Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
Add more filters










Publication year range
2.
Minerva Anestesiol ; 88(9): 680-689, 2022 09.
Article in English | MEDLINE | ID: mdl-35315620

ABSTRACT

BACKGROUND: Viscoelastic tests (VETs) are recommended during cardiac surgery to monitor coagulation status and guide transfusion. We compared the results of two VETs, the Sonoclot Analyzer and the ROTEM Sigma. Agreement between viscoelastic tests' subdiagnoses and overall diagnosis severity was assessed. Correlations with conventional coagulation tests (CCT) and the discriminatory potential of numerical VET outputs for transfusion thresholds was determined. METHODS: Single-center, prospective observational study in a tertiary academic center. In fifty adult patients undergoing elective cardiac surgery, parallel Sonoclot, ROTEM and CCT analysis was performed before heparin, or after protamine or coagulation product administration. All patients completed the study, resulting in 139 data points. RESULTS: Agreement on the severity of coagulation disorders was acceptable (83%), but poor (27%) on the differentiation of the underlying causes. Correlations between ROTEM parameters and CCT were good (postprotamine: FIBTEM A5 (r2=0.90 vs. fibrinogen) and EXTEM-FIBTEM A5 difference (r2=0.81 vs. platelet count). Sonoclot correlated less (Clot Rate (r2=0.25 vs. fibrinogen) and Platelet Function (r2=0.43 vs. platelet count). This was reflected in the discriminatory potential of these parameters as found by linear mixed modelling. We suggest clinically useful grey zones for VET cutoff interpretation. CONCLUSIONS: ROTEM and Sonoclot accord well on the detection of severity of coagulation dysfunction, but not on the diagnosis of the underlying cause. ROTEM correlated more closely with CCT then Sonoclot. We propose a testing strategy that could lead to a cost-effective approach to the bleeding cardiac surgery patient.


Subject(s)
Cardiac Surgical Procedures , Thrombelastography , Adult , Blood Coagulation , Blood Coagulation Tests , Cardiac Surgical Procedures/methods , Fibrinogen , Humans , Thrombelastography/methods
4.
J Thromb Haemost ; 19(6): 1460-1471, 2021 06.
Article in English | MEDLINE | ID: mdl-33724649

ABSTRACT

BACKGROUND: Mild to moderate bleeding disorders are a diagnostic challenge. Many patients remain undiagnosed despite thorough and repeated laboratory testing. Thrombin generation (TG) is an overall assay measuring the functionality of the hemostatic system and may be a useful tool in diagnosing patients with bleeding tendency. OBJECTIVES: We examined the added value of TG in patients with mild bleeding tendency with and without diagnosis after classical laboratory testing. Further, we investigated the role of different expressions of results, between-method variation, and reference ranges. METHODS: TG of patients and controls was measured in parallel by two TG platforms (ST Genesia and calibrated automated thrombogram [CAT]). All TG parameters in patient and control groups were compared by statistical analysis (Mann-Whitney U tests) including visual representation with box-and-whisker plots. Results were expressed as normalized ratios (ST Genesia and CAT) or corrected values (ST Genesia). Reference intervals were calculated to which patient results were compared. We studied lot-to-lot reagent variability for both platforms. RESULTS: In 62.7% (ST Genesia) to 69.5% (CAT) of patients undiagnosed with a traditional laboratory work-up, abnormal TG parameters (lag time and endogenous thrombin potential expressed as normalized ratio and/or corrected value) were detected. In the group of previously diagnosed patients, abnormal parameters were found in 58.1% of patients for both TG assays. No relevant lot-to-lot reagent variability was observed. CONCLUSIONS: Adding TG helps with diagnosing patients with mild bleeding disorder. TG seems a promising tool in diagnosis of bleeding tendency, but further evaluation is necessary before application in diagnostic laboratory testing.


