Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 81
Filter
1.
Circ Cardiovasc Imaging ; 17(3): e016197, 2024 03.
Article in English | MEDLINE | ID: mdl-38440875

ABSTRACT

BACKGROUND: Left atrial (LA) speckle tracking provides detailed information on atrial function. Its utility for predicting subclinical atrial fibrillation (SCAF) is unclear. Therefore, we sought to investigate whether LA strain measures could predict SCAF detected by long-term continuous rhythm monitoring. METHODS: This was an echocardiographic substudy of the LOOP study, where elderly at risk of stroke were randomized to receive a loop recorder (Reveal LINQ) or control. Participants who received a loop recorder were included in this analysis. Echocardiography included LA reservoir, conduit, and contraction strain. Participants were followed with continuous rhythm monitoring for SCAF (≥6 minutes). Cox proportional hazards regression was applied to adjust for atrial fibrillation risk factors. RESULTS: In total, 956 participants were eligible for analysis. Median continuous rhythm monitoring was 35 months (IQR, 20-40 months), during which 278 (29%) were diagnosed with SCAF. The mean age was 74 years, 56% were male, median CHA2DS2-VASc-score was 4. LA reservoir strain was an independent predictor of SCAF after multivariable adjustments (HR, 1.04 [1.02-1.05], per 1% decrease) and so was contraction strain. The findings were unchanged in competing risk analyses and in participants with normal LA size and diastolic function. Participants with low reservoir strain (<33%) had a significantly higher risk of SCAF compared with those with high reservoir strain (incidence rate, 14.5 [12.4-16.9] versus 9.8 [8.2-11.8] events/100 person-years). The same was noted for low versus high contraction strain. CONCLUSIONS: LA reservoir and contraction strain are independent predictors of SCAF in elderly at risk of stroke. This also applies to individuals with normal LA size and diastolic function. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02036450.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Male , Aged , Female , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/complications , Heart Atria/diagnostic imaging , Echocardiography , Stroke/etiology , Stroke/diagnosis
2.
Rev. esp. cardiol. (Ed. impr.) ; 76(12): 970-979, Dic. 2023. ilus, tab, graf
Article in Spanish | IBECS | ID: ibc-228115

ABSTRACT

Introducción y objetivos: El papel de la tomografía por emisión de positrones/tomografía computarizada con 18F-fluorodesoxiglucosa ([18F]FDG-PET/CT) en las infecciones de los dispositivos de electroestimulación cardiaca (DEC) requiere una evaluación más precisa. El objetivo del trabajo es determinar su rendimiento en cada región topográfica del DEC, su capacidad en la diferenciación de infecciones locales aisladas y sistémicas, la utilidad de la captación de bazo y médula ósea (MO) para diferenciar entre infecciones locales y sistémicas y su potencial utilidad en el seguimiento de las infecciones de los DEC. Métodos: Estudio retrospectivo unicéntrico de 54 casos de infección de DEC y 54 controles durante 2014-2021. Se estudió el rendimiento diagnóstico en cada región topográfica del DEC. Se evaluó la combinación de la [18F]FDG-PET/CT con el ecocardiograma transesofágico (ETE) para diagnosticar infecciones sistémicas, el papel de la actividad en MO y bazo y su posible utilidad para guiar la duración de la antibioterapia crónica cuando no se retira el DEC. Resultados: Se incluyeron 13 (24%) infecciones locales aisladas y 41 (76%) infecciones sistémicas. En general, la [18F]FDG-PET/CT mostró un 100% de especificidad y el 85% de sensibilidad, que fue del 79% en el bolsillo, el 57% en el cable subcutáneo, el 22% en el cable endovascular y del 10% en el cable intracardiaco. En las infecciones sistémicas, la [18F]FDG-PET/CT en combinación con ETE aumentó el diagnóstico definitivo del 34 al 56% (p=0,04). Los casos con bacteriemia mostraron hipermetabolismo del bazo (p=0,05) y la MO (p=0,04). Se obtuvo una [18F]FDG-PET/CT de seguimiento de 13 pacientes sin extracción del DEC. No hubo recaídas al suspender la antibioterapia crónica en 6 casos con [18F]FDG-PET/CT negativa. Conclusiones: La sensibilidad de la [18F]FDG-PET/CT para evaluar infecciones locales es mayor que en infecciones sistémicas y aumenta en las sistémicas en combinación con ETE...(AU)


