Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
Add more filters










Publication year range
1.
eNeuro ; 11(6)2024 Jun.
Article in English | MEDLINE | ID: mdl-38844346

ABSTRACT

In measurement, a reference frame is needed to compare the measured object to something already known. This raises the neuroscientific question of which reference frame is used by humans when exploring the environment. Previous studies suggested that, in touch, the body employed as measuring tool also serves as reference frame. Indeed, an artificial modification of the perceived dimensions of the body changes the tactile perception of external object dimensions. However, it is unknown if such a change in tactile perception would occur when the body schema is modified through the illusion of owning a limb altered in size. Therefore, employing a virtual hand illusion paradigm with an elongated forearm of different lengths, we systematically tested the subjective perception of distance between two points [tactile distance perception (TDP) task] on the corresponding real forearm following the illusion. Thus, the TDP task is used as a proxy to gauge changes in the body schema. Embodiment of the virtual arm was found significantly greater after the synchronous visuotactile stimulation condition compared with the asynchronous one, and the forearm elongation significantly increased the TDP. However, we did not find any link between the visuotactile-induced ownership over the elongated arm and TDP variation, suggesting that vision plays the main role in the modification of the body schema. Additionally, significant effect of elongation found on TDP but not on proprioception suggests that these are affected differently by body schema modifications. These findings confirm the body schema malleability and its role as a reference frame in touch.


Subject(s)
Distance Perception , Illusions , Touch Perception , Virtual Reality , Humans , Female , Male , Touch Perception/physiology , Young Adult , Adult , Illusions/physiology , Distance Perception/physiology , Proprioception/physiology , Body Image , Forearm/physiology
2.
Clin Neurophysiol ; 156: 98-105, 2023 12.
Article in English | MEDLINE | ID: mdl-37918223

ABSTRACT

OBJECTIVE: To evaluate cortical circuits and excitability of the motor cortex in the hemisphere contralateral to the affected (AH) and to the unaffected arm (UH), in upper limb amputees. METHODS: Motor evoked potentials (MEP) were recorded in 17 subjects who had upper limb amputation: 11 trans-radial (TR) and 6 trans-humeral (TH). Motor thresholds (MT), short interval intracortical inhibition (SICI), and interhemispheric inhibition (IHI) in the available arm muscles of the stump were evaluated. RESULTS: There was no significant difference in MT between hemispheres. SICI was preserved in TR but not in TH group. Additionally, in the TR group, the MEP amplitudes in AH were higher than in UH. A significant IHI was observed in the whole sample but not in each hemisphere or patient group. CONCLUSIONS: In our population of TR amputees, we found increased corticospinal excitability in the AH with preserved intracortical inhibition. This finding was not observed in the TH population. SIGNIFICANCE: Understanding the changes in intracortical excitability in amputees may enhance knowledge of the functional reorganization of the brain in the post-amputation phase, bringing useful information for prosthetic rehabilitation.


Subject(s)
Amputees , Motor Cortex , Humans , Arm , Transcranial Magnetic Stimulation , Amputation, Surgical , Evoked Potentials, Motor/physiology , Neural Inhibition/physiology
3.
J Neuroeng Rehabil ; 20(1): 118, 2023 09 09.
Article in English | MEDLINE | ID: mdl-37689701

ABSTRACT

Proprioception plays a key role in moving our body dexterously and effortlessly. Nevertheless, the majority of investigations evaluating the benefits of providing supplemental feedback to prosthetics users focus on delivering touch restitution. These studies evaluate the influence of touch sensation in an attempt to improve the controllability of current robotic devices. Contrarily, investigations evaluating the capabilities of proprioceptive supplemental feedback have yet to be comprehensively analyzed to the same extent, marking a major gap in knowledge within the current research climate. The non-invasive strategies employed so far to restitute proprioception are reviewed in this work. In the absence of a clearly superior strategy, approaches employing vibrotactile, electrotactile and skin-stretch stimulation achieved better and more consistent results, considering both kinesthetic and grip force information, compared with other strategies or any incidental feedback. Although emulating the richness of the physiological sensory return through artificial feedback is the primary hurdle, measuring its effects to eventually support the integration of cumbersome and energy intensive hardware into commercial prosthetic devices could represent an even greater challenge. Thus, we analyze the strengths and limitations of previous studies and discuss the possible benefits of coupling objective measures, like neurophysiological parameters, as well as measures of prosthesis embodiment and cognitive load with behavioral measures of performance. Such insights aim to provide additional and collateral outcomes to be considered in the experimental design of future investigations of proprioception restitution that could, in the end, allow researchers to gain a more detailed understanding of possibly similar behavioral results and, thus, support one strategy over another.