Subject(s)
Blood Coagulation Disorders , Thrombin , Blood Coagulation Tests , Hemostasis , Humans , Reference Values
5.
J Thromb Haemost ; 18(8): 2003-2017, 2020 08.
Article in English | MEDLINE | ID: mdl-32400112

ABSTRACT

BACKGROUND: Direct oral anticoagulants (DOACs) interfere with lupus anticoagulant (LAC) testing. DOAC-Stop (D-S) represents a preanalytical strategy to cope with this issue. OBJECTIVES: To assess D-S's ability to remove DOACs from plasma and overcome DOAC interference in LAC assays and to evaluate D-S's applicability in a representative patient cohort with routine LAC request. METHODS: Apixaban (30-933 ng/mL), edoxaban (31-1060 ng/mL), rivaroxaban (35-1020 ng/mL), and dabigatran (20-360 ng/mL) were spiked to normal plasma. Aliquots were treated with D-S or untreated before DOAC and LAC testing. Patient samples containing DOAC (n = 43), vitamin K antagonists (n = 25), heparins (n = 21), or no anticoagulants (n = 63) were tested for LAC before and after D-S. RESULTS: Spiking experiments revealed false-positive LAC from low concentrations of DOACs except for apixaban. Following D-S, DOAC levels were below lower limits of quantification, except for apixaban at the highest concentration, and no false-positive LAC was obtained. DOAC levels were below lower limits of quantification after D-S in 39/43 DOAC-containing patient samples. For 23/29 LAC-positive DOAC-containing samples, LAC tests became negative after D-S, whereas 3/6 samples remaining positive were from patients with (high probability for) antiphospholipid syndrome. In the non-DOAC-treated groups, LAC changed from positive to negative in 10 and vice versa in 2 cases. CONCLUSIONS: D-S limits DOAC interference in LAC assays. DOAC concentration measurement should be performed in D-S treated samples because incomplete removal may occur. Applying D-S to vitamin K antagonist-containing, heparin-containing, or not-anticoagulated samples may lead to erroneous LAC results. Therefore, D-S should only be used in plasma from DOAC-treated patients.


Subject(s)
Antiphospholipid Syndrome , Lupus Coagulation Inhibitor , Administration, Oral , Adsorption , Anticoagulants/therapeutic use , Antiphospholipid Syndrome/drug therapy , Dabigatran , Humans , Pyridones , Rivaroxaban
6.
Res Pract Thromb Haemost ; 4(1): 161-168, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31989098

ABSTRACT

BACKGROUND: Heparins and heparinoids interfere with functional clotting assays used for lupus anticoagulant (LAC) detection. However, current guidelines for LAC testing do not provide clear guidance on this matter. OBJECTIVES: We aimed to assess to effect of unfractionated heparin (UFH), enoxaparin, and danaparoid on LAC assays over broad anti-Xa activity ranges and to evaluate whether activated carbon (AC) is able to neutralize these effects. METHODS: UFH (0.1-3.0 IU/mL), enoxaparin (0.2-2.9 IU/mL), and danaparoid (0.6-2.2 IU/mL) were spiked to normal pooled plasma. AC was added at multiple activity levels. Anti-Xa assays and LAC tests were performed on all samples using Stago analyzers and reagents. RESULTS: Abnormal activated partial thromboplastin time (APTT) screening and mixing tests were obtained at the lowest levels for all compounds. Abnormal APTT confirmation tests were seen from 2.5 and 1.9 anti-Xa IU/mL for enoxaparin and danaparoid, respectively. Abnormal dilute Russell's viper venom test (dRVVT) screening tests were obtained from 1.6, 1.4, and 1.1 anti-Xa IU/mL for UFH, enoxaparin, and danaparoid, respectively. Mixing tests were abnormal from 2.5 and 1.3 anti-Xa IU/mL for enoxaparin and danaparoid, respectively. Abnormal dRVVT confirmation results were seen for danaparoid only from 1.9 anti-Xa IU/mL. AC was unable to neutralize anti-Xa activity in plasma and overcome the effect of the tested anticoagulants on LAC assays but may cause prolongation of APTT clotting times. CONCLUSIONS: UFH, enoxaparin, and danaparoid clearly affected LA tests; however, false-positive LAC conclusions were obtained at supratherapeutic enoxaparin and danaparoid levels only. AC may prolong APTT screen clotting times, requiring 3-step testing to avoid potential misdiagnosis of LAC.

