Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Prev Med Hyg ; 61(2): E296-E298, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32803014

ABSTRACT

INTRODUCTION: The microbiological safety and control of the water used in dental practice has a critical importance for avoiding cross-linked infections in the dental office. The aim of this study was to establish coxsackie virus filtration of the water applied to a dental unit. METHODS: A specific water filter-system was used, to verify the viral load in the outgoing water. The statistical analysis was performedusing the Shapiro-Wilk and t-Student test. RESULTS: The outcome of the evaluation of the virologic tests shows an excellent capability of virus filtration that attested 99.9999% in the volume analyzed. A statistical difference was found in the bacterial water contamination parameter before and after filtration. (P = 0.000000). CONCLUSIONS: According to the tests, medical devices applied to a dental unit are able to filter viruses and therefore reduce risk of contamination in the dental office.


Subject(s)
Coxsackievirus Infections/prevention & control , Cross Infection/prevention & control , Dentistry , Equipment Contamination/prevention & control , Filtration/instrumentation , Filtration/standards , Humans , Viral Load , Water Microbiology , Water Supply
2.
Clin Ter ; 168(4): e229-e232, 2017.
Article in English | MEDLINE | ID: mdl-28703836

ABSTRACT

AIMS: The aim of this study is to present a clinical case of a full arch prosthetic rehabilitation on natural teeth, combining both digital work-flow and monolithic zirconia. PATIENTS AND METHODS: Digital impression was taken with an intraoral optical scanner (CS3500, Carestream Dental, Atlanta, GA, USA). A prosthetic rehabilitation was realized on natural teeth using monolithic zirconia from 1.6 to 1.4 and from 2.7 to 2.4 frameworks, while in the aesthetic area (from 2.3 to 1.3), technicians left on the structure a 0.8 mm vestibular space for ceramic layering. DISCUSSION: The combination of digital impression technology and the use of the monolithic zirconia had demonstrated the delivery of the final prosthetic device in a quick time without the need to remodel functional or aesthetic areas. The digital work-flow combines intraoral optical impression techniques and CAD/CAM technology, in order to achieve a fully digital and successful way to deliver prosthetic restorations to patients, providing aesthetics and function in shorter intervals of time. The clinical outcome of this study was satisfactory but a long-term evaluation is needed.


Subject(s)
Computer-Aided Design , Dental Impression Technique , Dental Prosthesis Design , Aged , Humans , Male , Zirconium
SELECTION OF CITATIONS
SEARCH DETAIL
...