EuroIntervention ; 19(7): 580-588, 2023 Sep 18.
Article in English | MEDLINE | ID: mdl-37565470

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in non-calcified aortic regurgitation (NCAR) is an off-label procedure. The balloon-expandable Myval includes extra-large sizes (30.5 mm and 32 mm) of interest in this setting. AIMS: We aimed to evaluate the safety and feasibility of Myval in NCAR. METHODS: This was an international, multicentre, observational study that enrolled all consecutive patients with symptomatic severe NCAR undergoing TAVR with the Myval device. The images were centrally analysed. RESULTS: A total of 113 patients were recruited, 64.6% were men, the mean age was 78.4±7.5 years, and the Society of Thoracic Surgeons score was 2.7±1.7%. Aortic root dilatation was present in 59.3% of patients, 7.1% were bicuspid, and the mean annular area was 638.6±106.0 mm2. The annular area was beyond the recommended range for extra-large sizes in 2.6% of cases, and additional volume was added in 92% (median 4 cc, up to 9 cc). The extra-large sizes were used in 95 patients (84.1%), and the mean oversizing was 17.9±11.0%. The technical success rate was 94.7%; the rate of residual ≥moderate aortic regurgitation was 8.9%, and the pacemaker rate was 22.2%. There were no cases of annular rupture, cardiac tamponade, or aortic dissection, but in 4 patients (3.5%) valve embolisation occurred (1 antegrade and 3 ventricular), all in cases with a tapered left ventricle outflow tract (p=0.007). Thirty-day and 1-year mortality were 5.3% and 9.7%, respectively. Technical success was associated with better survival (97.1% vs 72.7%; p=0.012), and valve embolisation was the main determinant of mortality (p=0.047). CONCLUSIONS: Myval is a feasible and safe option for selected non-operable patients with NCAR and demonstrated good midterm outcomes and lack of impact of oversizing on device durability.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Male , Humans , Aged , Aged, 80 and over , Female , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Treatment Outcome , Prosthesis Design
2.
Rev. colomb. cardiol ; 29(supl.4): 38-41, dic. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1423810

ABSTRACT

Abstract We present the first case in Colombia of tricuspid endovascular valve in valve for failed bioprosthesis in a 40 years old patient with very high operative risk with great results, proposing kissing balloon annulus cracking technique as a practical solution for the colombian specialists.


Resumen Se presenta el primer caso en Colombia de un reemplazo percutáneo tipo válvula en válvula por falla de bioprótesis tricúspide en un paciente de 40 años con un muy alto riesgo quirúrgico, con excelentes resultados, proponiendo la técnica kissing balloon de fractura anular como una solución práctica para los especialistas colombianos.

3.
Rev. colomb. cardiol ; 29(5): 593-596, jul.-set. 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1423786

ABSTRACT

Abstract We present the first case in Colombia of tricuspid endovascular valve in valve for failed bioprosthesis in a 40-year-old patient with very high operative risk with great results, proposing kissing balloon annulus cracking technique as a practical solution for the Colombian specialists.


Resumen Presentamos el primer caso en Colombia de valve in valve tricúspideo para una bioprótesis deteriorada en una paciente de 40 años con muy alto riesgo quirúrgico con muy buenos resultados, y se propone la técnica de kissing balloon para ruptura anular como una solución practica para los especialistas en Colombia.

4.
Int J Cardiol ; 321: 48-53, 2020 Dec 15.
Article in English | MEDLINE | ID: mdl-32810542

ABSTRACT

BACKGROUND: RENASCENT is a prospective, multi-center first-in-human clinical study to evaluate the clinical performance of the novel sirolimus-eluting 150-µm strut thickness FORTITUDE® BRS for percutaneous coronary intervention of single de novo coronary lesions. METHODS: FORTITUDE® BRS was tested in a prospective study in Italy and Colombia. Study objectives were in-scaffold angiographic late lumen loss (LLL) measured by quantitative coronary angiography and target vessel failure (TVF) defined as the composite rate of cardiac death, target vessel myocardial infarction or ischemia driven target lesion revascularization (TLR) at 9- and 24-months with clinical results up to 36-months. RESULTS: A total of 63 patients were enrolled. All patients underwent lesion pre-dilatation and 22 patients (34.9%) underwent post-dilatation. Clinical device and procedural success was 98.4% (62/63 patients) and 96.8% (61/63 patients) respectively. At 9-months, TVF occurred in 3/61 (4.9%) of the patients including 2 peri-procedural MI and one ischemia-driven TLR. Between 9- to 24-months, ischemia-driven TLR occurred in 3 additional patients (4.9%) including 1 patient who presented with very late ST after stopping all medications. There were no further TVF between 24- and 36-months. CONCLUSIONS: In this multi-center prospective study, the FORTITUDE® BRS was shown to be safe and effective in the treatment of single coronary lesions with low levels of TVF and LLL at 9- and 24-months. It was shown to be clinically safe upto 36-months follow-up.


Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Coronary Restenosis , Drug-Eluting Stents , Percutaneous Coronary Intervention , Absorbable Implants , Cardiovascular Agents/therapeutic use , Colombia , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/drug therapy , Coronary Artery Disease/surgery , Coronary Restenosis/drug therapy , Humans , Italy , Molecular Weight , Prospective Studies , Prosthesis Design , Sirolimus , Tomography, Optical Coherence , Treatment Outcome
5.
Circ Cardiovasc Interv ; 11(11): e006927, 2018 11.
Article in English | MEDLINE | ID: mdl-30571207

ABSTRACT

BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.12-2.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.84-2.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.75-1.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.68-1.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up ( P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB ( P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.


Subject(s)
Aortic Valve/surgery , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial , Heart Valve Diseases/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Brazil/epidemiology , Bundle-Branch Block/diagnosis , Bundle-Branch Block/mortality , Bundle-Branch Block/physiopathology , Canada/epidemiology , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/mortality , Echocardiography , Electrocardiography , Europe/epidemiology , Female , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/mortality , Heart Valve Diseases/physiopathology , Humans , Male , Pacemaker, Artificial , Postoperative Complications/mortality , Postoperative Complications/therapy , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
6.
Circ., cariovasc. interv. (Print) ; 11(11): 006927, Nov. 2018. tab, graf
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1223598

ABSTRACT

BACKGROUND: The impact of preexisting left bundle branch block (LBBB) in transcatheter aortic valve replacement (TAVR) recipients is unknown. The aim of this study was to determine the impact of preexisting LBBB on clinical outcomes after TAVR. METHODS AND RESULTS: This multicenter study evaluated 3404 TAVR candidates according to the presence or absence of LBBB on baseline ECG. TAVR complications and causes of death were defined according to Valve Academic Research Consortium-2 definitions. Follow-up outpatient visits or telephone interviews were conducted at 30 days, 12 months, and yearly thereafter. Echocardiography examinations were performed at baseline, at hospital discharge, and at 1-year follow-up. Preexisting LBBB was present in 398 patients (11.7%) and was associated with an increased risk of permanent pacemaker implantation (PPI; 21.1% versus 14.8%; adjusted odds ratio, 1.51; 95% CI, 1.12­2.04) but not death (7.3% versus 5.5%; adjusted odds ratio, 1.33; 95% CI, 0.84­2.12) at 30 days. At a mean follow-up of 22±21 months, there were no differences between patients with and without preexisting LBBB in overall mortality (adjusted hazard ratio, 0.94; 95% CI, 0.75­1.18) and cardiovascular mortality (adjusted hazard ratio, 0.90; 95% CI, 0.68­1.21). In a subanalysis of 2421 patients without PPI at 30 days and with complete follow-up about the PPI, preexisting LBBB was not associated with an increased risk of PPI or sudden cardiac death. Patients with preexisting LBBB had a lower left ventricular ejection fraction (LVEF) at baseline and at 1-year follow-up (P <0.001 for both), but those with low LVEF exhibited a similar increase in LVEF over time after TAVR compared with patients with no preexisting LBBB (P=0.327). CONCLUSIONS: Preexisting LBBB significantly increased the risk of early (but not late) PPI after TAVR, without any significant effect on overall mortality or cardiovascular mortality. Preexisting LBBB was associated with lower LVEF pre-TAVR but did not prevent an increase in LVEF post-TAVR similar to patients without LBBB.