Subject(s)
Artificial Limbs , Humans , Proprioception , Kinesthesis , Neurophysiology , Pain Management
4.
Neurosci Biobehav Rev ; 153: 105351, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37544389

ABSTRACT

Our interaction with the world rests on the knowledge that we are a body in space and time, which can interact with the environment. This awareness is usually referred to as sense of embodiment. For the good part of the past 30 years, the rubber hand illusion (RHI) has been a prime tool to study embodiment in healthy and people with a variety of clinical conditions. In this paper, we provide a critical overview of this research with a focus on the RHI paradigm as a tool to study prothesis embodiment in individuals with amputation. The RHI relies on well-documented multisensory integration mechanisms based on sensory precision, where parietal areas are involved in resolving the visuo-tactile conflict, and premotor areas in updating the conscious bodily representation. This mechanism may be transferable to prosthesis ownership in amputees. We discuss how these results might transfer to technological development of sensorised prostheses, which in turn might progress the acceptability by users.

5.
Front Neurorobot ; 17: 1130770, 2023.
Article in English | MEDLINE | ID: mdl-37009638

ABSTRACT

Introduction: Robotic therapy allow to propose sessions of controlled and identical exercises, customizing settings, and characteristics on the individual patient. The effectiveness of robotic assisted therapy is still under study and the use of robots in clinical practice is still limited. Moreover, the possibility of treatment at home allows to reduce the economic costs and time to be borne by the patient and the caregiver and is a valid tool during periods of pandemic such as covid. The aim of this study is to assess whether a robotic home-based treatment rehabilitation using the iCONE robotic device has effects on a stroke population, despite the chronic condition of patients involved and the absence of a therapist next to the patient while performing the exercises. Materials and methods: All patients underwent an initial (T0) and final (T1) assessment with the iCONE robotic device and clinical scales. After T0 evaluation, the robot was delivered to the patient's home for 10 days of at-home treatment (5 days a week for 2 weeks). Results: Comparison between T0 and T1 evaluations revealed some significant improvements in robot-evaluated indices such as Independence and Size for the Circle Drawing exercise and Movement Duration for Point-to-Point exercise, but also in the MAS of the elbow. From the analysis of the acceptability questionnaire, a general appreciation of the robot emerged: patients spontaneously asked for the addition of further sessions and to continue therapy. Discussion: Telerehabilitation of patients suffering from a chronic stroke is an area that is still little explored. From our experience, this is one of the first studies to carry out a telerehabilitation with these characteristics. The use of robots can become a method to reduce the rehabilitation health costs, to ensure continuity of care, and to arrive in more distant places or where the availability of resources is limited. Conclusion: From the data obtained, this rehabilitation seems to be promising for this population. Moreover, promoting the recovery of the upper limb, iCONE can improve patient's quality of life. It would be interesting to conduct RCT studies to compare a conventional treatment in structure with a robotic telematics treatment.

6.
Open Res Eur ; 1: 55, 2022 Apr 21.
Article in English | MEDLINE | ID: mdl-35747768

ABSTRACT

Background: The autonomic nervous system is the main determinant of the blood flow directed towards a body part, and it is tightly connected to the representation of the body in the brain; would the experimental modulation of the sense of limb ownership affect its blood perfusion? Methods: In healthy participants, we employed the rubber hand illusion paradigm to modulate limb ownership while we monitored the brachial artery blood flow and resistance index within the investigated limb. Results: In all conditions with brush-stroking, we found an initial drop in the blood flow due to tactile stimulation. Subsequently, in the illusion condition (where both the rubber and real hand synchronous brush-stroking were present), the blood flow rose significantly faster and reached significantly higher values. Moreover, the increase in blood flow correlated with the extent of embodiment as measured by questionnaires and correlated negatively with the change of peripherical vascular resistance. Conclusions: These findings suggest that modulating the representation of a body part impacts its blood perfusion.