8.
Anal Chem ; 90(3): 1795-1804, 2018 02 06.
Article in English | MEDLINE | ID: mdl-29281263

ABSTRACT

The hematocrit (Hct) effect is one of the most important hurdles currently preventing more widespread implementation of quantitative dried blood spot (DBS) analysis in a routine context. Indeed, the Hct may affect both the accuracy of DBS methods as well as the interpretation of DBS-based results. We previously developed a method to determine the Hct of a DBS based on its hemoglobin content using noncontact diffuse reflectance spectroscopy. Despite the ease with which the analysis can be performed (i.e., mere scanning of the DBS) and the good results that were obtained, the method did require a complicated algorithm to derive the total hemoglobin content from the DBS's reflectance spectrum. As the total hemoglobin was calculated as the sum of oxyhemoglobin, methemoglobin, and hemichrome, the three main hemoglobin derivatives formed in DBS upon aging, the reflectance spectrum needed to be unmixed to determine the quantity of each of these derivatives. We now simplified the method by only using the reflectance at a single wavelength, located at a quasi-isosbestic point in the reflectance curve. At this wavelength, assuming 1-to-1 stoichiometry of the aging reaction, the reflectance is insensitive to the hemoglobin degradation and only scales with the total amount of hemoglobin and, hence, the Hct. This simplified method was successfully validated. At each quality control level as well as at the limits of quantitation (i.e., 0.20 and 0.67) bias, intra- and interday imprecision were within 10%. Method reproducibility was excellent based on incurred sample reanalysis and surpassed the reproducibility of the original method. Furthermore, the influence of the volume spotted, the measurement location within the spot, as well as storage time and temperature were evaluated, showing no relevant impact of these parameters. Application to 233 patient samples revealed a good correlation between the Hct determined on whole blood and the predicted Hct determined on venous DBS. The bias obtained with Bland and Altman analysis was -0.015 and the limits of agreement were -0.061 and 0.031, indicating that the simplified, noncontact Hct prediction method even outperforms the original method. In addition, using caffeine as a model compound, it was demonstrated that this simplified Hct prediction method can effectively be used to implement a Hct-dependent correction factor to DBS-based results to alleviate the Hct bias.


Subject(s)
Dried Blood Spot Testing/methods , Hematocrit , Spectrophotometry/methods , Adult , Algorithms , Humans , Linear Models , Reproducibility of Results
9.
Clin Pharmacokinet ; 55(2): 169-84, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26239501

ABSTRACT

Interindividual variability in the expression and function of drug metabolizing cytochrome P (CYP) 450 enzymes, determined by a combination of genetic, non-genetic and environmental parameters, is a major source of variable drug response. Phenotyping by administration of a selective enzyme substrate, followed by the determination of a specific phenotyping metric, is an appropriate approach to assess the in vivo activity of CYP450 enzymes as it takes into account all influencing factors. A phenotyping protocol should be as simple and convenient as possible. Typically, phenotyping metrics are determined in traditional matrices, such as blood, plasma or urine. Several sampling strategies have been proposed as an alternative for these traditional sampling techniques. In this review, we provide a comprehensive overview of available methods using dried blood spots (DBS), hair, oral fluid, exhaled breath and sweat for in vivo CYP450 phenotyping. We discuss the relation between phenotyping metrics measured in these samples and those in conventional matrices, along with the advantages and limitations of the alternative sampling techniques. Reliable phenotyping procedures for several clinically relevant CYP450 enzymes, including CYP1A2, CYP2C19 and CYP2D6, are currently available for oral fluid, breath or DBS, while additional studies are needed for other CYP450 isoforms, such as CYP3A4. The role of hair analysis for this purpose remains to be established. Being non- or minimally invasive, these sampling strategies provide convenient and patient-friendly alternatives for classical phenotyping procedures, which may contribute to the implementation of CYP450 phenotyping in clinical practice.


Subject(s)
Cytochrome P-450 Enzyme System/metabolism , Breath Tests , Cytochrome P-450 Enzyme System/blood , Hair/enzymology , Humans , Phenotype , Saliva/enzymology , Specimen Handling
10.
Talanta ; 144: 62-70, 2015 Nov 01.
Article in English | MEDLINE | ID: mdl-26452792

ABSTRACT

Caffeine is the probe drug of choice to assess the phenotype of the drug metabolizing enzyme CYP1A2. Typically, molar concentration ratios of paraxanthine, caffeine's major metabolite, to its precursor are determined in plasma following administration of a caffeine test dose. The aim of this study was to develop and validate an LC-MS/MS method for the determination of caffeine and paraxanthine in hair. The different steps of a hair extraction procedure were thoroughly optimized. Following a three-step decontamination procedure, caffeine and paraxanthine were extracted from 20 mg of ground hair using a solution of protease type VIII in Tris buffer (pH 7.5). Resulting hair extracts were cleaned up on Strata-X™ SPE cartridges. All samples were analyzed on a Waters Acquity UPLC® system coupled to an AB SCIEX API 4000™ triple quadrupole mass spectrometer. The final method was fully validated based on international guidelines. Linear calibration lines for caffeine and paraxanthine ranged from 20 to 500 pg/mg. Precision (%RSD) and accuracy (%bias) were below 12% and 7%, respectively. The isotopically labeled internal standards compensated for the ion suppression observed for both compounds. Relative matrix effects were below 15%RSD. The recovery of the sample preparation procedure was high (>85%) and reproducible. Caffeine and paraxanthine were stable in hair for at least 644 days. The effect of the hair decontamination procedure was evaluated as well. Finally, the applicability of the developed procedure was demonstrated by determining caffeine and paraxanthine concentrations in hair samples of ten healthy volunteers. The optimized and validated method for determination of caffeine and paraxanthine in hair proved to be reliable and may serve to evaluate the potential of hair analysis for CYP1A2 phenotyping.


