1.
EJNMMI Phys ; 11(1): 38, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38647987

ABSTRACT

BACKGROUND: In order to ensure adequate radiation protection of critical groups such as staff, caregivers and the general public coming into proximity of nuclear medicine (NM) patients, it is necessary to consider the impact of the radiation emitted by the patients during their stay at the hospital or after leaving the hospital. Current risk assessments are based on ambient dose rate measurements in a single position at a specified distance from the patient and carried out at several time points after administration of the radiopharmaceutical to estimate the whole-body retention. The limitations of such an approach are addressed in this study by developing and validating a more advanced computational dosimetry approach using Monte Carlo (MC) simulations in combination with flexible and realistic computational phantoms and time activity distribution curves from reference biokinetic models. RESULTS: Measurements of the ambient dose rate equivalent H*(10) at 1 m from the NM patient have been successfully compared against MC simulations with 5 different codes using the ICRP adult reference computational voxel phantoms, for typical clinical procedures with 99mTc-HDP/MDP, 18FDG and Na131I. All measurement data fall in the 95% confidence intervals, determined for the average simulated results. Moreover, the different MC codes (MCNP-X, PHITS, GATE, GEANT4, TRIPOLI-4®) have been compared for a more realistic scenario where the effective dose rate E of an exposed individual was determined in positions facing and aside the patient model at 30 cm, 50 cm and 100 cm. The variation between codes was lower than 8% for all the radiopharmaceuticals at 1 m, and varied from 5 to 16% for the face-to face and side-by-side configuration at 30 cm and 50 cm. A sensitivity study on the influence of patient model morphology demonstrated that the relative standard deviation of H*(10) at 1 m for the range of included patient models remained under 16% for time points up to 120 min post administration. CONCLUSIONS: The validated computational approach will be further used for the evaluation of effective dose rates per unit administered activity for a variety of close-contact configurations and a range of radiopharmaceuticals as part of risk assessment studies. Together with the choice of appropriate dose constraints this would facilitate the setting of release criteria and patient restrictions.

2.
Nat Med ; 29(12): 3111-3119, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37946058

ABSTRACT

Over one million European children undergo computed tomography (CT) scans annually. Although moderate- to high-dose ionizing radiation exposure is an established risk factor for hematological malignancies, risks at CT examination dose levels remain uncertain. Here we followed up a multinational cohort (EPI-CT) of 948,174 individuals who underwent CT examinations before age 22 years in nine European countries. Radiation doses to the active bone marrow were estimated on the basis of body part scanned, patient characteristics, time period and inferred CT technical parameters. We found an association between cumulative dose and risk of all hematological malignancies, with an excess relative risk of 1.96 (95% confidence interval 1.10 to 3.12) per 100 mGy (790 cases). Similar estimates were obtained for lymphoid and myeloid malignancies. Results suggest that for every 10,000 children examined today (mean dose 8 mGy), 1-2 persons are expected to develop a hematological malignancy attributable to radiation exposure in the subsequent 12 years. Our results strengthen the body of evidence of increased cancer risk at low radiation doses and highlight the need for continued justification of pediatric CT examinations and optimization of doses.


Subject(s)
Hematologic Neoplasms , Neoplasms, Radiation-Induced , Radiation Exposure , Humans , Child , Adolescent , Young Adult , Adult , Radiation Dosage , Neoplasms, Radiation-Induced/epidemiology , Neoplasms, Radiation-Induced/etiology , Neoplasms, Radiation-Induced/pathology , Hematologic Neoplasms/epidemiology , Hematologic Neoplasms/etiology , Radiation Exposure/adverse effects , Tomography, X-Ray Computed/adverse effects
3.
Front Oncol ; 13: 1222800, 2023.
Article in English | MEDLINE | ID: mdl-37795436

ABSTRACT

Background: In radiotherapy, especially when treating children, minimising exposure of healthy tissue can prevent the development of adverse outcomes, including second cancers. In this study we propose a validated Monte Carlo framework to evaluate the complete patient exposure during paediatric brain cancer treatment. Materials and methods: Organ doses were calculated for treatment of a diffuse midline glioma (50.4 Gy with 1.8 Gy per fraction) on a 5-year-old anthropomorphic phantom with 3D-conformal radiotherapy, intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and intensity modulated pencil beam scanning (PBS) proton therapy. Doses from computed tomography (CT) for planning and on-board imaging for positioning (kV-cone beam CT and X-ray imaging) accounted for the estimate of the exposure of the patient including imaging therapeutic dose. For dose calculations we used validated Monte Carlo-based tools (PRIMO, TOPAS, PENELOPE), while lifetime attributable risk (LAR) was estimated from dose-response relationships for cancer induction, proposed by Schneider et al. Results: Out-of-field organ dose equivalent data of proton therapy are lower, with doses between 0.6 mSv (testes) and 120 mSv (thyroid), when compared to photon therapy revealing the highest out-of-field doses for IMRT ranging between 43 mSv (testes) and 575 mSv (thyroid). Dose delivered by CT ranged between 0.01 mSv (testes) and 72 mSv (scapula) while a single imaging positioning ranged between 2 µSv (testes) and 1.3 mSv (thyroid) for CBCT and 0.03 µSv (testes) and 48 µSv (scapula) for X-ray. Adding imaging dose from CT and daily CBCT to the therapeutic demonstrated an important contribution of imaging to the overall radiation burden in the course of treatment, which is subsequently used to predict the LAR, for selected organs. Conclusion: The complete patient exposure during paediatric brain cancer treatment was estimated by combining the results from different Monte Carlo-based dosimetry tools, showing that proton therapy allows significant reduction of the out-of-field doses and secondary cancer risk in selected organs.