7.
J Neurophysiol ; 126(2): 477-492, 2021 08 01.
Article in English | MEDLINE | ID: mdl-34232750

ABSTRACT

Sensory feedback is pivotal for a proficient dexterity of the hand. By modulating the grip force in function of the quick and not completely predictable change of the load force, grabbed objects are prevented to slip from the hand. Slippage control is an enabling achievement to all manipulation abilities. However, in hand prosthetics, the performance of even the most innovative research solutions proposed so far to control slippage remain distant from the human physiology. Indeed, slippage control involves parallel and compensatory activation of multiple mechanoceptors, spinal and supraspinal reflexes, and higher-order voluntary behavioral adjustments. In this work, we reviewed the literature on physiological correlates of slippage to propose a three-phases model for the slip sensation and reaction. Furthermore, we discuss the main strategies employed so far in the research studies that tried to restore slippage control in amputees. In the light of the proposed three-phase slippage model and from the weaknesses of already implemented solutions, we proposed several physiology-inspired solutions for slippage control to be implemented in the future hand prostheses. Understanding the physiological basis of slip detection and perception and implementing them in novel hand feedback system would make prosthesis manipulation more efficient and would boost its perceived naturalness, fostering the sense of agency for the hand movements.


Subject(s)
Artificial Limbs , Hand Strength , Psychomotor Performance , Brain/physiology , Hand/physiology , Humans , Touch Perception
8.
Cereb Cortex ; 31(7): 3299-3310, 2021 06 10.
Article in English | MEDLINE | ID: mdl-33611384

ABSTRACT

Motor planning and execution require a representational map of our body. Since the body can assume different postures, it is not known how it is represented in this map. Moreover, is the generation of the motor command favored by some body configurations? We investigated the existence of a centrally favored posture of the hand for action, in search of physiological and behavioral advantages due to central motor processing. We tested two opposite hand pinch grips, equally difficult and commonly used: forearm pronated, thumb-down, index-up pinch against the same grip performed with thumb-up. The former revealed faster movement onset, sign of faster neural computation, and faster target reaching. It induced increased corticospinal excitability, independently on pre-stimulus tonic muscle contraction. Remarkably, motor excitability also increased when thumb-down pinch was only observed, imagined, or prepared, actually keeping the hand at rest. Motor advantages were independent of any concurrent modulation due to somatosensory input, as shown by testing afferent inhibition. Results provide strong behavioral and physiological evidence for a preferred hand posture favoring brain motor control, independently by somatosensory processing. This suggests the existence of a baseline postural representation that may serve as an a priori spatial reference for body-space interaction.


Subject(s)
Evoked Potentials, Motor/physiology , Hand Strength/physiology , Hand/physiology , Imagination/physiology , Motor Cortex/physiology , Posture/physiology , Adult , Electromyography/methods , Female , Humans , Male , Middle Aged , Photic Stimulation/methods , Young Adult
9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 3248-3251, 2020 07.
Article in English | MEDLINE | ID: mdl-33018697

ABSTRACT

The Rubber Hand Illusion can be used to induce the illusion that a fake hand is part of one's own body. Thus, it can be used to alter the body representation. It was also reported that the Rubber Hand Illusion induces a proprioceptive drift of one's real hand toward the fake hand. The Rubber Hand Illusion can be induced when the fake hand is placed farther in the sagittal plane (distally) compared to the real hand. In this case, the induced update of the body representation is an elongation of the arm. Virtual Reality and haptic technologies can be used to manipulate the perceived scenario in a virtual version of the Rubber Hand Illusion, the Virtual Hand Illusion. We developed a novel platform consisting in a virtual reality application integrating an optical motion capture device and haptic stimulators to study the manipulation of the body representation. We developed two experimental protocols to induce embodiment of an elongated arm: one validated in previous studies, that employs congruent visuo-motor-tactile stimulation, and one reproducing the typical Virtual Hand Illusion where only congruent visuo-tactile stimulation was employed. We tested both protocols with healthy participants.