Subject(s)
Caffeine/analysis , Caffeine/isolation & purification , Chromatography, Liquid/methods , Hair/chemistry , Solid Phase Extraction/methods , Tandem Mass Spectrometry/methods , Theophylline/analysis , Theophylline/isolation & purification , Adult , Analytic Sample Preparation Methods , Caffeine/metabolism , Female , Humans , Male , Theophylline/metabolism , Young Adult
11.
Anal Chim Acta ; 881: 65-73, 2015 Jun 30.
Article in English | MEDLINE | ID: mdl-26041521

ABSTRACT

Volumetric absorptive microsampling (VAMS) is a novel sampling technique that allows the straightforward collection of an accurate volume of blood (approximately 10µL) from a drop or pool of blood by dipping an absorbent polymeric tip into it. The resulting blood microsample is dried and analyzed as a whole. The aim of this study was to evaluate the potential of VAMS to overcome the hematocrit bias, an important issue in the analysis of dried blood microsamples. An LC-MS/MS method for analysis of the model compounds caffeine and paraxanthine in VAMS samples was fully validated and fulfilled all pre-established criteria. In conjunction with previously validated procedures for dried blood spots (DBS) and blood, this allowed us to set up a meticulous comparative study in which both compounds were determined in over 80 corresponding VAMS, DBS and liquid whole blood samples. These originated from authentic human patient samples, covering a wide hematocrit range (0.21-0.50). By calculating the differences with reference whole blood concentrations, we found that analyte concentrations in VAMS samples were not affected by a bias that changed over the evaluated hematocrit range, in contrast to DBS results. However, VAMS concentrations tend to overestimate whole blood concentrations, as a consistent positive bias was observed. A different behavior of VAMS samples prepared from incurred and spiked blood, combined with a somewhat reduced recovery of caffeine and paraxanthine from VAMS tips at high hematocrit values, an effect that was not observed for DBS using a very similar extraction procedure, was found to be at the basis of the observed VAMS-whole blood deviations. Based on this study, being the first in which the validity and robustness of VAMS is evaluated by analyzing incurred human samples, it can be concluded that VAMS effectively assists in eliminating the effect of hematocrit.


Subject(s)
Blood Specimen Collection/methods , Caffeine/blood , Dried Blood Spot Testing/methods , Theophylline/blood , Chromatography, Gas , Healthy Volunteers , Hematocrit , Humans , Reproducibility of Results , Sensitivity and Specificity , Tandem Mass Spectrometry
12.
Clin Pharmacokinet ; 54(7): 771-81, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25603821

ABSTRACT

BACKGROUND AND OBJECTIVE: Although metabolite-to-parent drug concentration ratios in hair have been suggested as a possible tool to study the metabolism of drugs in a non-invasive way, no studies are available that evaluated this in a systematic way. Cytochrome P450 (CYP) 1A2 is a drug-metabolizing enzyme characterized by large inter-individual differences in its activity. The standard approach for CYP1A2 phenotyping is to determine the paraxanthine/caffeine ratio in plasma at a fixed timepoint after intake of a dose of the CYP1A2 substrate caffeine. The aim of this study was to evaluate whether paraxanthine/caffeine ratios measured in hair samples reflect the plasma-based CYP1A2 phenotype. METHODS: Caffeine and paraxanthine concentrations were measured in proximal 3 cm segments of hair samples from 60 healthy volunteers and resulting paraxanthine/caffeine ratios were correlated with CYP1A2 phenotyping indices in plasma. RESULTS: Paraxanthine/caffeine ratios in hair ranged from 0.12 to 0.93 (median 0.41); corresponding ratios in plasma ranged from 0.09 to 0.95 (median 0.40). A statistically significant correlation was found between ratios in hair and plasma (r = 0.41, p = 0.0011). However, large deviations between ratios in both matrices were found in individual cases. Although the influence of several factors on paraxanthine/caffeine ratios and hair-plasma deviations was investigated, no evident factors explaining the observed variability could be identified. CONCLUSION: The variability between hair and plasma ratios complicates the interpretation of hair paraxanthine/caffeine ratios on an individual basis and, therefore, compromises their practical usefulness as alternative CYP1A2 phenotyping matrix.


