Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cornea ; 38(11): 1456-1464, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31490272

ABSTRACT

PURPOSE: To develop semi-automated application software that quickly analyzes infrared meibography images taken with the CSO Sirius Topographer (CSO, Italy) and to compare them to the manual analysis system on the device (Phoenix software platform). METHODS: A total of 52 meibography images verified as high quality were used and analyzed through manual and semi-automated meibomian gland (MG) detector software in this study. For the manual method, an experienced researcher circumscribed the MGs by putting dots around grape-like clusters in a predetermined rectangular area, and Phoenix software measured the MG loss area by percentage, which took around 10 to 15 minutes. MG loss was graded from 1 (<25%) to 4 (severe >75%). For the semi-automated method, 2 blind physicians (I and II) determined the area to be masked by putting 5 to 6 dots on the raw images and measured the MG loss area using the newly developed semi-automated MG detector application software in less than 1 minute. Semi-automated measurements were repeated 3 times on different days, and the results were evaluated using paired-sample t test, Bland-Altman, and kappa κ analysis. RESULTS: The mean MG loss area was 37.24% with the manual analysis and 40.09%, 37.89%, and 40.08% in the first, second, and third runs with the semi-automated analysis (P < 0.05). Manual analysis scores showed a remarkable correlation with the semi-automated analysis performed by 2 operators (r = 0.950 and r = 0.959, respectively) (P < 0.001). According to Bland-Altman analysis, the 95% limits of agreement between manual analysis and semi-automated analysis by operator I were between -10.69% and 5% [concordance correlation coefficient (CCC) = 0.912] and between -9.97% and 4.3% (CCC = 0.923) for operator II. The limit of interoperator agreement in semi-automated analysis was between -4.89% and 4.92% (CCC = 0.973). There was good to very good agreement in grading between manual and semi-automated analysis results (κ 0.76-0.84) and very good interoperator agreement with semi-automated software (κ 0.91) (P < 0.001). CONCLUSIONS: For the manual analysis of meibography images, around one hundred dots have to be put around grape-like clusters to determine the MGs, which makes the process too long and prone to errors. The newly developed semi-automated software is a highly reproducible, practical, and faster method to analyze infrared meibography images with excellent correlation with the manual analysis.


Subject(s)
Algorithms , Diagnostic Techniques, Ophthalmological , Infrared Rays , Meibomian Gland Dysfunction/diagnosis , Meibomian Glands/diagnostic imaging , Software , Adult , Aged , Female , Humans , Male , Middle Aged , Reproducibility of Results , Young Adult
2.
PLoS One ; 14(1): e0210954, 2019.
Article in English | MEDLINE | ID: mdl-30689644

ABSTRACT

Understanding expression levels of proteins and their interactions is a key factor to diagnose and explain the Down syndrome which can be considered as the most prevalent reason of intellectual disability in human beings. In the previous studies, the expression levels of 77 proteins obtained from normal genotype control mice and from trisomic Ts65Dn mice have been analyzed after training in contextual fear conditioning with and without injection of the memantine drug using statistical methods and machine learning techniques. Recent studies have also pointed out that there may be a linkage between the Down syndrome and the immune system. Thus, the research presented in this paper aim at in silico identification of proteins which are significant to the learning process and the immune system and to derive the most accurate model for classification of mice. In this paper, the features are selected by implementing forward feature selection method after preprocessing step of the dataset. Later, deep neural network, gradient boosting tree, support vector machine and random forest classification methods are implemented to identify the accuracy. It is observed that the selected feature subsets not only yield higher accuracy classification results but also are composed of protein responses which are important for the learning and memory process and the immune system.


Subject(s)
Down Syndrome/genetics , Down Syndrome/psychology , Nerve Tissue Proteins/physiology , Animals , Bayes Theorem , Computer Simulation , Disease Models, Animal , Down Syndrome/immunology , Gene Expression , Humans , Immune System Phenomena/genetics , Immune System Phenomena/physiology , Learning/physiology , Memantine/administration & dosage , Mice , Nerve Tissue Proteins/genetics , Nerve Tissue Proteins/immunology , Neural Networks, Computer , Support Vector Machine , Trisomy
SELECTION OF CITATIONS
SEARCH DETAIL
...