4.
Phys Med ; 107: 102543, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36780792

ABSTRACT

PURPOSE: To evaluate the effectiveness of currently available radioprotective (RP) devices in reducing the dose to interventional cardiology staff, especially to the eye lens and brain. METHODS: The performances of five RP devices (masks, caps, patient drapes, staff lead and lead-free aprons and Zero-Gravity (ZG) suspended radiation protection system) were assessed by means of Monte Carlo (MC) simulations. A geometry representative of an interventional cardiology setup was modelled and several configurations, including beam projections and staff distance from the source, were investigated. In addition, measurements on phantoms were performed for masks and drapes. RESULTS: An average dose reduction of 65% and 25% to the eyes and the brain respectively was obtained for the masks by MC simulations but a strong influence of the design was observed. The cap effectiveness for the brain ranges on average between 13% and 37%. Nevertheless, it was shown that only some upper parts of the brain were protected. There was no significant difference between the effectiveness of lead and lead-free aprons. Of all the devices, the ZG system offered the highest protection to the brain and eye lens and a protection level comparable to the apron for the organs normally covered. CONCLUSION: All investigated devices showed potential for dose reduction to specific organs. However, for masks, caps and drapes, it strongly depends on the design, exposure conditions and staff position. Therefore, for a clinical use, it is recommended to evaluate their effectiveness in the planned conditions of use.


Subject(s)
Cardiology , Lens, Crystalline , Occupational Exposure , Radiation Exposure , Radiation Protection , Humans , Radiation Protection/methods , Radiometry/methods , Radiation Dosage , Radiation Exposure/prevention & control , Cardiology/methods , Occupational Exposure/prevention & control , Radiology, Interventional/methods
5.
J Radiol Prot ; 43(1)2023 02 01.
Article in English | MEDLINE | ID: mdl-36633569

ABSTRACT

INTRODUCTION: Although the use of68Ga has increased substantially in nuclear medicine over the last decade, there is limited information available on occupational exposure due to68Ga. The purpose of this study is to determine the occupational extremity exposure during the preparation, dispensing and administration of68Ga-labelled radiopharmaceuticals. METHOD: Workers in eight centres wore a ring dosimeter for all tasks involving68Ga-labelled radiopharmaceuticals for a minimum of one month. Additionally, the fingertip dose was monitored in two centres and the hand with the highest ring dose during68Ga procedures was also identified in one centre. RESULTS: The median normalised ring dose for68Ga procedures was found to be 0.25 mSv GBq-1(range 0.01-3.34). The normalised68Ga ring doses recorded in this study are similar to that found in the literature for18F. This study is consistent with previous findings that the highest extremity dose is found on the non-dominant hand. A limited sub study in two of the centres showed a median fingertip to base of the finger dose ratio of 4.3. Based on this median ratio, the extrapolated annual68Ga fingertip dose for 94% of the workers monitored in this study would be below Category B dose limit (150 mSv) and no worker would exceed Category A dose limit (500 mSv). CONCLUSION: When appropriate shielding and radiation protection practices are employed, the extremity dose due to68Ga is comparable to that of18F and is expected to be well below the regulatory limits for the majority of workers.


Subject(s)
Occupational Exposure , Radiopharmaceuticals , Humans , Pilot Projects , Pharmaceutical Preparations , Fingers , Positron-Emission Tomography , Occupational Exposure/analysis , Radiation Dosage
6.
Q J Nucl Med Mol Imaging ; 67(1): 29-36, 2023 03.
Article in English | MEDLINE | ID: mdl-36630081

ABSTRACT

BACKGROUND: Extremity exposure during the handling of unsealed radioactive sources is a matter of concern for nuclear medicine workers. Next to 99mTc and 18F, other radiopharmaceuticals have seen an increase in their use over the last decade. However, limited information on their impact on extremity dose is available. This study aimed to gain insight into the status of extremity exposure and dose monitoring in Europe. METHODS: A survey was conducted at the end of 2020 among the European Association of Nuclear Medicine community. It contained 24 questions considering department characteristics, worker tasks, dosimeter use, typical worker extremity dose, department workload for selected radionuclides (99mTc, 18F, 68Ga, 177Lu, 90Y) and protective measures. RESULTS: A total of 106 replies were received, 92% of which were from Europe. About half of the respondents were from academic hospitals. Ninety-nine departments implement extremity dose monitoring for a total of 1335 workers. Most workers (95%) wear a ring dosimeter, generally on the non-dominant hand, and 44% on the index finger. Monthly doses were generally low (median values at different ring position: 0.4-1.8 mSv), although higher doses were reported (20.8-38.8 mSv). About 1/3 of workers performed the full task range (preparation, dispensing, and administration). Administration is associated with significantly lower extremity doses. Interestingly, no correlation between department workload and collective dose was found. The adoption of vial and syringe shielding, as well as distance tools, was common. The workers dispensing 99mTc without syringe shielding or PET nuclides without automated system received a significantly higher dose. Handling 68Ga, 177Lu and 90Y did not appear to have an impact on the reported doses. CONCLUSIONS: Protective measures play a significant role in lowering extremity doses, while department workload and more recently introduced radionuclides seem not to be major dose determinants.