Introduction and objectives: The role of [18F]FDG-PET/CT in cardiac implantable electronic device (CIED) infections requires better evaluation, especially in the diagnosis of systemic infections. We aimed to determine the following: a) the diagnostic accuracy of [18F]FDG-PET/CT in each CIED topographical region, b) the added value of [18F]FDG-PET/CT over transesophageal echocardiography (TEE) in diagnosing systemic infections, c) spleen and bone marrow uptake in differentiating isolated local infections from systemic infections, and d) the potential application of [18F]FDG-PET/CT in follow-up. Methods: Retrospective single-center study including 54 cases and 54 controls from 2014 to 2021. The Primary endpoint was the diagnostic yield of [18F]FDG-PET/CT in each topographical CIED region. Secondary analyses described the performance of [18F]FDG-PET/CT compared with that of TEE in systemic infections, bone marrow and spleen uptake in systemic and isolated local infections, and the potential application of [18F]FDG-PET/CT in guiding cessation of chronic antibiotic suppression when completed device removal is not performed. Results: We analyzed 13 (24%) isolated local infections and 41 (76%) systemic infections. Overall, the specificity of [18F]FDG-PET/CT was 100% and sensitivity 85% (79% pocket, 57% subcutaneous lead, 22% endovascular lead, 10% intracardiac lead). When combined with TEE, [18F]FDG-PET/CT increased definite diagnosis o fsystemic infections from 34% to 56% (P=.04). Systemic infections with bacteremia showed higher spleen (P=.05) and bone marrow metabolism (P=.04) than local infections. Thirteen patients without complete device removal underwent a follow-up [18F]FDG-PET/CT, with no relapses after discontinuation of chronic antibiotic suppression in 6 cases with negative follow-up [18F]FDG-PET/CT. Conclusions: The sensitivity of [18F]FDG-PET/CT for evaluating CIED infections was high in local infections but much lower in systemic infections...(AU)


Subject(s)
Humans , Male , Female , Heart Diseases/diagnostic imaging , Cardiac Pacing, Artificial/methods , Positron Emission Tomography Computed Tomography , Endocarditis/diagnostic imaging , Therapeutics/methods , Cardiovascular Infections/drug therapy , Cardiology , Cardiology Service, Hospital , Retrospective Studies , Case-Control Studies , Spain , Endocarditis/drug therapy
3.
J Pathol ; 260(5): 498-513, 2023 08.
Article in English | MEDLINE | ID: mdl-37608772

ABSTRACT

The clinical significance of the tumor-immune interaction in breast cancer is now established, and tumor-infiltrating lymphocytes (TILs) have emerged as predictive and prognostic biomarkers for patients with triple-negative (estrogen receptor, progesterone receptor, and HER2-negative) breast cancer and HER2-positive breast cancer. How computational assessments of TILs might complement manual TIL assessment in trial and daily practices is currently debated. Recent efforts to use machine learning (ML) to automatically evaluate TILs have shown promising results. We review state-of-the-art approaches and identify pitfalls and challenges of automated TIL evaluation by studying the root cause of ML discordances in comparison to manual TIL quantification. We categorize our findings into four main topics: (1) technical slide issues, (2) ML and image analysis aspects, (3) data challenges, and (4) validation issues. The main reason for discordant assessments is the inclusion of false-positive areas or cells identified by performance on certain tissue patterns or design choices in the computational implementation. To aid the adoption of ML for TIL assessment, we provide an in-depth discussion of ML and image analysis, including validation issues that need to be considered before reliable computational reporting of TILs can be incorporated into the trial and routine clinical management of patients with triple-negative breast cancer. © 2023 The Authors. The Journal of Pathology published by John Wiley & Sons Ltd on behalf of The Pathological Society of Great Britain and Ireland.


