Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
2.
Eur Spine J ; 33(3): 1098-1108, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38153529

ABSTRACT

PURPOSE: This study aimed to establish a nomogram to predict the risk of venous thromboembolism (VTE), identifying potential risk factors, and providing theoretical basis for prevention of VTE after spinal surgery. METHODS: A retrospective analysis was conducted on 2754 patients who underwent spinal surgery. The general characteristics of the training group were initially screened using univariate logistic analysis, and the LASSO method was used for optimal prediction. Subsequently, multivariate logistic regression analysis was performed to identify independent risk factors for postoperative VTE in the training group, and a nomogram for predict risk of VTE was established. The discrimination, calibration, and clinical usefulness of the nomogram were separately evaluated using the C-index, receiver operating characteristic curve, calibration plot and clinical decision curve, and was validated using data from the validation group finally. RESULTS: Multivariate logistic regression analysis identified 10 independent risk factors for VTE after spinal surgery. A nomogram was established based on these independent risk factors. The C-index for the training and validation groups indicating high accuracy and stability of the model. The area under the receiver operating characteristic curve indicating excellent discrimination ability; the calibration curves showed outstanding calibration for both the training and validation groups. Decision curve analysis showed the clinical net benefit of using the nomogram could be maximized in the probability threshold range of 0.01-1. CONCLUSION: Patients undergoing spinal surgery with elevated D-dimer levels, prolonger surgical, and cervical surgery have higher risk of VTE. The nomogram can provide a theoretical basis for clinicians to prevent VTE.


Subject(s)
Nomograms , Venous Thromboembolism , Humans , Retrospective Studies , Venous Thromboembolism/epidemiology , Venous Thromboembolism/etiology , Venous Thromboembolism/prevention & control , Neurosurgical Procedures , Neck , Risk Factors
3.
Fa Yi Xue Za Zhi ; 39(4): 399-405, 2023 Aug 25.
Article in English, Chinese | MEDLINE | ID: mdl-37859480

ABSTRACT

The postmortem interval (PMI) estimation is a key and difficult point in the practice of forensic medicine, and forensic scientists at home and abroad have been searching for objective, quantifiable and accurate methods of PMI estimation. With the development and combination of high-throughput sequencing technology and artificial intelligence technology, the establishment of PMI model based on the succession of the microbial community on corpses has become a research focus in the field of forensic medicine. This paper reviews the technical methods, research applications and influencing factors of microbial community in PMI estimation explored by using high-throughput sequencing technology, to provide a reference for the related research on the use of microbial community to estimate PMI.


Subject(s)
Microbiota , Postmortem Changes , Humans , Artificial Intelligence , Autopsy , Cadaver
4.
Fa Yi Xue Za Zhi ; 38(1): 40-45, 2022 Feb 25.
Article in English, Chinese | MEDLINE | ID: mdl-35725702

ABSTRACT

OBJECTIVES: To explore the application values of diatom artificial intelligence (AI) search system in the diagnosis of drowning. METHODS: The liver and kidney tissues of 12 drowned corpses were taken and were performed with the diatom test, the view images were obtained by scanning electron microscopy (SEM). Diatom detection and forensic expert manual identification were carried out under the thresholds of 0.5, 0.7 and 0.9 of the diatom AI search system, respectively. Diatom recall rate, precision rate and image exclusion rate were used to detect and compare the efficiency of diatom AI search system. RESULTS: There was no statistical difference between the number of diatoms detected in the target marked by the diatom AI search system and the number of diatoms identified manually (P>0.05); the recall rates of the diatom AI search system were statistically different under different thresholds (P<0.05); the precision rates of the diatom AI system were statistically different under different thresholds(P<0.05), and the highest precision rate was 53.15%; the image exclusion rates of the diatom AI search system were statistically different under different thresholds (P<0.05), and the highest image exclusion rate was 99.72%. For the same sample, the time taken by the diatom AI search system to identify diatoms was only 1/7 of that of manual identification. CONCLUSIONS: Diatom AI search system has a good application prospect in drowning cases. Its automatic diatom search ability is equal to that of experienced forensic experts, and it can greatly reduce the workload of manual observation of images.