Subject(s)
Nuclear Medicine , Humans , Radiation Dosage , Gallium Radioisotopes , Radioisotopes , Extremities
7.
J Radiol Prot ; 43(1)2023 02 17.
Article in English | MEDLINE | ID: mdl-36720155

ABSTRACT

The International Commission on Radiation Units and Measurements (ICRU) proposed a new set of operational quantities for radiation protection for external radiation in its Report Committee 26 (ICRU95). The new proposal aims to improve the coherence between the operational quantities and the definitions of the protection quantities in the recommendations of the International Commission on Radiological Protection set out in 2007 (Ann. ICRP37). It is expected that this change in operational quantities will impact current dosimeter designs. Although for many photon energies, the conversion coefficients from physical field quantities to the new operational quantities will change relatively little, for radiation fields with low energy photon components, such as medical x-ray applications, there will be a significant decrease in the values of the conversion coefficients. This means that the numerical values of the new operational quantities will be much lower for the same radiation field. These values will be closer to the effective dose, but this change can still cause confusion for medical staff. It is important to examine the effect of the new set of dose conversion coefficients on the personal dose in realistic radiation fields. We performed a study to assess the effect of changing the definition of the operational quantity, personal dose equivalent (Hp), in realistic radiation fields in interventional radiology (IR) workplaces. The x-ray tube kilovoltage peak (kVp) in IR ranges between 60 and 120 kV. The medical staff is exposed to the scattered photons which have a wide range of energies depending on the beam configuration and the patient size. The objective of this study is to 'quantitatively' estimate the impact of implementing the new ICRU quantities of Report 95 in IR radiation fields using Monte Carlo simulations. Simulations of 560 different configurations in IR were performed using MCNPX to calculate fluence binned per energy and angle of incidence.HpandHp(10)were then calculated for each configuration using dose conversion coefficients from fluence given by ICRU Reports 95 and 57, respectively. The results show that the mean of the ratio,Hp(10)/Hp, is 1.6 for all simulated scenarios. This reduction will correct the current overestimation of the effective dose and should result in better compliance with the dose limits in IR. However, it may also have negative consequences on the safety culture among the medical staff. Special care will be needed when interpreting these lower doses.


Subject(s)
Radiation Protection , Radiology, Interventional , Humans , Radiation Dosage , Computer Simulation , Radiation Protection/methods , Photons , Monte Carlo Method , Radiometry/methods
8.
Acta Radiol ; 64(1): 125-138, 2023 Jan.
Article in English | MEDLINE | ID: mdl-34935520

ABSTRACT

BACKGROUND: Optimizing patient exposure in interventional cardiology is key to avoid skin injuries. PURPOSE: To establish predictive models of peak skin dose (PSD) during percutaneous coronary intervention (PCI), chronic total occlusion percutaneous coronary intervention (CTO), and transcatheter aortic valve implantation (TAVI) procedures. MATERIAL AND METHODS: A total of 534 PCI, 219 CTO, and 209 TAVI were collected from 12 hospitals in eight European countries. Independent associations between PSD and clinical and technical dose determinants were examined for those procedures using multivariate statistical analysis. A priori and a posteriori predictive models were built using stepwise multiple linear regressions. A fourfold cross-validation was performed, and models' performance was evaluated using the root mean square error (RMSE), mean absolute percentage error (MAPE), coefficient of determination (R²), and linear correlation coefficient (r). RESULTS: Multivariate analysis proved technical parameters to overweight clinical complexity indices with PSD mainly affected by fluoroscopy time, tube voltage, tube current, distance to detector, and tube angulation for PCI. For CTO, these were body mass index, tube voltage, and fluoroscopy contribution. For TAVI, these parameters were sex, fluoroscopy time, tube voltage, and cine acquisitions. When benchmarking the predictive models, the correlation coefficients were r = 0.45 for the a priori model and r = 0.89 for the a posteriori model for PCI. These were 0.44 and 0.67, respectively, for the CTO a priori and a posteriori models, and 0.58 and 0.74, respectively, for the TAVI a priori and a posteriori models. CONCLUSION: A priori predictive models can help operators estimate the PSD before performing the intervention while a posteriori models are more accurate estimates and can be useful in the absence of skin dose mapping solutions.