Subject(s)
Illusions , Touch Perception , Body Image , Hand , Humans , Proprioception
10.
Front Neurosci ; 14: 389, 2020.
Article in English | MEDLINE | ID: mdl-32477046

ABSTRACT

Embodiment is the percept that something not originally belonging to the self becomes part of the body. Feeling embodiment for a prosthesis may counteract amputees' altered image of the body and increase prosthesis acceptability. Prosthesis embodiment has been studied longitudinally in an amputee receiving feedback through intraneural and perineural multichannel electrodes implanted in her stump. Three factors-invasive (vs non-invasive) stimulation, training, and anthropomorphism-have been tested through two multisensory integration tasks: visuo-tactile integration (VTI) and crossing-hand effect in temporal order judgment (TOJ), the former more sensible to an extension of a safe margin around the body and the latter to action-oriented remapping. Results from the amputee participant were compared with the ones from healthy controls. Testing the participant with intraneural stimulation produced an extension of peripersonal space, a sign of prosthesis embodiment. One-month training extended the peripersonal space selectively on the side wearing the prostheses. More and less-anthropomorphic prostheses benefited of intraneural feedback and extended the peripersonal space. However, the worsening of TOJ performance following arm crossing was present only wearing the more trained, despite less anthropomorphic, prosthesis, suggesting that training was critical for our participant to achieve operative tool-like embodiment.

11.
J Cogn Neurosci ; 32(6): 1104-1116, 2020 06.
Article in English | MEDLINE | ID: mdl-31951156

ABSTRACT

The afferent branch of the autonomic nervous system contributes with interoception to the multimodal sensory correlation continuously needed to update our representation of the body. To test whether the modulation of body representation would have an impact on the efferent branch of the autonomic nervous system, nonspecific skin conductance has been measured in three rubber hand illusion (RHI) experiments, controlled with asynchronous brush-stroking and incongruent fake hand position. Nonspecific skin conductance standard deviation (SCSD) computed along the whole 90 sec of stroking was found to be increased by the illusion and to correlate with all the typical measures of embodiment. Computing SCSD in shorter time windows strongly enhanced the difference between illusion and controls. The highest difference was found in the 10-55 sec window, being the 14-34 sec window as the most informative one. The higher correlations with the validated measures of embodiment (all but the proprioceptive drift) were found for time windows ranging between 35 and 65 sec. The SCSD was no longer significantly higher when the RHI was repeated twice (two trials each iteration), but it was still significantly higher in synchronous stroking even when considering only the second trial. However, after the first iteration of the RHI paradigm, the effect of the embodiment on nonspecific skin conductance response results to be attenuated, suggesting that novelty in presentation of the RHI can contribute to the effect on nonspecific skin conductance response. Results candidate SCSD as a noninvasive, cheap, easy, and objective measure of embodiment, especially sensible to onset and strength of the illusion. Alike the already known enhanced autonomic reaction to a threatening, SCSD does not interfere with the collection of other behavioral measures. Correlations and their dynamics, presence of the effect in the second presentation of the setup but relative low robustness against multiple repetition, suggest that the increased fluctuations of skin conductance caught by SCSD are not just the effect of different presented sensory stimuli but more likely a stronger arousal response to the novelty of the updated perceptual status.


Subject(s)
Autonomic Nervous System/physiology , Body Image , Efferent Pathways/physiology , Galvanic Skin Response/physiology , Interoception/physiology , Touch Perception/physiology , Adult , Female , Hand/physiology , Humans , Illusions/physiology , Male , Visual Perception/physiology , Young Adult
12.
Cortex ; 121: 322-331, 2019 12.
Article in English | MEDLINE | ID: mdl-31670027

ABSTRACT

The ventral premotor cortex (PMv) is a key area of the sensorimotor control loop, it subtends complex motor sequences, especially when the hand is involved. However, its specific contribution to simple motor response to sensory cue is still not completely clear. To investigate the role of PMv, we used transcranial magnetic stimulation (TMS) to interfere with its function during a simple reaction time (SRT) task. We ran two experiments where participants were required to respond as fast as possible to a median nerve stimulation (go-signal), while sub-M1-threshold single pulse TMS was delivered either on left (contralateral) PMv or right (ipsilateral to sensory stimulus and motor response) PMv, 5-65 ms after the go-signal. TMS delivered on either PMv up to 25 ms after the go-signal shortened reaction time. This is the time window compatible with the arrive of sensory afferences, as if conditioning before sensory afferences arrive lower the threshold needed to release the pre-planned motor program to the primary motor cortex. This is in line with a putative PMv function of buffer of pre-planned motor program not strictly lateralized in one hemisphere.