Subject(s)
Diatoms , Drowning , Artificial Intelligence , Drowning/diagnosis , Humans , Liver , Lung , Microscopy, Electron, Scanning
5.
Fa Yi Xue Za Zhi ; 38(1): 67-70, 2022 Feb 25.
Article in English, Chinese | MEDLINE | ID: mdl-35725706

ABSTRACT

OBJECTIVES: To study whether diatoms can enter the body through the lymphatic system of the digestive tract. METHODS: Twenty experimental rabbits were divided into the test group and the control group randomly, and intragastric administration was performed with 20 mL water sample from the Pearl River and 20 mL ultrapure water, respectively. After 30 min, lymph, lungs, livers and kidneys were extracted for the diatom test. The concentration, size and type of diatoms were recorded. RESULTS: The concentration of diatoms of the test group was higher than that of the control group (P<0.05). In the test group, Stephanodiscus, Coscinodiscus, Cyclotella, Melosira, Nitzschia, Synedra, Cymbella, and Navicula were detected; in the control group, Stephanodiscus, Coscinodiscus and Cyclotella were detected. The long diameter and the short diameter of diatoms of the test group were higher than those of the control group (P<0.05). In the test group, 1-2 diatoms were detected in 3 lung samples and 2 liver samples, which were Stephanodiscus or Cyclotella, and no diatoms were detected in the kidney samples; in the control group, 1-2 diatoms were detected in 2 lung samples and 3 liver samples, which were Stephanodiscus or Coscinodiscus, and no diatoms were detected in the kidney samples. CONCLUSIONS: Diatoms can enter the body through the lymphatic fluid, which is one of the reasons for the presence of diatoms in tissues and organs of non-drowning cadavers.


Subject(s)
Diatoms , Drowning , Animals , Gastrointestinal Tract , Lung , Lymphatic System , Rabbits , Water/metabolism
6.
Fa Yi Xue Za Zhi ; 38(1): 77-81, 2022 Feb 25.
Article in English, Chinese | MEDLINE | ID: mdl-35725708

ABSTRACT

OBJECTIVES: To study the effects of temperature and time for diatoms digestion and find out suitable digestive temperature and time. METHODS: Eighty pieces of liver tissues were collected, each piece of tissue was 2 g, and 2 mL Pearl River water was added to each piece of tissue. The digestion temperature was set at 100 ℃, 120 ℃, 140 ℃, 160 ℃, 180 ℃ and the digestion time was set at 40, 50, 60, 70, 80 min. The liver tissue and water mixture were divided into 8 portions in each group. All the samples were tested by microwave digestive - vacuum filtration - automated scanning electron microscopy method. The quantity of diatom recovered and the quality of residue on the membrane were recorded. RESULTS: When the digestion time was set to 60 min, there were statistically significant differences in the number of diatoms recovered at different temperatures (P<0.05). The maximum number of diatoms recovered was (28 797.50±6 009.67) at 140 ℃, and the minimum residue was (0.60±0.28) mg at 180 ℃. When the digestion temperature was set at 140 ℃, there were statistically significant differences in the number of diatoms recovered at different digestion times (P<0.05). The number of diatoms recovered was the highest at 40 min, it was up to (20 650.88±1 950.29), and the residue quality of each group had no statistical significance among different digestion time groups(P>0.05). CONCLUSIONS: The effect of diatom digestion is related to temperature and time. When the digestion temperature was 140 ℃ and the digestion time was 40, 50 and 60 min, it is favorable for diatom test.


Subject(s)
Diatoms , Drowning , Forensic Pathology/methods , Temperature , Water
7.
Fa Yi Xue Za Zhi ; 38(1): 114-118, 2022 Feb 25.
Article in English, Chinese | MEDLINE | ID: mdl-35725714

ABSTRACT

OBJECTIVES: To compare the application effect of microwave digestion - vacuum filtration - automated scanning electron microscopy (MD-VF-Auto SEM) method and plankton gene multiplex PCR system in the diagnosis of drowning. METHODS: Lung, liver and kidney tissue of 10 non-drowning cases and 50 drowning cases were prepared for further MD-VF-Auto SEM method analysis and plankton gene multiplex PCR system analysis. The positive detection rate of the two methods in each tissue was calculated. RESULTS: The positive rate of the MD-VF-Auto SEM method detecting diatoms in drowning cases was 100%, and few diatoms were detected in the liver and kidney tissues of 6 non-drowning cases. By using the plankton gene multiplex PCR system, the diatom positive rate of drowning cases was 84%, and all the non-drowning cases were negative. There were significant differences in the positive rate of the liver, kidney tissues between MD-VF-Auto SEM method and plankton gene multiplex PCR system (P<0.05), as well as the total positive rate of cases. However, no significant differences were found in the positive rates of lung tissues (P>0.05). CONCLUSIONS: MD-VF-Auto SEM method is more sensitive than plankton gene multiplex PCR system in diatom test. But the plankton gene multiplex PCR system can also detect plankton other than diatoms. Combination of the two methods can provide a more reliable basis for the diagnosis of drowning.