Subject(s)
Cardiology , Percutaneous Coronary Intervention , Humans , Radiation Dosage , Skin , Research Design , Cardiology/methods , Fluoroscopy , Coronary Angiography , Treatment Outcome , Radiography, Interventional
9.
Acta Radiol ; 64(1): 108-118, 2023 Jan.
Article in English | MEDLINE | ID: mdl-34958271

ABSTRACT

BACKGROUND: Patients can be exposed to high skin doses during complex interventional cardiology (IC) procedures. PURPOSE: To identify which clinical and technical parameters affect patient exposure and peak skin dose (PSD) and to establish dose reference levels (DRL) per clinical complexity level in IC procedures. MATERIAL AND METHODS: Validation and Estimation of Radiation skin Dose in Interventional Cardiology (VERIDIC) project analyzed prospectively collected patient data from eight European countries and 12 hospitals where percutaneous coronary intervention (PCI), chronic total occlusion PCI (CTO), and transcatheter aortic valve implantation (TAVI) procedures were performed. A total of 62 clinical complexity parameters and 31 technical parameters were collected, univariate regressions were performed to identify those parameters affecting patient exposure and define DRL accordingly. RESULTS: Patient exposure as well as clinical and technical parameters were collected for a total of 534 PCI, 219 CTO, and 209 TAVI. For PCI procedures, body mass index (BMI), number of stents ≥2, and total stent length >28 mm were the most prominent clinical parameters, which increased the PSD value. For CTO, these were total stent length >57 mm, BMI, and previous anterograde or retrograde technique that failed in the same session. For TAVI, these were male sex, BMI, and number of diseased vessels. DRL values for Kerma-area product (PKA), air kerma at patient entrance reference point (Ka,r), fluoroscopy time (FT), and PSD were stratified, respectively, for 14 clinical parameters in PCI, 10 in CTO, and four in TAVI. CONCLUSION: Prior knowledge of the key factors influencing the PSD will help optimize patient radiation protection in IC.


Subject(s)
Cardiology , Percutaneous Coronary Intervention , Humans , Male , Female , Radiation Dosage , Radiography, Interventional/methods , Cardiology/methods , Europe , Fluoroscopy/methods , Coronary Angiography
10.
Lancet Oncol ; 24(1): 45-53, 2023 01.
Article in English | MEDLINE | ID: mdl-36493793

ABSTRACT

BACKGROUND: The European EPI-CT study aims to quantify cancer risks from CT examinations of children and young adults. Here, we assess the risk of brain cancer. METHODS: We pooled data from nine European countries for this cohort study. Eligible participants had at least one CT examination before age 22 years documented between 1977 and 2014, had no previous diagnosis of cancer or benign brain tumour, and were alive and cancer-free at least 5 years after the first CT. Participants were identified through the Radiology Information System in 276 hospitals. Participants were linked with national or regional registries of cancer and vital status, and eligible cases were patients with brain cancers according to WHO International Classification of Diseases for Oncology. Gliomas were analysed separately to all brain cancers. Organ doses were reconstructed using historical machine settings and a large sample of CT images. Excess relative risks (ERRs) of brain cancer per 100 mGy of cumulative brain dose were calculated with linear dose-response modelling. The outcome was the first reported diagnosis of brain cancer after an exclusion period of 5 years after the first electronically recorded CT examination. FINDINGS: We identified 948 174 individuals, of whom 658 752 (69%) were eligible for our study. 368 721 (56%) of 658 752 participants were male and 290 031 (44%) were female. During a median follow-up of 5·6 years (IQR 2·4-10·1), 165 brain cancers occurred, including 121 (73%) gliomas. Mean cumulative brain dose, lagged by 5 years, was 47·4 mGy (SD 60·9) among all individuals and 76·0 mGy (100·1) among people with brain cancer. A significant linear dose-response relationship was observed for all brain cancers (ERR per 100 mGy 1·27 [95% CI 0·51-2·69]) and for gliomas separately (ERR per 100 mGy 1·11 [0·36-2·59]). Results were robust when the start of follow-up was delayed beyond 5 years and when participants with possibly previously unreported cancers were excluded. INTERPRETATION: The observed significant dose-response relationship between CT-related radiation exposure and brain cancer in this large, multicentre study with individual dose evaluation emphasises careful justification of paediatric CTs and use of doses as low as reasonably possible. FUNDING: EU FP7; Belgian Cancer Registry; La Ligue contre le Cancer, L'Institut National du Cancer, France; Ministry of Health, Labour and Welfare of Japan; German Federal Ministry of Education and Research; Worldwide Cancer Research; Dutch Cancer Society; Research Council of Norway; Consejo de Seguridad Nuclear, Generalitat de Catalunya, Spain; US National Cancer Institute; UK National Institute for Health Research; Public Health England.