Subject(s)
Bundle-Branch Block , Transcatheter Aortic Valve Replacement/statistics & numerical data
7.
Circ Cardiovasc Interv ; 11(9): e007038, 2018 09.
Article in English | MEDLINE | ID: mdl-30354588

ABSTRACT

BACKGROUND: Data on long-term outcomes after valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) are scarce. The objective of this study was to determine the long-term clinical outcomes and structural valve degeneration (SVD) over time in patients undergoing ViV-TAVR. METHODS AND RESULTS: Consecutive patients undergoing ViV-TAVR in 9 centers between 2009 and 2015 were included. Patients were followed yearly, and clinical and echocardiography data were collected prospectively. SVD was defined as subclinical (increase >10 mm Hg in mean transvalvular gradient+decrease >0.3 cm2 in valve area or new-onset mild or moderate aortic regurgitation) and clinically relevant (increase >20 mm Hg in mean transvalvular gradient+decrease >0.6 cm2 in valve area or new-onset moderate-to-severe aortic regurgitation). A total of 116 patients (mean age, 76±11 years; 64.7% male; mean Society of Thoracic Surgeons score, 8.0±5.1%) were included. Balloon- and self-expandable valves were used in 47.9% and 52.1% of patients, respectively, and 30-day mortality was 6.9%. At a median follow-up of 3 years (range, 2-7 years), 30 patients (25.9%) had died, 20 of them (17.2%) from cardiovascular causes. Average mean transvalvular gradients remained stable up to 5-year follow-up ( P=0.92), but clinically relevant SVD occurred in 3/99 patients (3.0%), and 15/99 patients (15.1%) had subclinical SVD. One patient with SVD had redo ViV-TAVR. CONCLUSIONS: About one-fourth of ViV-TAVR recipients had died after a median follow-up of 3 years. Overall valve hemodynamics remained stable over time and clinically relevant SVD was infrequent, but 1 out of 10 patients exhibited some degree of SVD.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Echocardiography, Doppler, Color , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Hemodynamics , Humans , Male , Prosthesis Design , Prosthesis Failure , Recovery of Function , Reoperation , Retrospective Studies , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
8.
JACC Cardiovasc Interv ; 11(17): 1669-1679, 2018 09 10.
Article in English | MEDLINE | ID: mdl-30190058

ABSTRACT

OBJECTIVES: The authors aimed to determine the procedural learning curve and minimum annual institutional volumes associated with optimum clinical outcomes for transcatheter aortic valve replacement (TAVR). BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a complex procedure requiring significant training and experience for successful outcome. Despite increasing use of TAVR across institutions, limited information is available for its learning curve characteristics and minimum annual volumes required to optimize clinical outcomes. METHODS: The study collected data for patients at 16 centers participating in the international TAVR registry since initiation of the respective TAVR program. All cases were chronologically ordered into initial (1 to 75), early (76 to 150), intermediate (151 to 225), high (226 to 300), and very high (>300) experience operators for TAVR learning curve characterization. In addition, participating institutions were stratified by annual TAVR case volume into low-volume (<50), moderate-volume (50 to 100), and high-volume (>100) groups for comparative analysis. Procedural and 30-day clinical outcomes were collected and multivariate regression analysis performed for 30-day mortality and the early safety endpoint. RESULTS: A total of 3,403 patients comprised the study population. On multivariate analysis, all-cause mortality was significantly higher for initial (odds ratio [OR]: 3.83; 95% confidence interval [CI]: 1.93 to 7.60), early (OR: 2.41; 95% CI: 1.51 to 5.03), and intermediate (OR: 2.53; 95% CI: 1.19 to 5.40) experience groups compared with the very high experience operators. In addition, the early safety endpoint was significantly worse for all experience groups compared with the very high experience operators. Low annual volume (<50) TAVR institutions had significantly higher all-cause 30-day mortality (OR: 2.70; 95% CI: 1.44 to 5.07) and worse early safety endpoint (OR: 1.60; 95% CI: 1.17 to 2.17) compared with the moderate- and high-volume groups. There was no difference in patient outcomes between intermediate and high annual volume groups. CONCLUSIONS: TAVR procedures display important learning curve characteristics with both greater procedural safety and a lower mortality when performed by experienced operators. In addition, TAVR performed at low annual volume (<50 procedures) institutions is associated with decreased procedural safety and higher patient mortality. These findings have important implications for operator training and patient care at centers performing TAVR.