Subject(s)
Caffeine/pharmacokinetics , Cytochrome P-450 CYP1A2/metabolism , Hair/metabolism , Theophylline/pharmacokinetics , Adult , Caffeine/analysis , Caffeine/blood , Cytochrome P-450 CYP1A2/blood , Female , Hair/chemistry , Humans , Male , Middle Aged , Phenotype , Theophylline/analysis , Theophylline/blood , Young Adult
13.
Bioanalysis ; 6(17): 2211-27, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25383733

ABSTRACT

Dried blood spot (DBS) sampling and DBS analysis have increasingly received attention during recent years. Furthermore, a substantial number of DBS methods has recently become available in clinical, forensic and occupational toxicology. In this review, we provide an overview of the different DBS-based methods that have been developed for detecting (markers of) abused substances. These include both legal and illegal drugs belonging to different categories, including cannabinoids, cocaine and metabolites, opioids, benzodiazepines and Z-drugs, amphetamines and analogs, gamma-hydroxybutyric acid, ketamine and novel psychoactive substances such as cathinones. Markers of ethanol consumption and tobacco use are also covered in this review. Since the majority of published methods has shown promising results overall, an interesting role for DBS analysis in diverse toxicological applications can be envisaged. For the distinct applications, we discuss the specific potential and benefits of DBS, the associated limitations and challenges, as well as recent developments and future perspectives.


Subject(s)
Dried Blood Spot Testing/methods , Substance Abuse Detection/methods , Animals , Drug Stability , Forensic Toxicology , Humans , Limit of Detection
14.
Anal Bioanal Chem ; 406(26): 6749-55, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25168119

ABSTRACT

Although dried blood spot (DBS) sampling is increasingly receiving interest as a potential alternative to traditional blood sampling, the impact of hematocrit (Hct) on DBS results is limiting its final breakthrough in routine bioanalysis. To predict the Hct of a given DBS, potassium (K(+)) proved to be a reliable marker. The aim of this study was to evaluate whether application of an algorithm, based upon predicted Hct or K(+) concentrations as such, allowed correction for the Hct bias. Using validated LC-MS/MS methods, caffeine, chosen as a model compound, was determined in whole blood and corresponding DBS samples with a broad Hct range (0.18-0.47). A reference subset (n = 50) was used to generate an algorithm based on K(+) concentrations in DBS. Application of the developed algorithm on an independent test set (n = 50) alleviated the assay bias, especially at lower Hct values. Before correction, differences between DBS and whole blood concentrations ranged from -29.1 to 21.1%. The mean difference, as obtained by Bland-Altman comparison, was -6.6% (95% confidence interval (CI), -9.7 to -3.4%). After application of the algorithm, differences between corrected and whole blood concentrations lay between -19.9 and 13.9% with a mean difference of -2.1% (95% CI, -4.5 to 0.3%). The same algorithm was applied to a separate compound, paraxanthine, which was determined in 103 samples (Hct range, 0.17-0.47), yielding similar results. In conclusion, a K(+)-based algorithm allows correction for the Hct bias in the quantitative analysis of caffeine and its metabolite paraxanthine.


Subject(s)
Algorithms , Caffeine/blood , Dried Blood Spot Testing/methods , Hematocrit , Potassium/blood , Theophylline/blood , Humans , Limit of Detection
16.
Bioanalysis ; 6(22): 3011-24, 2014.
Article in English | MEDLINE | ID: mdl-25096793

ABSTRACT

BACKGROUND: Phenotyping, using caffeine as probe substrate, is a proper method to assess CYP1A2 activity. We evaluated the utility of dried blood spots (DBS) for CYP1A2 phenotyping. RESULTS: LC-MS/MS methods were developed and validated for quantitation of caffeine and its metabolite paraxanthine in DBS, whole blood and plasma. All parameters met the pre-established criteria. While recovery, matrix effects and precision were unaffected by hematocrit (Hct), there was a Hct effect on accuracy, although for the evaluated Hct interval (0.36-0.50) it remained within acceptable limits. The phenotyping methods were successfully applied in healthy volunteers. CONCLUSION: Excellent method performance and highly comparable phenotyping indices in DBS, whole blood and plasma, combined with the benefits of DBS sampling, illustrate the suitability of DBS-based CYP1A2 phenotyping.