Subject(s)
Brain Neoplasms , Glioma , Neoplasms, Radiation-Induced , Radiation Exposure , Child , Humans , Male , Female , Young Adult , Adult , Cohort Studies , Radiation Dosage , Neoplasms, Radiation-Induced/epidemiology , Neoplasms, Radiation-Induced/etiology , Neoplasms, Radiation-Induced/pathology , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/epidemiology , Brain Neoplasms/etiology , Glioma/diagnostic imaging , Glioma/epidemiology , Glioma/etiology , Radiation Exposure/adverse effects , Tomography, X-Ray Computed/adverse effects , Tomography, X-Ray Computed/methods
11.
Front Oncol ; 12: 882506, 2022.
Article in English | MEDLINE | ID: mdl-35875147

ABSTRACT

Background: The out-of-the-field absorbed dose affects the probability of primary second radiation-induced cancers. This is particularly relevant in the case of pediatric treatments. There are currently no methods employed in the clinical routine for the computation of dose distributions from stray radiation in radiotherapy. To overcome this limitation in the framework of conventional teletherapy with photon beams, two computational tools have been developed-one based on an analytical approach and another depending on a fast Monte Carlo algorithm. The purpose of this work is to evaluate the accuracy of these approaches by comparison with experimental data obtained from anthropomorphic phantom irradiations. Materials and Methods: An anthropomorphic phantom representing a 5-year-old child (ATOM, CIRS) was irradiated considering a brain tumor using a Varian TrueBeam linac. Two treatments for the same planned target volume (PTV) were considered, namely, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In all cases, the irradiation was conducted with a 6-MV energy beam using the flattening filter for a prescribed dose of 3.6 Gy to the PTV. The phantom had natLiF : Mg, Cu, P (MCP-N) thermoluminescent dosimeters (TLDs) in its 180 holes. The uncertainty of the experimental data was around 20%, which was mostly attributed to the MCP-N energy dependence. To calculate the out-of-field dose, an analytical algorithm was implemented to be run from a Varian Eclipse TPS. This algorithm considers that all anatomical structures are filled with water, with the exception of the lungs which are made of air. The fast Monte Carlo code dose planning method was also used for computing the out-of-field dose. It was executed from the dose verification system PRIMO using a phase-space file containing 3x109 histories, reaching an average standard statistical uncertainty of less than 0.2% (coverage factor k = 1 ) on all voxels scoring more than 50% of the maximum dose. The standard statistical uncertainty of out-of-field voxels in the Monte Carlo simulation did not exceed 5%. For the Monte Carlo simulation the actual chemical composition of the materials used in ATOM, as provided by the manufacturer, was employed. Results: In the out-of-the-field region, the absorbed dose was on average four orders of magnitude lower than the dose at the PTV. For the two modalities employed, the discrepancy between the central values of the TLDs located in the out-of-the-field region and the corresponding positions in the analytic model were in general less than 40%. The discrepancy in the lung doses was more pronounced for IMRT. The same comparison between the experimental and the Monte Carlo data yielded differences which are, in general, smaller than 20%. It was observed that the VMAT irradiation produces the smallest out-of-the-field dose when compared to IMRT. Conclusions: The proposed computational methods for the routine calculation of the out-of-the-field dose produce results that are similar, in most cases, with the experimental data. It has been experimentally found that the VMAT irradiation produces the smallest out-of-the-field dose when compared to IMRT for a given PTV.

12.
J Radiol Prot ; 42(3)2022 07 06.
Article in English | MEDLINE | ID: mdl-35654011

ABSTRACT

The lens of the eye can be damaged by ionising radiation, so individuals whose eyes are exposed to radiation during their work may need to protect their eyes from exposure. Lead glasses are widely available, but there are questions about their efficiency in providing eye protection. In this study, Monte Carlo simulations are used to assess the efficiency of lead glasses in protecting the sensitive volume of the eye lens. Two designs currently available for interventional cardiologists are a wraparound (WA) style and ones with flat frontal lenses with side shielding. These designs were considered together with four modifications that would impact upon their efficiency: changing the lead equivalent thickness, adding lead to the frames, elongating the frontal lenses, and adding a closing shield to the bottom rim. For the eye closest to the source, standard models of lead glasses only decrease the radiation reaching the most sensitive region of the eye lens by 22% or less. Varying the lead thickness between 0.4 mm and 0.75 mm had little influence on the protection provided in the simulation of clinical use, neither did adding lead to the frames. Improved shielding was obtained by elongating the frontal lens, which could reduce radiation reaching the eye lens by up to 76%. Glasses with lenses that had a rim at the base, extending towards the face of the user, also provided better shielding than current models, decreasing the dose by up to 80%. In conclusion, elongating the frontal lens of lead glasses, especially of the WA design, could provide a three-fold increase in shielding efficiency and this is still valid for lenses with 0.4 mm lead equivalence.