Subject(s)
Clinical Competence/standards , Hospitals, High-Volume/standards , Hospitals, Low-Volume/standards , Learning Curve , Outcome and Process Assessment, Health Care/standards , Surgeons/standards , Transcatheter Aortic Valve Replacement/standards , Aged , Aged, 80 and over , Female , Humans , Male , Patient Safety/standards , Postoperative Complications/epidemiology , Registries , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Workload/standards
9.
JACC cardiovasc. interv ; 11(17): 1669-1679, Sept. 2018. graf, tab
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1247793

ABSTRACT

OBJECTIVES: The authors aimed to determine the procedural learning curve and minimum annual institutional volumes associated with optimum clinical outcomes for transcatheter aortic valve replacement (TAVR).BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a complex procedure requiring significant training and experience for successful outcome. Despite increasing use of TAVR across institutions, limited information is available for its learning curve characteristics and minimum annual volumes required to optimize clinical outcomes. METHODS: The study collected data for patients at 16 centers participating in the international TAVR registry since initiation of the respective TAVR program. All cases were chronologically ordered into initial (1 to 75), early (76 to 150), intermediate (151 to 225), high (226 to 300), and very high (>300) experience operators for TAVR learning curve characterization. In addition, participating institutions were stratified by annual TAVR case volume into low-volume (<50), moderate-volume (50 to 100), and high-volume (>100) groups for comparative analysis. Procedural and 30-day clinical outcomes were collected and multivariate regression analysis performed for 30-day mortality and the early safety endpoint. RESULTS: A total of 3,403 patients comprised the study population. On multivariate analysis, all-cause mortality was significantly higher for initial (odds ratio [OR]: 3.83; 95% confidence interval [CI]: 1.93 to 7.60), early (OR: 2.41; 95%CI: 1.51 to 5.03), and intermediate (OR: 2.53; 95% CI: 1.19 to 5.40) experience groups compared with the very high experience operators. In addition, the early safety endpoint was significantly worse for all experience groups compared with the very high experience operators. Low annual volume (<50) TAVR institutions had significantly higher all-cause30-day mortality (OR: 2.70; 95% CI: 1.44 to 5.07) and worse early safety endpoint (OR: 1.60; 95% CI: 1.17 to 2.17) compared with the moderate- and high-volume groups. There was no difference in patient outcomes between intermediate and high annual volume groups. CONCLUSIONS: TAVR procedures display important learning curve characteristics with both greater procedural safety and a lower mortality when performed by experienced operators. In addition, TAVR performed at low annual volume (<50 procedures) institutions is associated with decreased procedural safety and higher patient mortality. These findings have important implications for operator training and patient care at centers performing TAVR.


Subject(s)
Humans , Female , Aged, 80 and over , Learning Curve , Transcatheter Aortic Valve Replacement/adverse effects
10.
Heart ; 104(10): 814-820, 2018 05.
Article in English | MEDLINE | ID: mdl-29440192

ABSTRACT

OBJECTIVE: To evaluate the changes in transvalvular gradients and the incidence of valve haemodynamic deterioration (VHD) following transcatheter aortic valve replacement (TAVR), according to use of anticoagulation therapy. METHODS AND RESULTS: This multicentre study included 2466 patients (46% men; mean age 81±7 years) who underwent TAVR with echocardiography performed at 12-month follow-up. Anticoagulation therapy was used in 707 patients (28.7%) following TAVR (AC group). A total of 663 patients received vitamin K antagonists, and 44 patients received direct oral anticoagulants. A propensity score matching analysis was performed to adjust for intergroup (AC vs non-AC post-TAVR) differences. A total of 622 patients per group were included in the propensity-matched analysis. VHD was defined as a ≥10 mm Hg increase in the mean transprosthetic gradient at follow-up (vs hospital discharge). The mean clinical follow-up was 29±18 months. The mean transvalvular gradient significantly increased at follow-up in the non-AC group within the global cohort (P=0.003), whereas it remained stable over time in the AC group (P=0.323). The incidence of VHD was significantly lower in the AC group (0.6%) compared with the non-AC group (3.7%, P<0.001), and these significant differences remained within the propensity-matched populations (0.6% vs 3.9% in the AC and non-AC groups, respectively, P<0.001). The occurrence of VHD did not associate with an increased risk of all-cause death (P=0.468), cardiovascular death (P=0.539) or stroke (P=0.170) at follow-up. CONCLUSIONS: The lack of anticoagulation therapy post-TAVR was associated with significant increments in transvalvular gradients and a greater risk of VHD. VHD was subclinical in most cases and did not associate with major adverse clinical events. Future randomised trials are needed to determine if systematic anticoagulation therapy post-TAVR would reduce the incidence of VHD.