Subject(s)
Evoked Potentials, Motor/physiology , Motor Cortex/physiology , Movement/physiology , Psychomotor Performance/physiology , Reaction Time/physiology , Adult , Female , Humans , Male , Neural Pathways/physiology , Transcranial Magnetic Stimulation/methods , Young Adult
13.
Front Neurosci ; 12: 870, 2018.
Article in English | MEDLINE | ID: mdl-30532689

ABSTRACT

An enhanced sense of prosthesis ownership may be the key for higher amputees' quality of life. In this study in 28 healthy subjects, neuronavigated intermittent Theta Burst Stimulation (iTBS) delivered over the right ventral premotor cortex or inferior parietal lobule has been tested, compared to sham stimulation, to enhance embodiment in the rubber hand illusion paradigm. Neuromodulation of both areas did not result in an enhancement of embodiment, as assessed by the results collected from a self-evaluation questionnaire for the extent of self-attribution of the rubber hand and proprioceptive drift. In all cases, the difference between synchronous and asynchronous stroking confirms the successful induction of the illusion. It may be speculated that the low consistency of iTBS over brain regions other than primary motor cortex may account for the absence of effect, suggesting to test other neuromodulating techniques, acting on cortical networks different from the ones sensitive to iTBS to enhance artificial hand embodiment.

14.
IEEE Int Conf Rehabil Robot ; 2017: 1136-1141, 2017 07.
Article in English | MEDLINE | ID: mdl-28813974

ABSTRACT

Partial hand amputation is the most frequent amputation level worldwide, accounting for approximately 90% of all upper limb amputations. Passive cosmetic prostheses represent one of the possible choices for its treatment, probably the most affordable one. However, these devices restore very limited motor function and subtle sensory feedback. The latter is an important component for restoring the body schema. In this work we present a simple yet potentially effective and low cost cosmetic digital prosthesis that embeds touch feedback; we dubbed this DESC-finger. It delivers short-lasting vibrotactile bursts when it makes and breaks contact with the environment, based on the Discrete Event-driven Sensory feedback Control (DESC) policy. One prototype was developed and used by one amputee at home, for two months. The effectiveness of the device was experimentally assessed by means of an interview and a virtual eggs test, which showed, albeit preliminarily, that time discrete feedback can improve the motor control of a partial hand prosthesis in daily life conditions. Besides targeting people that already use cosmetic digits, the DESC-finger targets those that do not use them complaining for loss of sensibility. The production costs and manufacturing process makes the DESC-finger suitable for exploitation in high- and low-income countries.


Subject(s)
Artificial Limbs , Feedback, Sensory/physiology , Fingers/physiology , Prosthesis Design/methods , Touch/physiology , Adult , Female , Humans
15.
IEEE Trans Neural Syst Rehabil Eng ; 24(12): 1314-1322, 2016 12.
Article in English | MEDLINE | ID: mdl-26584497

ABSTRACT

Human grasping and manipulation control critically depends on tactile feedback. Without this feedback, the ability for fine control of a prosthesis is limited in upper limb amputees. Although various approaches have been investigated in the past, at present there is no commercially available device able to restore tactile feedback in upper limb amputees. Based on the Discrete Event-driven Sensory feedback Control (DESC) policy we present a device able to deliver short-lasting vibrotactile feedback to transradial amputees using commercially available myoelectric hands. The device (DESC-glove) comprises sensorized thimbles to be placed on the prosthesis digits, a battery-powered electronic board, and vibrating units embedded in an arm-cuff being transiently activated when the prosthesis makes and breaks contact with objects. The consequences of using the DESC-glove were evaluated in a longitudinal study. Five transradial amputees were equipped with the device for one month at home. Through a simple test proposed here for the first time-the virtual eggs test-we demonstrate the effectiveness of the device for prosthetic control in daily life conditions. In the future the device could be easily exploited as an add-on to complement myoelectric prostheses or even embedded in prosthetic sockets to enhance their control by upper limb amputees.