Subject(s)
Cardiologists , Lens, Crystalline , Occupational Exposure , Radiation Protection , Eye Protective Devices , Humans , Occupational Exposure/prevention & control , Radiation Dosage , Radiology, Interventional
13.
Front Oncol ; 12: 882489, 2022.
Article in English | MEDLINE | ID: mdl-35756661

ABSTRACT

Proton therapy enables to deliver highly conformed dose distributions owing to the characteristic Bragg peak and the finite range of protons. However, during proton therapy, secondary neutrons are created, which can travel long distances and deposit dose in out-of-field volumes. This out-of-field absorbed dose needs to be considered for radiation-induced secondary cancers, which are particularly relevant in the case of pediatric treatments. Unfortunately, no method exists in clinics for the computation of the out-of-field dose distributions in proton therapy. To help overcome this limitation, a computational tool has been developed based on the Monte Carlo code TOPAS. The purpose of this work is to evaluate the accuracy of this tool in comparison to experimental data obtained from an anthropomorphic phantom irradiation. An anthropomorphic phantom of a 5-year-old child (ATOM, CIRS) was irradiated for a brain tumor treatment in an IBA Proteus Plus facility using a pencil beam dedicated nozzle. The treatment consisted of three pencil beam scanning fields employing a lucite range shifter. Proton energies ranged from 100 to 165 MeV. A median dose of 50.4 Gy(RBE) with 1.8 Gy(RBE) per fraction was prescribed to the initial planning target volume (PTV), which was located in the cerebellum. Thermoluminescent detectors (TLDs), namely, Li-7-enriched LiF : Mg, Ti (MTS-7) type, were used to detect gamma radiation, which is produced by nuclear reactions, and secondary as well as recoil protons created out-of-field by secondary neutrons. Li-6-enriched LiF : Mg,Cu,P (MCP-6) was combined with Li-7-enriched MCP-7 to measure thermal neutrons. TLDs were calibrated in Co-60 and reported on absorbed dose in water per target dose (µGy/Gy) as well as thermal neutron dose equivalent per target dose (µSv/Gy). Additionally, bubble detectors for personal neutron dosimetry (BD-PND) were used for measuring neutrons (>50 keV), which were calibrated in a Cf-252 neutron beam to report on neutron dose equivalent dose data. The Monte Carlo code TOPAS (version 3.6) was run using a phase-space file containing 1010 histories reaching an average standard statistical uncertainty of less than 0.2% (coverage factor k = 1) on all voxels scoring more than 50% of the maximum dose. The primary beam was modeled following a Fermi-Eyges description of the spot envelope fitted to measurements. For the Monte Carlo simulation, the chemical composition of the tissues represented in ATOM was employed. The dose was tallied as dose-to-water, and data were normalized to the target dose (physical dose) to report on absorbed doses per target dose (mSv/Gy) or neutron dose equivalent per target dose (µSv/Gy), while also an estimate of the total organ dose was provided for a target dose of 50.4 Gy(RBE). Out-of-field doses showed absorbed doses that were 5 to 6 orders of magnitude lower than the target dose. The discrepancy between TLD data and the corresponding scored values in the Monte Carlo calculations involving proton and gamma contributions was on average 18%. The comparison between the neutron equivalent doses between the Monte Carlo simulation and the measured neutron doses was on average 8%. Organ dose calculations revealed the highest dose for the thyroid, which was 120 mSv, while other organ doses ranged from 18 mSv in the lungs to 0.6 mSv in the testes. The proposed computational method for routine calculation of the out-of-the-field dose in proton therapy produces results that are compatible with the experimental data and allow to calculate out-of-field organ doses during proton therapy.

14.
Int J Occup Med Environ Health ; 35(5): 549-560, 2022 Oct 03.
Article in English | MEDLINE | ID: mdl-35446304

ABSTRACT

OBJECTIVES: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap can lead to ambiguous results, a detailed study was performed. MATERIAL AND METHODS: The effectiveness of a lead free cap in reducing the doses to the skin was assessed in clinic by performing measurements with thermoluminescent dosimeters attached inside and outside the cap first during individual coronary angiography (CA) or CA/percutaneous transluminal coronary angioplasty (CA/PTCA) procedures and then cumulated during few procedures of the same type. In order to investigate the effect of the cap on reducing the doses to the brain additional measurements were performed with a male Alderson Rando and polymethyl methacrylate (PMMA) phantoms representing the physician and the patient, respectively for different projections. The brain dose per procedure, annual and cumulated during entire working practice were estimated for both cases working with and without the cap. RESULTS: The dose reduction factor (RF) for the skin (the quotient of doses outside and inside the cap) vary from 1.1 up to 4.0 in clinical conditions; on average 2.3-fold reduction is observed in the most exposed left temple. The RFs determined for the part of the head covered by the cap range from 1.4 to 1.8 while for the brain from 1.0 to 1.1 depending on the projection. The estimated annual brain dose for interventional cardiologist performing yearly 550 CA/PTCA procedures without any protective shields is 7.2 mGy and it is reduced with the lead free cap by an average factor of 1.1. CONCLUSIONS: The study results proved the considerable effectiveness of lead free cap to protect the skin but very limited to protect the brain. Int J Occup Med Environ Health. 2022;35(5):549-60.