Subject(s)
Diatoms , Drowning , Diatoms/genetics , Drowning/diagnosis , Humans , Liver , Lung , Microscopy, Electron, Scanning , Multiplex Polymerase Chain Reaction , Plankton/genetics
8.
Fa Yi Xue Za Zhi ; 38(1): 110-113, 2022 Feb 25.
Article in English, Chinese | MEDLINE | ID: mdl-35725713

ABSTRACT

OBJECTIVES: To retrospectively analyze diatom test cases of corpses in water and discuss the value of quantitative analysis of diatoms in the diagnosis of drowning. METHODS: A total of 490 cases of water-related death were collected. They were divided into drowning group and postmortem immersion group according to the cause of death. Diatoms in lung, liver, kidney tissue and water sample were analyzed quantitatively by microwave digestion-vacuum filtration-automated scanning electron microscopy (MD-VF-Auto SEM) method. The ratios of content of diatoms in lung tissue and water sample (CL/CD) were calculated. RESULTS: The results of diatom test for three organs (lung, liver and kidney) were all positive in 400 cases (85.5%); the content of diatom in lung, liver, kidney tissues, and water samples of drowning group were (113 235.9±317 868.1), (26.7±75.6), (23.3±52.2) and (12 113.3±21 760.0) cells/10 g, respectively; the species of diatom were (7.5±2.8), (2.6±1.9), (2.9±2.1) and (8.9±3.0) types, respectively; the CL/CD of drowning group and postmortem immersion group were (100.6±830.7) and (0.3±0.4), respectively. CONCLUSIONS: Quantitative analysis of diatoms can provide supportive evidence for the diagnosis of drowning, and the parameter CL/CD can be introduced into the analysis to make a more accurate diagnosis of drowning.


Subject(s)
Diatoms , Drowning , Autopsy , Drowning/diagnosis , Humans , Lung , Retrospective Studies , Water
9.
Orthop Surg ; 14(3): 522-529, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35098677

ABSTRACT

OBJECTIVE: To evaluate the placement feasibility and safety of the newly designed retropharyngeal reduction plate by cadaveric test and to perform morphometric trajectory analysis. METHODS: The five cadaveric specimens with intact atlantoaxial joint were enrolled in this study. They were used for simulating the placement process and evaluating the placement feasibility of the retropharyngeal reduction plate. The atlantoaxial dislocation (AAD) of five cadaveric specimens were obtained by proper external force after dissecting ligaments. The retropharyngeal reduction plate was placed on atlantoaxial joint of cadaveric specimens. The X-ray and three-dimensional (3D) spiral CT were used for evaluating the placement safety of retropharyngeal reduction plate. The DICOM data was obtained after 3D spiral CT scanning for the morphometric trajectory analysis. RESULTS: The reduction plates were successfully placed on the atlantoaxial joint of five cadaveric specimens through the retropharyngeal approach, respectively. The X-ray and 3D spiral CT showed the accurate screw implantation and satisfying plate placement. The length of the left/right atlas screw trajectory (L/RAT) was, respectively, 1.73 ± 0.01 cm (LAT) and 1.71 ± 0.02 cm (RAT). The length of odontoid screw trajectory (OST) was 1.38 ± 0.02 cm. The length of the left/right axis screw trajectory (L/RAXT) was, respectively, 1.67 ± 0.02 cm (LAXT) and 1.67 ± 0.01 cm (RAXT). There was no statistical significance between left side and right side in terms of AT and AXT (P > 0.05). The angles of atlas screw trajectory angle (ASTA), axis screw trajectory angle (AXSTA), and odontoid screw trajectory angle (OSTA) were 38.04° ± 2.03°, 56.92° ± 2.66°, and 34.78° ± 2.87°, respectively. CONCLUSION: The cadaveric test showed that the retropharyngeal reduction plate is feasible to place on the atlantoaxial joint, which is also a safe treatment choice for atlantoaxial dislocation. The meticulous preoperative planning of screw trajectory based on individual differences was also vital to using this technique.


