Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Joints ; 5(4): 249-252, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29270564

ABSTRACT

Congenital insensitivity to pain with anhidrosis (CIPA) is an extremely rare disorder characterized by autonomic and sensory nerves malfunction with insensitivity to both deep and superficial painful stimuli, inability to sweat and produce tears, and mild to moderate mental retardation with self-mutilating behavior. Related consequences of inveterate musculoskeletal injuries represent a major issue for these patients, since pain cannot act as a protection mechanism. For the same reason, the patients are at risk during postoperative rehabilitation, which should be taken into account when selecting an orthopaedic implant. To our knowledge, only one case of total hip arthroplasty has been reported in the literature to date. A 21-year-old Caucasian male patient affected with CIPA arrived at our attention complaining about a functional limitation of the left hip. No history of trauma was reported. The X-rays showed an inveterate femoral neck fracture with a severe necrosis and resorption of the femoral head. We decided to perform a total hip arthroplasty with a cemented stem and a cemented dual mobility cup. The postoperative course and rehabilitation were satisfactory, with excellent clinical results, measured with the Harris Hip Score at 1 year.

2.
Hip Int ; 22(3): 274-9, 2012.
Article in English | MEDLINE | ID: mdl-22740272

ABSTRACT

The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/methods , Femur/surgery , Hip Prosthesis , Prosthesis Design , Prosthesis Failure , Activities of Daily Living , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Cementation , Cohort Studies , Female , Health Status , Humans , Male , Metal-on-Metal Joint Prostheses , Middle Aged , Outcome Assessment, Health Care , Postoperative Complications , Quality of Life , Range of Motion, Articular , Recovery of Function , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...