Subject(s)
Cardiologists , Occupational Exposure , Coronary Angiography , Hemodynamics , Humans , Male , Occupational Exposure/prevention & control , Polymethyl Methacrylate , Radiation Dosage , Radiation, Ionizing
15.
Phys Med ; 93: 29-37, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34920380

ABSTRACT

INTRODUCTION: Interventional radiology procedures are associated with high skin dose exposure. The 2013/59/EURATOM Directive establishes that the equipment used for interventional radiology must have a device or a feature informing the practitioner of relevant parameters for assessing patient dose at the end of the procedure. This work presents and validates PyMCGPU-IR, a patient dose monitoring tool for interventional cardiology and radiology procedures based on MC-GPU. MC-GPU is a freely available Monte Carlo (MC) code of photon transport in a voxelized geometry which uses the computational power of commodity Graphics Processing Unit cards (GPU) to accelerate calculations. METHODOLOGIES: PyMCGPU-IR was validated against two different experimental set-ups. The first one consisted of skin dose measurements for different beam angulations on an adult Rando Alderson anthropomorphic phantom. The second consisted of organ dose measurements in three clinical procedures using the Rando Alderson phantom. RESULTS: The results obtained for the skin dose measurements show differences below 6%. For the clinical procedures the differences are within 20% for most cases. CONCLUSIONS: PyMCGPU-IR offers both, high performance and accuracy for dose assessment when compared with skin and organ dose measurements. It also allows the calculation of dose values at specific positions and organs, the dose distribution and the location of the maximum doses per organ. In addition, PyMCGPU-IR overcomes the time limitations of CPU-based MC codes.


Subject(s)
Photons , Radiology, Interventional , Adult , Humans , Monte Carlo Method , Phantoms, Imaging
16.
J Radiol Prot ; 41(4)2021 Dec 06.
Article in English | MEDLINE | ID: mdl-34670207

ABSTRACT

The exposure of the fingers is one of the major radiation protection concerns in nuclear medicine (NM). The purpose of this paper is to provide an overview of the exposure, dosimetry and protection of the extremities in NM. A wide range of reported finger doses were found in the literature. Historically, the highest finger doses are found at the fingertip in the preparation and dispensing of18F for diagnostic procedures and90Y for therapeutic procedures. Doses can be significantly reduced by following recommendations on source shielding, increasing distance and training. Additionally, important trends contributing to a lower dose to the fingers are the use of automated procedures (especially for positron emission tomography (PET)) and the use of prefilled syringes. On the other hand, the workload of PET procedures has substantially increased during the last ten years. In many cases, the accuracy of dose assessment is limited by the location of the dosimeter at the base of the finger and the maximum dose at the fingertip is underestimated (typical dose ratios between 1.4 and 7). It should also be noted that not all dosimeters are sensitive to low-energy beta particles and there is a risk for underestimation of the finger dose when the detector or its filter is too thick. While substantial information has been published on the most common procedures (using99mTc,18F and90Y), less information is available for more recent applications, such as the use of68Ga for PET imaging. Also, there is a need for continuous awareness with respect to contamination of the fingers, as this factor can contribute substantially to the finger dose.


Subject(s)
Nuclear Medicine , Occupational Exposure , Fingers , Occupational Exposure/analysis , Radiation Dosage , Tomography, X-Ray Computed
17.
Catheter Cardiovasc Interv ; 98(5): E687-E694, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34347935

ABSTRACT

OBJECTIVES: To investigate a novel suspended radiation shield (ZG), in reducing operator radiation exposure during cardiology interventions. BACKGROUND: Radiation exposure to the operator remains an occupational health hazard in the cardiac catheterization laboratory. METHODS: An anthropomorphic mannequin simulating an operator was placed near a phantom, simulating a patient. To measure the operator dose reduction, thermoluminescent detectors (TLDs) were inserted into the head and into the eye bulbs of the mannequin, while electronic dosimeters were positioned on the temple and at the level of the thyroid. Measurements were performed without and with the ZG system in place. Physician exposure was subsequently prospectively measured on the torso, on the left eye and on upper arm using the same electronic dosimeters, during clinical procedures (coronary angiography (CA) and percutaneous coronary intervention (PCI)). The physicians dose reduction was assessed by comparing operator dose when using traditional radioprotection garments (Phase 0) versus using the ZG system (Phase 1). RESULTS: Dose reductions as measured on the mannequin ranged from 66% to the head, to 100% to the torso. No dose was detected at the level of the torso and thyroid with ZG. When comparing CA and PCI procedures between Phase 0 and Phase 1, a significant difference (p < 0.001) was found for the left eye and the left wrist. Dose reduction as measured during clinical procedures for left eye/upper arm were on average 78.9%/95.6% for CA and 83.0%/93.0% for PCI, respectively (p < 0.001 for both). CONCLUSIONS: The ZG systems has a great potential to significantly reduce operator dose through the creation of a nearly zero-radiation work environment.


