were randomly assigned (1:1) to receive either a shunt device or sham procedure. Patients and outcome assessors were masked to randomisation. The primary endpoint was a hierarchical composite of cardiovascular death or non-fatal ischemic stroke at 12 months, rate of total heart failure events up to 24 months, and change in Kansas City Cardiomyopathy Questionnaire overall summary score at 12 months. Pre-specified subgroup analyses were conducted for the heart failure event endpoint. Analysis of the primary endpoint, all other efficacy endpoints, and safety endpoints was conducted in the modified intention-to-treat population, defined as all patients randomly allocated to receive treatment, excluding those found to be ineligible after randomisation and therefore not treated. This study is registered with ClinicalTrials.gov, NCT03088033. FINDINGS: Between May 25, 2017, and July 24, 2020, 1072 participants were enrolled, of whom 626 were randomly assigned to either the atrial shunt device (n=314) or sham procedure (n=312). There were no differences between groups in the primary composite endpoint (win ratio 1·0 [95% CI 0·8-1·2]; p=0·85) or in the individual components of the primary endpoint. The prespecified subgroups demonstrating a differential effect of atrial shunt device treatment on heart failure events were pulmonary artery systolic pressure at 20W of exercise (pinteraction=0·002 [>70 mm Hg associated with worse outcomes]), right atrial volume index (pinteraction=0·012 [≥29·7 mL/m2, worse outcomes]), and sex (pinteraction=0·02 [men, worse outcomes]). There were no differences in the composite safety endpoint between the two groups (n=116 [38%] for shunt device vs n=97 [31%] for sham procedure; p=0·11). INTERPRETATION: Placement of an atrial shunt device did not reduce the total rate of heart failure events or improve health status in the overall population of patients with heart failure and ejection fraction of greater than or equal to 40%. FUNDING: Corvia Medical.


Subject(s)
Cardiac Catheterization , Heart Failure , Adult , Cardiac Catheterization/instrumentation , Flavins , Heart Atria/surgery , Heart Failure/physiopathology , Humans , Luciferases , Male , Stroke Volume
19.
Cardiovasc Revasc Med ; 41: 105-112, 2022 08.
Article in English | MEDLINE | ID: mdl-35045941

ABSTRACT

BACKGROUND: Guidelines recommend individualization of dual antiplatelet therapy (DAPT) duration. Whether to guide decisions based on bleeding risk, ischemic risk or a combination is not known. AIMS: To compare a bleeding prediction model, an ischemic prediction model, and the DAPT score in guiding DAPT duration. METHODS: 11,648 patients in the DAPT Study were categorized into higher and lower risk using a bleeding model, an ischemic model, and the DAPT score. Effect of 30 vs. 12 months of DAPT on bleeding events, ischemic events, and the combination (net-adverse clinical events [NACE]) was assessed. RESULTS: Among patients stratified with the bleeding model, 30 vs. 12 months of DAPT resulted in similar ischemic and bleeding event rates. With the ischemic model, however, higher risk patients had a greater reduction in ischemic events with extended duration of DAPT (difference in risk differences [DRD]: -2.6%, 95% CI: -3.9 to -1.3%; p < 0.01), and a smaller increase in bleeding (DRD: -1.0%, 95% CI: -2.1-0.0%; p = 0.04). Similarly, high DAPT score patients had a greater reduction in ischemic events with extended DAPT duration (DRD: -2.4%, 95%: CI: -3.6 to -1.1%; p < 0.01) and a smaller increase in bleeding (DRD: -1.2%, 95%: CI: -2.2-0.0%; p = 0.02). Although NACE was similar for bleeding risk groups, NACE was significantly reduced with extended DAPT in the higher ischemic risk and high DAPT score groups. CONCLUSIONS: In this low-bleeding risk population, stratifying patients based on predicted ischemic risk and the DAPT score best discerned benefit versus harm of extended DAPT duration on ischemic events, bleeding events, and NACE. CONDENSED ABSTRACT: Duration of dual antiplatelet therapy (DAPT) should be guided by an individualized risk assessment. Bleeding risk tools have emerged to identify patients at high bleeding risk for whom truncated DAPT therapy may be safest. In a lower bleeding risk population, however, whether DAPT duration should be guided by bleeding risk, ischemic risk, or a combination is unknown. In this analysis, implementation of a score based on ischemic risk prediction and the DAPT score (a combination of ischemic and bleeding risk) best predicted ischemic events, bleeding events, and net-adverse clinical events (NACE).


Subject(s)
Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors , Dinucleoside Phosphates , Drug Therapy, Combination , Dual Anti-Platelet Therapy/adverse effects , Hemorrhage/etiology , Humans , Ischemia/diagnosis , Ischemia/drug therapy , Percutaneous Coronary Intervention/adverse effects , Platelet Aggregation Inhibitors/adverse effects , Treatment Outcome
20.
Cardiovasc Revasc Med ; 41: 76-80, 2022 08.
Article in English | MEDLINE | ID: mdl-35045942

ABSTRACT

BACKGROUND/PURPOSE: The COBRA Polyzene F™ NanoCoated Coronary Stent System (PzF coated stent) stent demonstrated favorable clinical outcomes at 9 months but late results have not been reported. We sought to assess the late safety and effectiveness of the PzF coated stent for treatment of de novo coronary artery lesions. METHODS: Patients with de novo coronary artery lesions meeting eligibility criteria were enrolled in a non-randomized, prospective clinical trial and followed for 5 years. The primary endpoint was target vessel failure (TVF, cardiac death, myocardial infarction [MI], or clinically-driven target vessel revascularization [TVR]) at 9 months. Secondary endpoints included major adverse clinical events (MACE, cardiac death, MI, or clinically driven TLR), clinically driven target lesion revascularization (TLR) and definite or probable stent thrombosis during 5-year follow-up. Endpoints at 5 years were analyzed as cumulative incidence accounting for competing risk of death. RESULTS: Of 296 enrolled patients, 290 (98%) were evaluable at 5 years. By 5 years, MACE had occurred in 61 (21.3%), cardiac death in 11 (4.2%), MI in 25 (8.6%), and TLR in 34 (12.0%) subjects. Between follow-up years 1 and 5, a first MACE occurred in 17 (6.2%), including 10 (4.0%) cardiac death, 4 (1.6%) MI, and 7 (2.9%) TLR events. There were no definite or probable stent thromboses. CONCLUSIONS: The PzF coated stent demonstrated continued safety and effectiveness through 5 years with low to very low incident rates of MACE, MI, TLR and stent thrombosis between 1 and 5 years after stent placement.


Subject(s)
Coronary Artery Disease , Myocardial Infarction , Percutaneous Coronary Intervention , Thrombosis , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Death , Humans , Myocardial Infarction/complications , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Prosthesis Design , Stents/adverse effects , Thrombosis/etiology , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...