Subject(s)
Mammary Neoplasms, Animal , Triple Negative Breast Neoplasms , Humans , Animals , Lymphocytes, Tumor-Infiltrating , Biomarkers , Machine Learning
4.
Clin Infect Dis ; 77(4): 518-526, 2023 08 22.
Article in English | MEDLINE | ID: mdl-37138445

ABSTRACT

The microbiology, epidemiology, diagnostics, and treatment of infective endocarditis (IE) have changed significantly since the Duke Criteria were published in 1994 and modified in 2000. The International Society for Cardiovascular Infectious Diseases (ISCVID) convened a multidisciplinary Working Group to update the diagnostic criteria for IE. The resulting 2023 Duke-ISCVID IE Criteria propose significant changes, including new microbiology diagnostics (enzyme immunoassay for Bartonella species, polymerase chain reaction, amplicon/metagenomic sequencing, in situ hybridization), imaging (positron emission computed tomography with 18F-fluorodeoxyglucose, cardiac computed tomography), and inclusion of intraoperative inspection as a new Major Clinical Criterion. The list of "typical" microorganisms causing IE was expanded and includes pathogens to be considered as typical only in the presence of intracardiac prostheses. The requirements for timing and separate venipunctures for blood cultures were removed. Last, additional predisposing conditions (transcatheter valve implants, endovascular cardiac implantable electronic devices, prior IE) were clarified. These diagnostic criteria should be updated periodically by making the Duke-ISCVID Criteria available online as a "Living Document."


Subject(s)
Communicable Diseases , Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis , Humans , Endocarditis, Bacterial/microbiology , Endocarditis/etiology , Fluorodeoxyglucose F18 , Positron-Emission Tomography , Communicable Diseases/complications
5.
Rev Esp Cardiol (Engl Ed) ; 76(12): 970-979, 2023 Dec.
Article in English, Spanish | MEDLINE | ID: mdl-37028797

ABSTRACT

INTRODUCTION AND OBJECTIVES: The role of [18F]FDG-PET/CT in cardiac implantable electronic device (CIED) infections requires better evaluation, especially in the diagnosis of systemic infections. We aimed to determine the following: a) the diagnostic accuracy of [18F]FDG-PET/CT in each CIED topographical region, b) the added value of [18F]FDG-PET/CT over transesophageal echocardiography (TEE) in diagnosing systemic infections, c) spleen and bone marrow uptake in differentiating isolated local infections from systemic infections, and d) the potential application of [18F]FDG-PET/CT in follow-up. METHODS: Retrospective single-center study including 54 cases and 54 controls from 2014 to 2021. The Primary endpoint was the diagnostic yield of [18F]FDG-PET/CT in each topographical CIED region. Secondary analyses described the performance of [18F]FDG-PET/CT compared with that of TEE in systemic infections, bone marrow and spleen uptake in systemic and isolated local infections, and the potential application of [18F]FDG-PET/CT in guiding cessation of chronic antibiotic suppression when completed device removal is not performed. RESULTS: We analyzed 13 (24%) isolated local infections and 41 (76%) systemic infections. Overall, the specificity of [18F]FDG-PET/CT was 100% and sensitivity 85% (79% pocket, 57% subcutaneous lead, 22% endovascular lead, 10% intracardiac lead). When combined with TEE, [18F]FDG-PET/CT increased definite diagnosis o fsystemic infections from 34% to 56% (P=.04). Systemic infections with bacteremia showed higher spleen (P=.05) and bone marrow metabolism (P=.04) than local infections. Thirteen patients without complete device removal underwent a follow-up [18F]FDG-PET/CT, with no relapses after discontinuation of chronic antibiotic suppression in 6 cases with negative follow-up [18F]FDG-PET/CT. CONCLUSIONS: The sensitivity of [18F]FDG-PET/CT for evaluating CIED infections was high in local infections but much lower in systemic infections. However, accuracy increased when [18F]FDG-PET/CT was combined with TEE in endovascular lead bacteremic infection. Spleen and bone marrow hypermetabolism could differentiate bacteremic systemic infection from local infection. Although further prospective studies are needed, follow-up [18F]FDG-PET/CT could play a potential role in the management of chronic antibiotic suppression therapy when complete device removal is unachievable.