Subject(s)
Amputees/rehabilitation , Artificial Limbs , Electromyography/methods , Feedback, Sensory , Robotics/instrumentation , Touch , Equipment Failure Analysis , Gloves, Protective , Hand/physiopathology , Hand Strength , Humans , Prosthesis Design , Radius/surgery , Task Performance and Analysis , Vibration , Wrist Joint/physiopathology
16.
J Neuroeng Rehabil ; 12: 77, 2015 Sep 04.
Article in English | MEDLINE | ID: mdl-26341285

ABSTRACT

BACKGROUND: Lower-limb amputation causes the individual a huge functional impairment due to the lack of adequate sensory perception from the missing limb. The development of an augmenting sensory feedback device able to restore some of the missing information from the amputated limb may improve embodiment, control and acceptability of the prosthesis. FINDINGS: In this work we transferred the Rubber Hand Illusion paradigm to the lower limb. We investigated the possibility of promoting body ownership of a fake foot, in a series of experiments fashioned after the RHI using matched or mismatched (vibrotactile) stimulation. The results, collected from 19 healthy subjects, demonstrated that it is possible to elicit the perception of possessing a rubber foot when modality-matched stimulations are provided synchronously on the biological foot and to the corresponding rubber foot areas. Results also proved that it is possible to enhance the illusion even with modality-mismatched stimulation, even though illusion was lower than in case of modality-matched stimulation. CONCLUSIONS: We demonstrated the possibility of promoting a Rubber Foot Illusion with both matched and mismatched stimulation.


Subject(s)
Amputation, Surgical/psychology , Foot , Illusions/psychology , Adult , Amputees/psychology , Artificial Limbs , Biofeedback, Psychology , Body Image , Female , Healthy Volunteers , Humans , Illusions/etiology , Lower Extremity/injuries , Lower Extremity/surgery , Male , Physical Stimulation , Self Concept
17.
IEEE Trans Neural Syst Rehabil Eng ; 23(3): 450-7, 2015 May.
Article in English | MEDLINE | ID: mdl-25051556

ABSTRACT

Tactile feedback is essential to intuitive control and to promote the sense of self-attribution of a prosthetic limb. Recent findings showed that amputees can be tricked to experience this embodiment, when synchronous and modality-matched stimuli are delivered to biological afferent structures and to an alien rubber hand. Hence, it was suggested to exploit this effect by coupling touch sensors in a prosthesis to an array of haptic tactile stimulators in the prosthetic socket. However, this approach is not clinically viable due to physical limits of current haptic devices. To address this issue we have proposed modality-mismatched stimulation and demonstrated that this promotes self-attribution of an alien hand on normally limbed subjects. In this work we investigated whether similar effects could be induced in transradial amputees with referred phantom sensations in a series of experiments fashioned after the Rubber Hand Illusion using vibrotactile stimulators. Results from three independent measures of embodiment demonstrated that vibrotactile sensory substitution elicits body-ownership of a rubber hand in transradial amputees. These results open up promising possibilities in this field; indeed miniature, safe and inexpensive vibrators could be fitted into commercially available prostheses and sockets to induce the illusion every time the prosthesis manipulates an object.


Subject(s)
Alien Limb Phenomenon/psychology , Amputees/psychology , Phantom Limb/psychology , Touch/physiology , Vibration , Adult , Aged , Female , Galvanic Skin Response/physiology , Hand/innervation , Humans , Illusions/psychology , Male , Middle Aged , Physical Stimulation , Proprioception/physiology , Prosthesis Design , Surveys and Questionnaires , Young Adult
18.
IEEE Trans Haptics ; 7(2): 181-90, 2014.
Article in English | MEDLINE | ID: mdl-24968382