Subject(s)
Aortic Valve Stenosis/surgery , Fibrinolytic Agents , Hemodynamics/drug effects , Postoperative Complications , Thrombosis , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Echocardiography/methods , Europe/epidemiology , Female , Fibrinolytic Agents/administration & dosage , Fibrinolytic Agents/adverse effects , Follow-Up Studies , Heart Valve Prosthesis/adverse effects , Humans , Kaplan-Meier Estimate , Male , Postoperative Complications/diagnosis , Postoperative Complications/prevention & control , Thrombosis/etiology , Thrombosis/prevention & control , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
11.
Int J Cardiol ; 245: 222-227, 2017 Oct 15.
Article in English | MEDLINE | ID: mdl-28760395

ABSTRACT

BACKGROUND: Despite rapidly increasing use of TAVR across institutions, limited data is available for the effect of procedural experience on TAVR outcomes. We investigate the relationship between institutional experience and TAVR outcomes. METHODS: 1953 patients undergoing TAVR at 8 international sites were grouped into chronological quantiles (Q) to assess temporal changes on procedural and clinical outcomes and multivariate logistic regression performed to determine predictors of device success, early safety and all-cause mortality. RESULTS: The mean age of patients was 81±7years and 991 (51%) were female. The quantiles comprised of first 62 cases for Q1, 63-133 for Q2, 134 to 242 for Q3 and 243 to 476 for Q4. Device success increased from Q1 to Q4 (78% vs 89%, p<0.001) with significant improvement in the early safety endpoint (19% vs 10%, p<0.001). All cause mortality reduced by half in Q4 compared to Q1 (8% vs 4%, p=0.01) and rates of major vascular complications, major bleeding and valve embolization decreased with increasing experience. The multivariate analysis identified TAVR in Q3 and Q4 to be independently associated with higher device success and lower risk of complications. TAVR in Q4 was independently associated with lower mortality (OR 0.36 95% CI 0.19-0.70, p=0.002). CONCLUSIONS: Greater institutional experience with TAVR procedures improves device success and clinical outcomes. An experience of >242 cases is independently associated with lower mortality. These findings have important implications for defining minimum volume criteria for institutions and training standards for TAVR procedure.


Subject(s)
Internationality , Postoperative Complications/mortality , Registries , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/trends , Aged , Aged, 80 and over , Female , Humans , Male , Mortality/trends , Postoperative Complications/diagnostic imaging , Prospective Studies , Treatment Outcome
12.
JACC Cardiovasc Interv ; 10(15): 1564-1574, 2017 08 14.
Article in English | MEDLINE | ID: mdl-28734885

ABSTRACT

OBJECTIVES: This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. METHODS: A total of 3,527 patients (mean age 82 ± 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RESULTS: RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p = 0.024). At a mean follow-up of 20 ± 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p = 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p = 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p = 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p = 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p = 0.023). CONCLUSIONS: Pre-existing RBBB was found in 10% of TAVR recipients and was associated with poorer clinical outcomes. Patients with baseline RBBB without permanent pacemakers at hospital discharge may be at especially high risk for high-degree atrioventricular block and/or SCD during follow-up. Future studies should evaluate strategies aimed at the early detection of patients at risk for late development of high-degree atrioventricular block.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bundle-Branch Block/mortality , Death, Sudden, Cardiac/epidemiology , Transcatheter Aortic Valve Replacement/mortality , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Brazil/epidemiology , Bundle-Branch Block/diagnosis , Bundle-Branch Block/physiopathology , Canada/epidemiology , Cause of Death , Echocardiography , Electrocardiography , Europe/epidemiology , Female , Humans , Kaplan-Meier Estimate , Male , Multivariate Analysis , Proportional Hazards Models , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Open Heart ; 4(1): e000521, 2017.
Article in English | MEDLINE | ID: mdl-28674616

ABSTRACT

OBJECTIVE: To evaluate the biological effect of microengineered stent grooves (MSG) on early strut healing in humans by performing optical coherence tomography (OCT) analysis 3 weeks following the implantation. BACKGROUND: In the experimental setting, MSG accelerate endothelial cell migration and reduce neointimal proliferation compared with bare metal stent (BMS). METHODS: A total of 37 patients undergoing percutaneous coronary intervention with de novo coronary lesions were randomly assigned to either MSG (n=19) or an identical BMS controls (n=18). All patients underwent OCT imaging at 3 weeks. A total of 7959 struts were included in the final analysis. RESULTS: At 3 weeks following stent implantation, almost all struts analysed (~97%) had evidence of tissue coverage. The percentage of partially covered struts was comparable between both groups. However, the percentage of fully embedded struts was higher in the BMS group (81.22%, 49.75-95.52) compared with the MSG group (74.21%, 58.85-86.38). The stent-level analysis demonstrated reduction in neointimal formation (neointimal hyperplasia area and volume reduction of ~14% and ~19%, respectively) in the MSG versus the BMS group. In the strut-level analysis, an even greater reduction (~22% in neointimal thickness) was seen in the MSG group. Layered neointimal was present in ~6% of the OCT frames in the BMS group while it was not present in the MSG group. CONCLUSIONS: MSG induced a more homogeneous and predictable pattern of surface healing in the early stages following stent implantation. The biological effect of MSG on stent healing has the potential to improve the safety profile of current generation drug-eluting stents. CLASSIFICATIONS: BMS, OCT, clinical trials.