Subject(s)
Cardiology , Occupational Exposure , Percutaneous Coronary Intervention , Radiation Exposure , Radiation Protection , Coronary Angiography/adverse effects , Humans , Occupational Exposure/adverse effects , Percutaneous Coronary Intervention/adverse effects , Radiation Dosage , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Radiography, Interventional/adverse effects , Risk Factors , Treatment Outcome
18.
Phys Med ; 86: 44-56, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34052671

ABSTRACT

The use of patient contact-shielding has become a topic of intensive scientific debate. While it has been common practice during the last decades, some studies have questioned the efficiency of using such shielding while others have highlighted the inconsistencies in its application. The objective of this work is to review current recommendations and legislative documents on the use of out-of-field shielding in X-ray imaging, including those from national authorities and from international and national organisations and professional bodies. The review, performed within the framework of the activities of EURADOS Working Group 12, covers available recommendations on use of contact shielding in adult, pregnant and paediatric patients in general radiography, fluoroscopy, computed tomography, mammography and dental radiology. It includes a comprehensive search of 83 documents from 32 countries and 6 international organisations over the last 39 years. In general, using shielding is recommended only under two conditions: if it does not compromise the diagnostic task and the performance of the procedure and/or if it reassures the patient and comforters that they are appropriately protected against potentially harmful effects of radiation. There are very few specific regulatory requirements to use shielding in a particular imaging modality, although they may consider use of shielding either as part of good radiological practice or as requirements for availability of protective or ancillary tools, without further specification of their use. There is a wide variety of positions among documents that recommend out-of-field shielding, those that do not recommend it and those that are not specific. Therefore, evidence-based consensus is still needed to ensure best and consistent practice.


Subject(s)
Radiology , Adult , Child , Fluoroscopy , Humans , Radiography , Tomography, X-Ray Computed , X-Rays
19.
Radiat Res ; 196(1): 74-99, 2021 07 01.
Article in English | MEDLINE | ID: mdl-33914893

ABSTRACT

Within the European Epidemiological Study to Quantify Risks for Paediatric Computerized Tomography (EPI-CT study), a cohort was assembled comprising nearly one million children, adolescents and young adults who received over 1.4 million computed tomography (CT) examinations before 22 years of age in nine European countries from the late 1970s to 2014. Here we describe the methods used for, and the results of, organ dose estimations from CT scanning for the EPI-CT cohort members. Data on CT machine settings were obtained from national surveys, questionnaire data, and the Digital Imaging and Communications in Medicine (DICOM) headers of 437,249 individual CT scans. Exposure characteristics were reconstructed for patients within specific age groups who received scans of the same body region, based on categories of machines with common technology used over the time period in each of the 276 participating hospitals. A carefully designed method for assessing uncertainty combined with the National Cancer Institute Dosimetry System for CT (NCICT, a CT organ dose calculator), was employed to estimate absorbed dose to individual organs for each CT scan received. The two-dimensional Monte Carlo sampling method, which maintains a separation of shared and unshared error, allowed us to characterize uncertainty both on individual doses as well as for the entire cohort dose distribution. Provided here are summaries of estimated doses from CT imaging per scan and per examination, as well as the overall distribution of estimated doses in the cohort. Doses are provided for five selected tissues (active bone marrow, brain, eye lens, thyroid and female breasts), by body region (i.e., head, chest, abdomen/pelvis), patient age, and time period (1977-1990, 1991-2000, 2001-2014). Relatively high doses were received by the brain from head CTs in the early 1990s, with individual mean doses (mean of 200 simulated values) of up to 66 mGy per scan. Optimization strategies implemented since the late 1990s have resulted in an overall decrease in doses over time, especially at young ages. In chest CTs, active bone marrow doses dropped from over 15 mGy prior to 1991 to approximately 5 mGy per scan after 2001. Our findings illustrate patterns of age-specific doses and their temporal changes, and provide suitable dose estimates for radiation-induced risk estimation in epidemiological studies.


Subject(s)
Radiation Dosage , Tomography, X-Ray Computed , Adolescent , Child , Child, Preschool , Cohort Studies , Europe/epidemiology , Female , Humans , Infant , Infant, Newborn , Male , Phantoms, Imaging
20.
Phys Med ; 82: 279-294, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33706118

ABSTRACT

PURPOSE: Online and offline software products can estimate the maximum skin dose (MSD) delivered to the patient during interventional cardiology procedures. The capabilities and accuracy of several skin dose mapping (SDM) software products were assessed on X-ray systems from the main manufacturers following a common protocol. METHODS: Skin dose was measured on four X-ray systems following a protocol composed of nine fundamental irradiation set-ups and three set-ups simulating short, clinical procedures. Dosimeters/multimeters with semiconductor-based detectors, radiochromic films and thermoluminescent dosimeters were used. Results were compared with up to eight of 10 SDM products, depending on their compatibility. RESULTS: The MSD estimates generally agreed with the measurements within ± 40% for fundamental irradiation set-ups and simulated procedures. Only three SDM products provided estimates within ± 40% for all tested configurations on at least one compatible X-ray system. No SDM product provided estimates within ± 40% for all combinations of configurations and compatible systems. The accuracy of the MSD estimate for lateral irradiations was variable and could be poor (up to 66% underestimation). Most SDM products produced maps which qualitatively represented the dimensions, the shape and the relative position of the MSD region. Some products, however, missed the MSD region when situated at the intersection of multiple fields, which is of radiation protection concern. CONCLUSIONS: It is very challenging to establish a common protocol for quality control (QC) and acceptance testing because not all information necessary for accurate MSD calculation is available or standardised in the radiation dose structured reports (RDSRs).


Subject(s)
Cardiology , Radiation Protection , Fluoroscopy , Humans , Radiation Dosage , Radiation Dosimeters , Skin , Software