Subject(s)
Defibrillators, Implantable , Heart Diseases , Pacemaker, Artificial , Prosthesis-Related Infections , Sepsis , Humans , Positron Emission Tomography Computed Tomography , Fluorodeoxyglucose F18 , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Radiopharmaceuticals/pharmacology , Retrospective Studies , Heart Diseases/therapy , Anti-Bacterial Agents , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/therapy
6.
Clin Infect Dis ; 76(11): 2042-2043, 2023 Jun 08.
Article in English | MEDLINE | ID: mdl-36881936
7.
Infection ; 51(5): 1513-1522, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36959526

ABSTRACT

PURPOSE: Streptococcal bloodstream infections (BSIs) are common, yet prognostic factors are poorly investigated. We aimed to investigate the mortality according to streptococcal species and seasonal variation. METHODS: Patients with streptococcal BSIs from 2008 to 2017 in the Capital Region of Denmark were investigated, and data were crosslinked with nationwide registers for the identification of comorbidities. A multivariable logistic regression analysis was performed to assess mortality according to streptococcal species and season of infection. RESULTS: Among 6095 patients with a streptococcal BSI (mean age 68.1 years), the 30-day mortality was 16.1% and the one-year mortality was 31.5%. With S. pneumoniae as a reference, S. vestibularis was associated with a higher adjusted mortality both within 30 days (odds ratio (OR) 2.89 [95% confidence interval (CI) 1.20-6.95]) and one year (OR 4.09 [95% CI 1.70-9.48]). One-year mortality was also higher in S. thermophilus, S. constellatus, S. parasanguinis, S. salivarius, S. anginosus, and S. mitis/oralis. However, S. mutans was associated with a lower one-year mortality OR 0.44 [95% CI 0.20-0.97], while S. gallolyticus was associated with both a lower 30-day (OR 0.42 [95% CI 0.26-0.67]) and one-year mortality (OR 0.66 [95% CI 0.48-0.93]). Furthermore, with infection in the summer as a reference, patients infected in the winter and autumn had a higher association with 30-day mortality. CONCLUSIONS: The mortality in patients with streptococcal BSI was associated with streptococcal species. Further, patients with streptococcal BSIs infected in the autumn and winter had a higher risk of death within 30 days, compared with patients infected in the summer.


Subject(s)
Bacteremia , Sepsis , Streptococcal Infections , Humans , Aged , Prognosis , Streptococcus , Streptococcal Infections/epidemiology , Streptococcus pneumoniae
8.
Expert Rev Anti Infect Ther ; 21(3): 281-293, 2023 03.
Article in English | MEDLINE | ID: mdl-36744387

ABSTRACT

INTRODUCTION: Methicillin-resistant and -susceptible Staphylococcus aureus (MRSA/MSSA) infections are a major global health-care problem. Bacteremia with S. aureus exhibits high rates of morbidity and mortality and can cause complicated infections such as infective endocarditis (IE). The emerging resistance profile of S. aureus is worrisome, and several international agencies have appealed for new treatment approaches to be developed. AREAS COVERED: Daptomycin presents a rapid bactericidal effect against MRSA and has been considered at least as effective as vancomycin in treating MRSA bacteremia. However, therapy failure is often related to deep-seated infections, e.g. endocarditis, with high bacterial inocula and daptomycin regimens <10 mg/kg/day. Current antibiotic options for treating invasive S. aureus infections have limitations in monotherapy. Daptomycin in combination with other antibiotics, e.g. fosfomycin, may be effective in improving clinical outcomes in patients with MRSA IE. EXPERT OPINION: Exploring therapeutic combinations has shown fosfomycin to have a unique mechanism of action and to be the most effective option in preventing the onset of resistance to and optimizing the efficacy of daptomycin, suggesting the synergistic combination of fosfomycin with daptomycin is a useful alternative treatment option for MSSA or MRSA IE.


Subject(s)
Bacteremia , Daptomycin , Endocarditis, Bacterial , Endocarditis , Fosfomycin , Methicillin-Resistant Staphylococcus aureus , Staphylococcal Infections , Humans , Daptomycin/pharmacology , Daptomycin/therapeutic use , Fosfomycin/adverse effects , Staphylococcus aureus , Anti-Bacterial Agents/therapeutic use , Endocarditis, Bacterial/drug therapy , Endocarditis, Bacterial/microbiology , Staphylococcal Infections/drug therapy , Staphylococcal Infections/microbiology , Endocarditis/drug therapy , Endocarditis/microbiology , Bacteremia/microbiology , Microbial Sensitivity Tests
9.
Neuroinformatics ; 21(2): 269-286, 2023 04.
Article in English | MEDLINE | ID: mdl-36809643