14.
Coron Artery Dis ; 28(2): 126-134, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27879518

ABSTRACT

AIMS: Bioresorbable polymer drug-eluting stent technologies have been considered to have the potential to enhance vascular healing by reducing polymer exposure to the vessel wall, potentially allowing the earlier discontinuation of dual antiplatelet therapy. At present, the early vascular healing response to this type of technologies is still unclear. PATIENTS AND METHODS: The TIMELESS study is a multicenter, prospective, single-arm study that enrolled real-world patients undergoing percutaneous coronary intervention. All patients underwent Synergy stent implantation, which consists of a platinum-chromium platform coated with an ultra-thin abluminal bioabsorbable poly-D,L-lactide-co-glycolide polymer-eluting everolimus. RESULTS: A total of 37 patients were included in the study. The majority of the patients underwent percutaneous coronary intervention because of acute coronary syndromes. At 3 months, angiographic follow-up showed a percentage diameter of stenosis of 8.1±7.5% and an angiographic late loss of 0.03±0.24 mm. In all analyzed struts, less than 1% of struts were definitely uncovered or covered with fibrin, 12.5% (5.0-18.5%) showed evidence of partial coverage, and the remaining (∼85%) were fully covered. No stent thrombosis was observed up to 12 months of clinical follow-up. CONCLUSION: In a real-world population, the implantation of a bioresorbable polymer drug-eluting stent resulted in almost complete strut coverage throughout the entire stent length at 3 months. The clinical implications for antiplatelet therapy and outcomes should be investigated further.


Subject(s)
Absorbable Implants , Acute Coronary Syndrome/therapy , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Coronary Stenosis/therapy , Coronary Vessels/drug effects , Drug-Eluting Stents , Everolimus/administration & dosage , Lactic Acid/chemistry , Percutaneous Coronary Intervention/instrumentation , Polyglycolic Acid/chemistry , Tomography, Optical Coherence , Wound Healing/drug effects , Acute Coronary Syndrome/diagnostic imaging , Aged , Cardiovascular Agents/adverse effects , Chromium , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Drug Therapy, Combination , Everolimus/adverse effects , Female , Humans , Male , Percutaneous Coronary Intervention/adverse effects , Platelet Aggregation Inhibitors/administration & dosage , Platinum , Polylactic Acid-Polyglycolic Acid Copolymer , Predictive Value of Tests , Prosthesis Design , Time Factors , Treatment Outcome
15.
JACC cardiovasc. interv ; 10(15): 1564-1574, 2017. tab, graf
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1064046

ABSTRACT

This study sought to assess the influence of baseline right bundle branch block (RBBB) on all-cause and cardiovascular mortality as well as sudden cardiac death (SCD) among patients undergoing transcatheter aortic valve replacement (TAVR). Few data exist regarding the late clinical impact of pre-existing RBBB in TAVR recipients. A total of 3,527 patients (mean age 82 8 years, 50.1% men) were evaluated according to the presence of RBBB on baseline electrocardiography. Intraventricular conduction abnormalities were classified according to the American Heart Association, American College of Cardiology Foundation, and Heart Rhythm Society recommendations for standardization and interpretation of the electrocardiogram. TAVR complications and causes of death were defined according to Valve Academic Research Consortium 2 definitions. RBBB was present on baseline electrocardiography in 362 patients (10.3%) and associated with higher 30-day rates of permanent pacemaker implantation (PPI) (40.1% vs. 13.5%; p < 0.001) and death (10.2% vs. 6.9%; p » 0.024). At a mean follow-up of 20 18 months, pre-existing RBBB was independently associated with all-cause mortality (hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.06 to 1.63; p » 0.014) and cardiovascular mortality (HR: 1.45; 95% CI: 1.11 to 1.89; p » 0.006) but not with SCD (HR: 0.71; 95% CI: 0.22 to 2.32; p » 0.57). Patients with pre-existing RBBB and without PPI at discharge from the index hospitalization had the highest 2-year risk for cardiovascular death (27.8%; 95% CI: 20.9% to 36.1%; log-rank p » 0.007). In a subanalysis of 1,245 patients without PPI at discharge from the index hospitalization and with complete follow-up regarding the need for PPI, pre-existing RBBB was independently associated with the composite of SCD and PPI (HR: 2.68; 95% CI: 1.16 to 6.17; p » 0.023)


