1.
Life Sci Space Res (Amst) ; 39: 106-118, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37945083

ABSTRACT

The dosimeter Liulin-MO for measuring the radiation environment onboard the ExoMars Trace Gas Orbiter (TGO) is a module of the Fine Resolution Epithermal Neutron Detector (FREND). Here we present results from measurements of the charged particle fluxes, dose rates and estimation of dose equivalent rates at ExoMars TGO Mars science orbit, provided by Liulin-MO from May 2018 to June 2022. The period of measurements covers the declining and minimum phases of the solar activity in 24th solar cycle and the rising phase of the 25th cycle. Compared are the radiation values of the galactic cosmic rays (GCR) obtained during the different phases of the solar activity. The highest values of the dose rate and flux from GCR are registered from March to August 2020. At the minimum of 24th and transition to 25th solar cycle the dose rate from GCR is 15.9 ± 1.6 µGy h-1, particle flux is 3.3 ± 0.17 cm-2s-1, dose equivalent rate is 72.3 ± 14.4 µSv h-1. Since September 2020 the dose rate and flux of GCR decrease. Particular attention is drawn to the observation of the solar energetic particle (SEP) events in July, September and October 2021, February and March 2022 as well as their effects on the radiation environment on TGO during the corresponding periods. The SEP event during15-19 February 2022 is the most powerful event observed in our data. The SEP dose during this event is 13.8 ± 1.4 mGy (in Si), the SEP dose equivalent is 21.9 ± 4.4 mSv. SEP events recorded in Mars orbit are related to coronal mass ejections (CME) observed by SOHO and STEREO A coronagraphs. Compared are the time profiles of the count rates measured by Liulin-MO, the neutron detectors of FREND and neutron detectors of the High Energy Neutron Detector (HEND) aboard Mars Odyssey during 15-19 February 2022 event. The data obtained is important for the knowledge of the radiation environment around Mars, regarding future manned and robotic flights to the planet. The data for SEP events in Mars orbit during July 2021-March 2022 contribute to the details on the solar activity at a time when Mars is on the opposite side of the Sun from Earth.


Subject(s)
Cosmic Radiation , Radiation Monitoring , Space Flight , Solar Activity , Orbit , Radiation Monitoring/methods
2.
Life Sci Space Res (Amst) ; 39: 43-51, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37945088

ABSTRACT

The data from two Bulgarian-German instruments with the basic name "Radiation Risk Radiometer-Dosimeter" (R3D) are discussed. The R3DR instrument worked inside the ESA EXPOSE-R facility (2009-2010), while R3DR2 worked inside the ESA EXPOSE-R2 facility (2014-2016). Both were outside the Russian Zvezda module on the International Space Station (ISS). The data from both instruments were used for calculation of the neutron dose equivalent rate. Similar data, obtained by the Russian "BTNNEUTRON" instrument on the ISS are used to benchmark the R3DR/R2 neutron dose equivalent rate. The analisys reveals that the "BTNNEUTRON" and R3DR/R2 values are comparable both in the equatorial and in the South Atlantic Anomaly (SAA) regions. The R3DR/R2 values are smaller than the "BTNNEUTRON" values in the high latitude regions. The comparison with the Monte Carlo simulations of the secondary galactic cosmic rays (GCR) neutron ambient dose equivalent rates (El-Jaby and Richardson, 2015, 2016) also shows a good coincidence with the R3DR/R2 spectrometer data obtained in the equatorial and high latitude regions.


Subject(s)
Cosmic Radiation , Radiation Monitoring , Space Flight , Spacecraft , Radiation Dosage , Radiometry , Neutrons
3.
Life Sci Space Res (Amst) ; 26: 114-124, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32718677

ABSTRACT

The paper presents the solar modulation of the long-term galactic cosmic rays (GCR) flux and dose rates variations, observed during 14 space experiments by 10 Bulgarian build Liulin-type spectrometers (LTS) (Dachev et al., 2015a). They worked in near Earth space and in the interplanetary radiation environment between January 1991 and January 2019. Data were collected by LTS in the low Earth orbit (LEO) in the L range between 4 and 6.2 or outside the magnetosphere. The major advantage of the data sets are that they are obtained by the electronically identical LTS. The Liulin measurements of about monthly averaged flux and dose rate data are compared with the monthly values of the modulation parameter, reconstructed from the ground based cosmic ray data (Usoskin et al., 2017). A good correlation between the two data sets is observed. The most important achievement of the paper is that for the first time a proof of the solar modulation of the long-term variations of the monthly averaged dose rates is obtained. These long-term experimentally obtained dose rate data could be used for modeling of the GCR space radiation risks to humans in the near Earth radiation environment. Parallel to the long-term dose rate varitions, the monthly averaged flux variations are also presented.


