Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Biosensors (Basel) ; 11(6)2021 Jun 07.
Article in English | MEDLINE | ID: mdl-34200338

ABSTRACT

The detection of cancer antigens is a major aim of cancer research in order to develop better patient management through early disease detection. Many cancers including prostate, lung, and ovarian secrete a protein disulfide isomerase protein named AGR2 that has been previously detected in urine and plasma using mass spectrometry. Here we determine whether a previously developed monoclonal antibody targeting AGR2 can be adapted from an indirect two-site ELISA format into a direct detector using solid-phase printed gold electrodes. The screen-printed gold electrode was surface functionalized with the anti-AGR2 specific monoclonal antibody. The interaction of the recombinant AGR2 protein and the anti-AGR2 monoclonal antibody functionalized electrode changed its electrochemical impedance spectra. Nyquist diagrams were obtained after incubation in an increasing concentration of purified AGR2 protein with a range of concentrations from 0.01 fg/mL to 10 fg/mL. In addition, detection of the AGR2 antigen can be achieved from cell lysates in medium or artificial buffer. These data highlight the utility of an AGR2-specific monoclonal antibody that can be functionalized onto a gold printed electrode for a one-step capture and quantitation of the target antigen. These platforms have the potential for supporting methodologies using more complex bodily fluids including plasma and urine for improved cancer diagnostics.


Subject(s)
Biosensing Techniques , Mucoproteins/analysis , Oncogene Proteins/analysis , Antibodies, Monoclonal , Electrochemical Techniques , Electrodes , Gold , Humans , Limit of Detection , Metal Nanoparticles , Neoplasms
2.
Sensors (Basel) ; 20(18)2020 Sep 17.
Article in English | MEDLINE | ID: mdl-32957594

ABSTRACT

Streptococcus pyogenes is a known cause of a wide spectrum of diseases, from mild and acute to severe invasive infections. This paper concerns the development of a novel impedimetric biosensor for the detection of the mentioned human pathogen. The proposed biosensor is a gold disk electrode modified with commercially available antibodies attached to the surface of the electrode by carbodiimide chemistry. The conducted tests confirmed the specificity of the antibodies used, which was also demonstrated by the results obtained during the detection of S. pyogenes using electrochemical impedance spectroscopy. The developed sensor successfully detected the presence of S. pyogenes in the sample and the detection limit was calculated as 9.3 cfu/mL. The results obtained show a wide linear range for verified concentrations of this pathogen in a sample from 4.2 × 102 to 4.2 × 106 cfu/mL. Furthermore, the optimal experimentally determined time required to perform pathogen detection in the sample was estimated as 3 min, and the test did not lead to the degradation of the sample.


Subject(s)
Biosensing Techniques , Gold , Streptococcus pyogenes , Dielectric Spectroscopy , Electrochemical Techniques , Electrodes , Humans , Limit of Detection
3.
Sensors (Basel) ; 19(24)2019 Dec 09.
Article in English | MEDLINE | ID: mdl-31835291

ABSTRACT

The present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA). Sensor development was characterized by cyclic voltammetry (CV) and antigen detection by electrochemical impedance spectroscopy (EIS) measurements. Seven analyzed strains of Psl were verified as positive by the reference method (PCR) and this immunoassay, proving sensor specificity. Label-free electrochemical detection was in the linear range 1 × 103-1.2 × 105 CFU/mL (colony-forming unit) with an R2 coefficient of 0.992 and a detection limit (LOD) of 337 CFU/mL. The sensor did not interfere with negative probes like buffers and other bacteria. The assay was proven to be fast (10 min detection) and easy in preparation. The advantage was the simplicity and availability of the verified analyte (whole bacteria) as the method does not require sample pretreatment (e.g., DNA isolation). EIS biosensing technique was chosen as one of the simplest and most sensitive with the least destructive influence on the probes compared to other electrochemical methods.


Subject(s)
Biosensing Techniques , Dielectric Spectroscopy , Plant Diseases/microbiology , Pseudomonas syringae/isolation & purification , Antibodies/chemistry , Electrodes , Gold/chemistry , Plant Diseases/genetics , Pseudomonas syringae/genetics , Pseudomonas syringae/pathogenicity
4.
Spectrochim Acta A Mol Biomol Spectrosc ; 222: 117226, 2019 Nov 05.
Article in English | MEDLINE | ID: mdl-31181504

ABSTRACT

Six novel amino acid chromophores were synthesized and their spectroscopic, acid-base, and electrochemical properties are discussed in this work. In studied compounds, selected amino acid residues (l-Aspartic acid, l-Glutamic acid, l-Glutamine, l-Histidine, l-Lysine, l-Arginine) are attached to the 1-(piperazine) 9,10-anthraquinone skeleton via the amide bond between the carboxyl group of amino acid and nitrogen atom of the piperazine ring. All derivatives have been characterized using a variety of spectroscopic techniques (mass spectrometry, 1HNMR, UV-Vis, IR spectroscopy), acid-base (electrochemical and UV-Vis) titrations, and cyclic voltammetry methods. Basing on observed experimental effects, supported by quantum chemical simulations, the structure-properties links were established. They are indicative of the specific interactions within and/or in-between amino acid side groups, which are prone to form both, intra- and intermolecular hydrogen bonds as well as electrostatic interactions with the anthraquinone system.


Subject(s)
Amino Acids/chemistry , Anthraquinones/chemistry , Coloring Agents/chemistry , Amino Acids/chemical synthesis , Anthraquinones/chemical synthesis , Coloring Agents/chemical synthesis , Electrochemical Techniques , Hydrogen Bonding , Models, Molecular , Protons , Spectrophotometry, Ultraviolet
5.
Biosensors (Basel) ; 8(4)2018 Oct 18.
Article in English | MEDLINE | ID: mdl-30340339

ABSTRACT

The basic affairs connected to the influenza virus were reviewed in the article, highlighting the newest trends in its diagnostic methods. Awareness of the threat of influenza arises from its ability to spread and cause a pandemic. The undiagnosed and untreated viral infection can have a fatal effect on humans. Thus, the early detection seems pivotal for an accurate treatment, when vaccines and other contemporary prevention methods are not faultless. Public health is being attacked with influenza containing new genes from a genetic assortment between animals and humankind. Unfortunately, the population does not have immunity for mutant genes and is attacked in every viral outbreak season. For these reasons, fast and accurate devices are in high demand. As currently used methods like Rapid Influenza Diagnostic Tests lack specificity, time and cost-savings, new methods are being developed. In the article, various novel detection methods, such as electrical and optical were compared. Different viral elements used as detection targets and analysis parameters, such as sensitivity and specificity, were presented and discussed.


Subject(s)
Influenza, Human/diagnosis , Influenza, Human/virology , Orthomyxoviridae/pathogenicity , Animals , Electrochemistry , Enzyme-Linked Immunosorbent Assay , Humans , Polymerase Chain Reaction
SELECTION OF CITATIONS
SEARCH DETAIL
...