Subject(s)
Bundle-Branch Block , Heart Valve Prosthesis Implantation , Death, Sudden, Cardiac
17.
JACC Cardiovasc Interv ; 9(16): 1706-17, 2016 08 22.
Article in English | MEDLINE | ID: mdl-27539691

ABSTRACT

OBJECTIVES: The study sought to examine the risk of ischemic events and bleeding episodes associated with differing antithrombotic strategies in patients undergoing transcatheter aortic valve replacement (TAVR) with concomitant atrial fibrillation (AF). BACKGROUND: Guidelines recommend antiplatelet therapy (APT) post-TAVR to reduce the risk of stroke. However, data on the efficacy and safety of this recommendation in the setting of a concomitant indication for oral anticoagulation (due to atrial fibrillation [AF]) with a vitamin K antagonist (VKA) are scarce. METHODS: A multicenter evaluation comprising 621 patients with AF undergoing TAVR was undertaken. Post-TAVR prescriptions were used to determine the antithrombotic regimen used according to the following 2 groups: monotherapy (MT) with VKA (n = 101) or multiple antithrombotic therapy (MAT) with VKA plus 1 or 2 antiplatelet agents (aspirin or clopidogrel; n = 520). Endpoint definitions were in accordance with Valve Academic Research Consortium-2 criteria. The rate of stroke, major adverse cardiovascular events (stroke, myocardial infarction, or cardiovascular death), major or life-threatening bleeding events, and death were assessed by a Cox multivariate model regression survival analysis according to the antithrombotic regime used. RESULTS: During a median follow-up of 13 months (interquartile range: 3 to 31 months) there were no differences between groups in the rate of stroke (MT: 5%, MAT: 5.2%; adjusted hazard ratio [HR]: 1.25; 95% confidence interval [CI]: 0.45 to 3.48; p = 0.67), major adverse cardiovascular events (MT: 13.9%, MAT: 16.3%; adjusted HR: 1.33; 95% CI: 0.75 to 2.36; p = 0.33), and death (MT 22.8%, MAT: 19.2%; adjusted HR: 0.93; 95% CI: 0.58 to 1.50; p = 0.76). A higher risk of major or life-threatening bleeding was found in the MAT group (MT: 14.9%, MAT: 24.4%; adjusted HR: 1.85; 95% CI: 1.05 to 3.28; p = 0.04). These results remained similar when patients receiving VKA plus only 1 antiplatelet agent (n = 463) were evaluated. CONCLUSIONS: In TAVR recipients prescribed VKA therapy for AF, concomitant antiplatelet therapy use appears not to reduce the incidence of stroke, major adverse cardiovascular events, or death, while increasing the risk of major or life-threatening bleeding.


Subject(s)
Anticoagulants/administration & dosage , Aortic Valve/surgery , Atrial Fibrillation/drug therapy , Brain Ischemia/prevention & control , Heart Valve Diseases/surgery , Platelet Aggregation Inhibitors/administration & dosage , Stroke/prevention & control , Transcatheter Aortic Valve Replacement , Warfarin/administration & dosage , Aged , Aged, 80 and over , Anticoagulants/adverse effects , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/mortality , Brain Ischemia/diagnosis , Brain Ischemia/etiology , Brain Ischemia/mortality , Canada , Chi-Square Distribution , Europe , Female , Heart Valve Diseases/complications , Heart Valve Diseases/diagnosis , Heart Valve Diseases/mortality , Hemorrhage/chemically induced , Humans , Kaplan-Meier Estimate , Male , Multivariate Analysis , Platelet Aggregation Inhibitors/adverse effects , Proportional Hazards Models , Risk Factors , Stroke/diagnosis , Stroke/etiology , Stroke/mortality , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Vitamin K/antagonists & inhibitors , Vitamin K/blood , Warfarin/adverse effects
18.
J Am Coll Cardiol ; 67(25): 2927-36, 2016 06 28.
Article in English | MEDLINE | ID: mdl-27339489