ABSTRACT

Magnetic resonance imaging (MRI) and light-sheet fluorescence microscopy (LSFM) are technologies that enable non-disruptive 3-dimensional imaging of whole mouse brains. A combination of complementary information from both modalities is desirable for studying neuroscience in general, disease progression and drug efficacy. Although both technologies rely on atlas mapping for quantitative analyses, the translation of LSFM recorded data to MRI templates has been complicated by the morphological changes inflicted by tissue clearing and the enormous size of the raw data sets. Consequently, there is an unmet need for tools that will facilitate fast and accurate translation of LSFM recorded brains to in vivo, non-distorted templates. In this study, we have developed a bidirectional multimodal atlas framework that includes brain templates based on both imaging modalities, region delineations from the Allen's Common Coordinate Framework, and a skull-derived stereotaxic coordinate system. The framework also provides algorithms for bidirectional transformation of results obtained using either MR or LSFM (iDISCO cleared) mouse brain imaging while the coordinate system enables users to easily assign in vivo coordinates across the different brain templates.


Subject(s)
Brain , Magnetic Resonance Imaging , Animals , Mice , Brain/diagnostic imaging , Brain/anatomy & histology , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods , Brain Mapping/methods , Skull/diagnostic imaging
10.
IEEE Trans Pattern Anal Mach Intell ; 45(2): 2310-2329, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35471866

ABSTRACT

Minimum cut/maximum flow (min-cut/max-flow) algorithms solve a variety of problems in computer vision and thus significant effort has been put into developing fast min-cut/max-flow algorithms. As a result, it is difficult to choose an ideal algorithm for a given problem. Furthermore, parallel algorithms have not been thoroughly compared. In this paper, we evaluate the state-of-the-art serial and parallel min-cut/max-flow algorithms on the largest set of computer vision problems yet. We focus on generic algorithms, i.e., for unstructured graphs, but also compare with the specialized GridCut implementation. When applicable, GridCut performs best. Otherwise, the two pseudoflow algorithms, Hochbaum pseudoflow and excesses incremental breadth first search, achieves the overall best performance. The most memory efficient implementation tested is the Boykov-Kolmogorov algorithm. Amongst generic parallel algorithms, we find the bottom-up merging approach by Liu and Sun to be best, but no method is dominant. Of the generic parallel methods, only the parallel preflow push-relabel algorithm is able to efficiently scale with many processors across problem sizes, and no generic parallel method consistently outperforms serial algorithms. Finally, we provide and evaluate strategies for algorithm selection to obtain good expected performance. We make our dataset and implementations publicly available for further research.

12.
Infection ; 51(4): 869-879, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36152224

ABSTRACT

PURPOSE: Infective endocarditis (IE) is frequently caused by streptococcal species, yet clinical features and mortality are poorly investigated. Our aim was to examine patients with streptococcal IE to describe clinical features and outcomes according to streptococcal species. METHODS: From 2002 to 2012, we investigated patients with IE admitted to two tertiary Danish heart centres. Adult patients with left-sided streptococcal IE were included. Adjusted multivariable logistic regression analyses were performed, to assess the association between streptococcal species and heart valve surgery or 1-year mortality. RESULTS: Among 915 patients with IE, 284 (31%) patients with streptococcal IE were included [mean age 63.5 years (SD 14.1), 69% men]. The most frequent species were S. mitis/oralis (21%) and S. gallolyticus (17%). Fever (86%) and heart murmur (81%) were common symptoms, while dyspnoea was observed in 46%. Further, 18% of all cases were complicated by a cardiac abscess/pseudoaneurysm and 25% by an embolic event. Heart valve surgery during admission was performed in 55% of all patients, and S. gallolyticus (OR 0.28 [95% CI 0.11-0.69]) was associated with less surgery compared with S. mitis/oralis. In-hospital mortality was 7% and 1-year mortality 15%, without any difference between species. CONCLUSION: S. mitis/oralis and S. gallolyticus were the most frequent streptococcal species causing IE. Further, S. gallolyticus IE was associated with less heart valve surgery during admission compared with S. mitis/oralis IE. Being aware of specific symptoms, clinical findings, and complications related to different streptococcal species, may help the clinicians in expecting different outcomes.