Subject(s)
Cytochrome P-450 CYP1A2/blood , Caffeine/blood , Chromatography, Liquid , Humans , Plasma/enzymology , Reproducibility of Results , Tandem Mass Spectrometry , Theophylline/blood
17.
Clin Pharmacokinet ; 53(8): 763-71, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24980692

ABSTRACT

BACKGROUND AND OBJECTIVE: Dried blood spot (DBS) sampling has gained wide interest in bioanalysis during the last decade and has already been successfully applied in pharmacokinetic and phenotyping studies. However, all of the available phenotyping studies used small datasets and did not include a systematic evaluation of DBS-specific parameters. The latter is important since several of these factors still challenge the breakthrough of DBS in routine practice. In this study, caffeine and paraxanthine are determined in capillary DBS, venous DBS, whole blood and plasma for cytochrome P450 (CYP) 1A2 phenotyping. The aim of this study was to explore the usefulness of DBS as a tool for CYP1A2 phenotyping. METHODS: A CYP1A2 phenotyping study was conducted in 73 healthy volunteers who received a 150 mg oral dose of caffeine. Six hours post-administration, caffeine and paraxanthine concentrations and paraxanthine:caffeine molar concentration ratios, i.e., the actual CYP1A2 phenotyping indices, were determined in capillary DBS (obtained by non-volumetric application, direct from the fingertip), venous DBS, whole blood, and plasma. Furthermore, the impact of DBS-specific parameters, including hematocrit, volume spotted, and punch location, was evaluated. RESULTS: Concentrations of caffeine and paraxanthine in capillary DBS were, respectively, on average 12.7 and 13.8% lower than those in venous DBS and 31.5 and 33.1% lower than those in plasma. While these differences were statistically significant (p < 0.001), no significant difference was observed between the paraxanthine:caffeine molar ratios in the distinct evaluated matrices (p ≥ 0.053). This ratio also alleviated the impact of hematocrit and volume spotted. CONCLUSIONS: Using the largest DBS-based phenotyping study to date, we have demonstrated that CYP1A2 phenotyping in capillary DBS is a valid and convenient alternative for the classical plasma-based approach. Additionally, we have provided an objective basis as to why DBS are an ideal tool for CYP1A2 phenotyping.


Subject(s)
Caffeine/blood , Cytochrome P-450 CYP1A2/blood , Dried Blood Spot Testing/methods , Adult , Caffeine/administration & dosage , Caffeine/metabolism , Cytochrome P-450 CYP1A2/metabolism , Female , Healthy Volunteers , Humans , Male , Middle Aged , Phenotype , Regression Analysis , Theophylline/blood , Young Adult
18.
Crit Rev Toxicol ; 42(3): 230-43, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22348353

ABSTRACT

About a century after its first described application by Ivar Bang, the potential of sampling via dried blood spots (DBS) as an alternative for classical venous blood sampling is increasingly recognized. Perhaps best known is the use of DBS in newborn screening programs, ignited by the hallmark paper by Guthrie and Susi half a century ago. However, it is only recently that both academia and industry have recognized the many advantages that DBS sampling may offer for bioanalytical purposes, as reflected by the strong increase in published reports during the last few years. Currently, major DBS applications include newborn screening for metabolic disorders, epidemiological surveys (e.g. HIV monitoring), therapeutic drug monitoring (TDM), as well as toxicology. In this review, we provide a comprehensive overview of the distinct subdisciplines of toxicology for which DBS sampling has been applied. DBS sampling for toxicological evaluation has been performed from birth until autopsy, aiming at the assessment of therapeutic drugs, drugs of abuse, environmental contaminants, toxins, as well as (trace) elements, with applications situated in fields as toxicokinetics, epidemiology and environmental and forensic toxicology. We discuss the strengths and limitations of DBS in the different subdisciplines and provide future prospects for the use of this promising sampling technique in toxicology.


Subject(s)
Dried Blood Spot Testing/methods , Forensic Toxicology/methods , Animals , Blood Specimen Collection/methods , Drug Monitoring/methods , Environmental Monitoring , Humans , Infant, Newborn , Neonatal Screening
SELECTION OF CITATIONS
SEARCH DETAIL
...