ABSTRACT

BACKGROUND: Current surgical and medical treatment options for functional mitral regurgitation (FMR) are limited and additional interventional approaches are required. OBJECTIVES: This study sought to report the safety and performance data from the feasibility study with a novel direct annuloplasty system. METHODS: Seventy-one patients with moderate to severe FMR (mean 67.7 ± 11.3 years of age, left ventricular [LV] ejection fraction 34.0 ± 8.3%), on stable medical heart failure medication were prospectively enrolled. RESULTS: Device success rate was 70.4% (n = 50 of 71). No intraprocedural death occurred. In patients receiving implants, 4 patients (8.9%) experienced cardiac tamponade. Thirty-day (n = 45) and 6-month (n = 41) rates for all-cause mortality, stroke, and myocardial infarction were 4.4%, 4.4%, and 0.0% and 12.2%, 4.9%, and 0%, respectively. At 6 months, nonurgent mitral surgery was performed in 1 patient (2.4%) and nonurgent percutaneous repair in 7 patients (17.1%). Echocardiographic core analysis after 6 months showed mitral regurgitation reduction in 50% of treated patients by a mean of 1.3 grades. Concerning mitral valve (MV) annular geometry, we found significant reduction of anterior-posterior (-0.31 ± 0.4 cm) and septal-lateral dimensions (-0.21 ± 0.3 cm), a decreased MV-tenting area (-0.57 ± 1.1 cm(2)) and increase in MV coaptation length (0.13 ± 0.2 cm). Transthoracic echocardiography indicated reverse LV remodeling with reduction of LV end-diastolic diameter (-0.20 ± 0.4 mm) and volume (-22 ± 39 ml). Treatment was associated with significant improvement in 6-min walking distances (56.5 ± 92.0 m) and improvements in New York Heart Association functional class III/IV at 6 months from 53.3% to 23.3%. CONCLUSIONS: Percutaneous direct annuloplasty is feasible and safe in high-risk FMR patients. This treatment initiates LV reverse remodeling, and provides clinical improvement during 6 months after treatment. (Mitralign Percutaneous Annuloplasty First in Man Study; NCT01852149).


Subject(s)
Mitral Valve Annuloplasty/instrumentation , Mitral Valve Insufficiency/surgery , Aged , Chronic Disease , Feasibility Studies , Female , Humans , Male , Prospective Studies , Treatment Outcome
19.
J Am Coll Cardiol ; 67(6): 644-655, 2016 Feb 16.
Article in English | MEDLINE | ID: mdl-26868689

ABSTRACT

BACKGROUND: Scarce data exist on the incidence of and factors associated with valve hemodynamic deterioration (VHD) after transcatheter aortic valve replacement (TAVR). OBJECTIVES: This study sought to determine the incidence, timing, and predictors of VHD in a large cohort of patients undergoing TAVR. METHODS: This multicenter registry included 1,521 patients (48% male; 80 ± 7 years of age) who underwent TAVR. Mean echocardiographic follow-up was 20 ± 13 months (minimum: 6 months). Echocardiographic examinations were performed at discharge, at 6 to 12 months, and yearly thereafter. Annualized changes in mean gradient (mm Hg/year) were calculated by dividing the difference between the mean gradient at last follow-up and the gradient at discharge by the time between examinations. VHD was defined as a ≥10 mm Hg increase in transprosthetic mean gradient during follow-up compared with discharge assessment. RESULTS: The overall mean annualized rate of transprosthetic gradient progression during follow-up was 0.30 ± 4.99 mm Hg/year. A total of 68 patients met criteria of VHD (incidence: 4.5% during follow-up). The absence of anticoagulation therapy at hospital discharge (p = 0.002), a valve-in-valve (TAVR in a surgical valve) procedure (p = 0.032), the use of a 23-mm valve (p = 0.016), and a greater body mass index (p = 0.001) were independent predictors of VHD. CONCLUSIONS: There was a mild but significant increase in transvalvular gradients over time after TAVR. The lack of anticoagulation therapy, a valve-in-valve procedure, a greater body mass index, and the use of a 23-mm transcatheter valve were associated with higher rates of VHD post-TAVR. Further prospective studies are required to determine whether a specific antithrombotic therapy post-TAVR may reduce the risk of VHD.


Subject(s)
Aortic Valve/physiopathology , Heart Valve Prosthesis/adverse effects , Hemodynamics/physiology , Postoperative Complications/epidemiology , Registries , Transcatheter Aortic Valve Replacement/adverse effects , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Echocardiography , Female , Follow-Up Studies , Global Health , Humans , Incidence , Male , Postoperative Complications/diagnostic imaging , Prognosis , Prosthesis Design , Retrospective Studies , Time Factors