Subject(s)
Cosmic Radiation , Radiation Dosage , Radiation Monitoring , Solar Activity , Spacecraft , Extraterrestrial Environment , Space Flight
4.
Astrobiology ; 12(5): 403-11, 2012 May.
Article in English | MEDLINE | ID: mdl-22680687

ABSTRACT

The aim of this paper is to present the time profile of cosmic radiation exposure obtained by the Radiation Risk Radiometer-Dosimeter during the EXPOSE-E mission in the European Technology Exposure Facility on the International Space Station's Columbus module. Another aim is to make the obtained results available to other EXPOSE-E teams for use in their data analysis. Radiation Risk Radiometer-Dosimeter is a low-mass and small-dimension automatic device that measures solar radiation in four channels and cosmic ionizing radiation as well. The main results of the present study include the following: (1) three different radiation sources were detected and quantified-galactic cosmic rays (GCR), energetic protons from the South Atlantic Anomaly (SAA) region of the inner radiation belt, and energetic electrons from the outer radiation belt (ORB); (2) the highest daily averaged absorbed dose rate of 426 µGy d(-1) came from SAA protons; (3) GCR delivered a much smaller daily absorbed dose rate of 91.1 µGy d(-1), and the ORB source delivered only 8.6 µGy d(-1). The analysis of the UV and temperature data is a subject of another article (Schuster et al., 2012 ).


Subject(s)
Cosmic Radiation , Radiation Monitoring/instrumentation , Spacecraft , Protons , Radiation Monitoring/methods , Radiometry/instrumentation , Space Flight
5.
Astrobiology ; 12(5): 393-402, 2012 May.
Article in English | MEDLINE | ID: mdl-22680686

ABSTRACT

Radiation Risk Radiometer-Dosimeter E (R3DE) served as a device for measuring ionizing and non-ionizing radiation as well as cosmic radiation reaching biological samples located on the EXPOSE platform EXPOSE-E. The duration of the mission was almost 1.5 years (2008-2009). With four channels, R3DE detected the wavelength ranges of photosynthetically active radiation (PAR, 400-700 nm), UVA (315-400 nm), UVB (280-315 nm), and UVC (<280 nm). In addition, the temperature was recorded. Cosmic ionizing radiation was assessed with a 256-channel spectrometer dosimeter (see separate report in this issue). The light and UV sensors of the device were calibrated with spectral measurement data obtained by the Solar Radiation and Climate Experiment (SORCE) satellite as standard. The data were corrected with respect to the cosine error of the diodes. Measurement frequency was 0.1 Hz. Due to errors in data transmission or temporary termination of EXPOSE power, not all data could be acquired. Radiation was not constant during the mission. At regular intervals of about 2 months, low or almost no radiation was encountered. The radiation dose during the mission was 1823.98 MJ m(-2) for PAR, 269.03 MJ m(-2) for UVA, 45.73 MJ m(-2) for UVB, or 18.28 MJ m(-2) for UVC. Registered sunshine duration during the mission was about 152 days (about 27% of mission time).The surface of EXPOSE was most likely turned away from the Sun for considerably longer. R3DE played a crucial role on EXPOSE-EuTEF (EuTEF, European Technology Exposure Facility), because evaluation of the astrobiology experiments depended on reliability of the data collected by the device. Observed effects in the samples were weighted by radiation doses measured by R3DE.


Subject(s)
Radiometry , Solar Energy , Spacecraft , Exobiology , Radiation, Ionizing , Ultraviolet Rays
6.
Radiat Meas ; 35(2): 127-34, 2002 Apr.
Article in English | MEDLINE | ID: mdl-11841107

ABSTRACT

We are developing a portable dosimeter (Liulin-4J) based on a silicon semiconductor detector for use in measuring the absorbed dose from primary or secondary cosmic rays to astronauts and airplane crews. The dosimeter can measure not only the flux and dose rate, but also the deposited energy spectrum for silicon in per unit time. In order to calibrate the dosimeter, we have carried out exposures at the NIRS cyclotron and HIMAC heavy ion synchrotron facilities. We obtained a detector response function for using in measuring energy deposition and LET.


Subject(s)
Cosmic Radiation , Heavy Ions , Protons , Radiation Monitoring/instrumentation , Space Flight/instrumentation , Astronauts , Calibration , Cyclotrons , Humans , Radiation Protection , Radiometry , Semiconductors , Silicon , Synchrotrons