Subject(s)
Atlanto-Axial Joint , Joint Dislocations , Spinal Fusion , Atlanto-Axial Joint/diagnostic imaging , Atlanto-Axial Joint/surgery , Bone Plates , Bone Screws , Cadaver , Humans , Joint Dislocations/diagnostic imaging , Joint Dislocations/surgery , Tomography, X-Ray Computed
10.
Orthop Surg ; 12(3): 931-937, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32495510

ABSTRACT

OBJECTIVES: Occipitocervical fusion (OCF) is an effective treatment for instability of occipitocervical junction (OCJ). The occipital condyle screw serves as a novel surgical technique for occipitocervical fixation. However, the intraoperative procedures for the occipital condyle screw technique have relied on surgeons' experience, so the pool of surgeons who are able to perform this surgery safely is limited. The present study aims to evaluate the feasibility and safety of the occipital condyle screw technique using human cadavers and to provide image anatomy for clinical application basis. METHODS: The scientific study comprised 10 fresh-frozen cadaveric specimens from the anatomy department of Qingdao University. Placement of the occipital condyle screws (3.5 mm diameter and 20.0 mm length) was performed in the 10 fresh-frozen cadaveric specimens with intact occipitocervical junctions, respectively. Occipitocervical CT was performed for all specimens and the DICOM data was obtained. Occipitocervical CT three-dimensional (3D) reconstruction was performed for the cadavers. Morphometric analysis was performed on the bilateral occipitocervical junction of 10 cadaveric specimens based on the 3D reconstruction CT images. Detailed morphometric measurements of the 20 occipital condyles screws were conducted including the average length of the screw trajectory, inside and upper tilting angles of screws, distance to the hypoglossal canal, and to the medial wall of occipital condyle. RESULTS: Placement of the occipital condyle screws into the 20 occipital condyles of the 10 cadaveric specimens was performed successfully and the trajectory of implantation was satisfactory according to 3D CT reconstruction images, respectively. There was no obvious injury to the spinal cord, nerve root, and vertebral artery. The length of the bilateral screw trajectory was, respectively, 20.96 ± 0.91 mm (left) and 20.59 ± 0.77 mm (right) (t = 1.306, P > 0.05). The upper tilting angle of bilateral screws was, respectively, 11.24° ± 0.74° (left) and 11.11° ± 0.64° (right) (t = 0.681, P > 0.05). The inside tilting angle of bilateral screws was, respectively, 31.00° ± 1.32° (left) and 30.85° ± 1.27° (right) (t = 0.307, P > 0.05). The screw's distance to the bilateral hypoglossal canal was, respectively, 4.84 ± 0.54 mm (left) and 4.70 ± 0.54 mm (right) (t = 0.685, P > 0.05). The screw's distance to the medial wall of the bilateral occipital condyle was, respectively, 5.13 ± 0.77 mm (left) and 5.04 ± 0.71 mm (right) (t = 0.384, P > 0.05). CONCLUSION: The occipital condyle screw technique can serve as a feasible and safe treatment for instability of the occipitocervical junction with meticulous preoperative planning of the screw entry point and direction based on individual differences. Morphometric trajectory analysis is also an effective way to evaluate the surgical procedure.


Subject(s)
Bone Screws , Cervical Vertebrae/surgery , Joint Instability/surgery , Occipital Bone/surgery , Spinal Fusion/methods , Cadaver , Cervical Vertebrae/diagnostic imaging , Feasibility Studies , Humans , Imaging, Three-Dimensional , Occipital Bone/diagnostic imaging , Tomography, X-Ray Computed
11.
Biomed Environ Sci ; 30(4): 255-263, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28494835