ABSTRACT

An important reason for the abandonment of commercial actuated hand prostheses by the users is the lack of sensory feedback. Wearable afferent interfaces capable of providing electro- or vibro-tactile stimulation have high potential to restore the missing tactile and/or proprioceptive information to the user. By definition, these devices can elicit single modality (i.e., either vibrotactile or electrotactile) substitute sensations. In a recent research we have presented a novel approach comprising hybrid vibro-electrotactile (HyVE) combined stimulation, in order to provide multimodal sensory feedback. An important advantage of this approach is in the size of the design: the HyVE interface is much more compact than two separated single-modality interfaces, since electro- and vibro-tactile stimulators are placed one on top of the other. The HyVE approach has been previously tested in healthy subjects and has shown to provide a range of hybrid stimuli that could be properly discriminated. However, this approach has never been assessed as a method to provide multi-channel stimuli, i.e., stimuli from a variety of stimulators, mapping information from a multitude of sensors on a prosthesis. In this study, the ability of ten healthy subjects to discriminate stimuli and patterns of stimuli from four different five-channel interfaces applied on their forearms was evaluated. We showed that multiple HyVE units could be used to provide multi-channel sensory information with equivalent performance (∼95 percent for single stimuli and ∼80 percent for pattern) to single modality interfaces (vibro- or electro-tactile) larger in size and with better performance than vibrotactile interfaces (i.e., 73 percent for single stimuli and 69 percent for pattern) with the same size. These results are promising in relation to the current availability of multi-functional prostheses with multiple sensors.


Subject(s)
Feedback, Sensory/physiology , Physical Stimulation/instrumentation , Touch Perception/physiology , User-Computer Interface , Vibration , Adult , Artificial Limbs/standards , Discrimination, Psychological/physiology , Electric Stimulation/instrumentation , Humans
19.
IEEE Trans Neural Syst Rehabil Eng ; 22(2): 290-301, 2014 Mar.
Article in English | MEDLINE | ID: mdl-23782817

ABSTRACT

Electro- or vibro-tactile stimulations were used in the past to provide sensory information in many different applications ranging from human manual control to prosthetics. The two modalities were used separately in the past, and we hypothesized that a hybrid vibro-electrotactile (HyVE) stimulation could provide two afferent streams that are independently perceived by a subject, although delivered in parallel and through the same skin location. We conducted psychophysical experiments where healthy subjects were asked to recognize the intensities of electroand vibro-tactile stimuli during hybrid and single modality stimulations. The results demonstrated that the subjects were able to discriminate the features of the two modalities within the hybrid stimulus, and that the cross-modality interaction was limited enough to allow better transmission of discrete information (messages) using hybrid versus singlemodality coding. The percentages of successful recognitions (mean ± standard deviation) for nine messages were 56 ± 11 % and 72 ± 8 % for two hybrid coding schemes, compared to 29 ±7 % for vibrotactile and 44 ± 4 % for electrotactile coding. The HyVE can be therefore an attractivesolution in numerous application for providing sensory feedbackin prostheses and rehabilitation, and it could be used to increase the resolution of a single variable or to simultaneously feedback two different variables.


Subject(s)
Electric Stimulation/instrumentation , Feedback, Sensory/physiology , Physical Stimulation/instrumentation , Rehabilitation/methods , Touch/physiology , Adult , Data Interpretation, Statistical , Discrimination, Psychological/physiology , Electric Stimulation/methods , Electrodes , Female , Humans , Male , Physical Stimulation/methods , Prostheses and Implants , Psychomotor Performance/physiology , Sensation/physiology , Skin/innervation , Vibration
20.
Expert Rev Med Devices ; 10(1): 45-54, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23278223

ABSTRACT

One of the challenges facing prosthetic designers and engineers is to restore the missing sensory function inherit to hand amputation. Several different techniques can be employed to provide amputees with sensory feedback: sensory substitution methods where the recorded stimulus is not only transferred to the amputee, but also translated to a different modality (modality-matched feedback), which transfers the stimulus without translation and direct neural stimulation, which interacts directly with peripheral afferent nerves. This paper presents an overview of the principal works and devices employed to provide upper limb amputees with sensory feedback. The focus is on sensory substitution and modality matched feedback; the principal features, advantages and disadvantages of the different methods are presented.


Subject(s)
Amputation Stumps/physiopathology , Amputees/rehabilitation , Artificial Limbs , Biofeedback, Psychology/instrumentation , Feedback, Sensory , Upper Extremity/physiopathology , Equipment Failure Analysis , Humans , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...