ABSTRACT

OBJECTIVE: To assess the test-retest reliability and criterion validity of the Simplified Chinese-character version of the International Physical Activity Questionnaire Long form (IPAQ-L) in urban community-dwelling adults in Hanghzou, China. METHODS: A total of 158 eligible participants aged 25-59 years from 6 neighbourhoods in two central districts of Hangzhou completed the IPAQ-L questionnaire twice within a 7-day interval. Half of the subjects wore pedometers during the first 7 days. Test-retest reliability was examined by comparing the first (Day 1) and the second (Day 9) survey of IPAQ-L. Criterion validity was assessed by comparing IPAQ-L with pedometer data. RESULTS: Modest to good test-retest reliability was found with intraclass correlation coefficients of 0.67 for total PA, 0.37 to 0.73 for specific dimensions, and 0.56 to 0.71 for different intensities of PA. Total PA measured by IPAQ-L was moderately correlated with exercise levels (partial r = 0.27, P = 0.020) and walking distance (partial r = 0.31, P = 0.007), which were measured by a pedometer, after adjusting for gender, age, educational attainment and employment status. CONCLUSION: Our results indicate that the IPAQ-L is a reliable and validated measure for assessing physical activity levels in this population and possibly the adult population in other mainland Chinese cities.


Subject(s)
Exercise , Surveys and Questionnaires/standards , Adult , China , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Reproducibility of Results , Urban Population/statistics & numerical data
12.
BMC Public Health ; 14: 109, 2014 Feb 04.
Article in English | MEDLINE | ID: mdl-24495676

ABSTRACT

BACKGROUND: Some aspects of the neighborhood built environment may influence residents' physical activity, which in turn, affects their health. This study aimed to develop an urban built environment evaluation tool and conduct necessary reliability and validity tests. METHODS: A 41-item urban built environment scan tool was developed to objectively assess the neighborhood built environment features related to physical activity. Six neighborhoods in Hangzhou were selected from three types of administrative planning units. A pair of auditors independently assessed all of the 205 street segments at the same time. Half of the segments (n = 104) were audited twice by the same auditor after a two-week time interval. Inter-rater reliability was assessed by comparing the audits of paired observers, while intra-rater reliability was evaluated by comparing an auditor's repeated assessments of the same segments. The construct validity was tested using factor analysis. RESULTS: The inter-rater reliability for most items was above 0.8. The intra-rater reliability for most items was above 0.4, and was lower than corresponding inter-rater reliability. Six factors were extracted by factor analysis and the factor loading matrix showed good construct validity. CONCLUSIONS: The CUBEST is a reliable and valid instrument that can be used to assess the physical activity-related built environment in Hangzhou, and potentially other cities in China.


Subject(s)
Environment Design/standards , Motor Activity , China , Factor Analysis, Statistical , Humans , Observer Variation , Reproducibility of Results
15.
Zhonghua Nei Ke Za Zhi ; 49(12): 1006-9, 2010 Dec.
Article in Chinese | MEDLINE | ID: mdl-21211356

ABSTRACT

OBJECTIVE: To discuss the levels of evidence provided by different study designs. METHODS: Websites of N Engl J Med, JAMA, Lancet, and BMJ were accessed to identify research articles (systematic review and meta-analysis included) published in 2009. A standardized data collection form was established using Epidata 3.1 software to extract the "title", "country of lead author", "clinical problem" (such as treatment, diagnosis, etc.) and "study design" of eligible studies. Descriptive statistics was conducted with SPSS 13.0. RESULTS: Over all, 844 studies were included, among which 35.7% were RCT, 9.4% systematic review and Meta-analysis, and 54.9% other types of studies. Regarding clinical problems, 34.2%, 19.7%, 13.7%, 6.0% and 5.1% of the included researches addressed the issues of treatment, etiology/risk factors, prevention, disease frequency and prognosis, respectively. The study designs that were most frequently adopted to explore these problems were RCT (70.6%), cohort study (44.6%), RCT (68.1%), cross-sectional study (56.9%), and cohort study (93.0%), respectively. CONCLUSIONS: High-level evidence does not come exclusively from RCT and systematic review, as each type of study may have its unique value in health related research. The clinical problem of interest, the previous work that has been done to approach the same issue, as well as other factors should be taken into account when deciding whether the selected study design is appropriate.


Subject(s)
Periodicals as Topic , Research Design , Journalism, Medical , Meta-Analysis as Topic , Randomized Controlled Trials as Topic , Research Design/statistics & numerical data , Review Literature as Topic
SELECTION OF CITATIONS
SEARCH DETAIL
...