Subject(s)
Cardiac Surgical Procedures , Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis , Staphylococcal Infections , Streptococcal Infections , Adult , Male , Humans , Middle Aged , Female , Endocarditis, Bacterial/diagnosis , Endocarditis/diagnosis , Endocarditis/epidemiology , Streptococcus , Retrospective Studies , Streptococcal Infections/epidemiology
13.
Open Forum Infect Dis ; 9(12): ofac647, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36540385

ABSTRACT

Background: Staphylococcus aureus bacteremia (SAB) can be community-acquired or healthcare-associated, and prior small studies have suggested that this mode of acquisition impacts the subsequent prevalence of infective endocarditis (IE) and patient outcomes. Methods: First-time SAB was identified from 2010 to 2018 using Danish nationwide registries and categorized into community-acquired (no healthcare contact within 30 days) or healthcare-associated (SAB >48 hours of hospital admission, hospitalization within 30 days, or outpatient hemodialysis). Prevalence of IE (defined from hospital codes) was compared between groups using multivariable adjusted logistic regression analysis. One-year mortality of S aureus IE (SAIE) was compared between groups using multivariable adjusted Cox proportional hazard analysis. Results: We identified 5549 patients with community-acquired SAB and 7491 with healthcare-associated SAB. The prevalence of IE was 12.1% for community-acquired and 6.6% for healthcare-associated SAB. Community-acquired SAB was associated with a higher odds of IE as compared with healthcare-associated SAB (odds ratio, 2.12 [95% confidence interval {CI}, 1.86-2.41]). No difference in mortality was observed with 0-40 days of follow-up for community-acquired SAIE as compared with healthcare-associated SAIE (HR, 1.07 [95% CI, .83-1.37]), while with 41-365 days of follow-up, community-acquired SAIE was associated with a lower mortality (HR, 0.71 [95% CI, .53-.95]). Conclusions: Community-acquired SAB was associated with twice the odds for IE, as compared with healthcare-associated SAB. We identified no significant difference in short-term mortality between community-acquired and healthcare-associated SAIE. Beyond 40 days of survival, community-acquired SAIE was associated with a lower mortality.

14.
PLoS One ; 17(6): e0269475, 2022.
Article in English | MEDLINE | ID: mdl-35658048

ABSTRACT

BACKGROUND: Elderly individuals occupy an increasing part of the general population. Conventional and speckle-tracking transthoracic echocardiography may help guide risk stratification in these individuals. The purpose of this study was to evaluate the potential utility of conventional and speckle-tracking echocardiography in the screening of cardiac abnormalities in the elderly population. METHODS: Two cohorts of elderly individuals (sample size: 1441 and 944) were analyzed, who were part of a randomized controlled clinical trial (LOOP study) and of an observational study (Copenhagen City Heart Study), recruiting participants from the general population >70 years of age with cardiovascular risk factors (arterial hypertension, diabetes mellitus, heart failure, or prior stroke) and sinus rhythm. Participants underwent a comprehensive transthoracic echocardiographic examination, including myocardial speckle tracking. Cardiac abnormalities were defined according to the ASE/EACVI guidelines. RESULTS: Structural cardiac abnormalities such as left ventricular (LV) remodeling, mitral annular calcification (MAC), and aortic valve sclerosis (with or without stenosis) were highly prevalent in the LOOP study (40%, 39%, and 27%, respectively). Moreover, a high prevalence of functional cardiac alterations such as LV diastolic dysfunction (LVDD), abnormal LV longitudinal systolic strain (GLS), and abnormal left atrial (LA) reservoir strain was present in the LOOP study (27%, 18%, and 9%, respectively). Likewise, the rate of LVDD, abnormal GLS, and abnormal LA reservoir strain was comparable in the validation sample from the Copenhagen City Heart Study. In line with these findings, subjects with LV remodeling, MAC, and aortic valve changes had a higher prevalence of LVDD, abnormal GLS, and abnormal LA reservoir strain than those without structural cardiac alterations. CONCLUSION: The findings of this study highlight the potential clinical utility of conventional and speckle-tracking echocardiography in the screening of structural and functional cardiac abnormalities in the elderly population. Further studies are warranted to determine the prognostic relevance of these findings.


Subject(s)
Calcinosis , Heart Defects, Congenital , Ventricular Dysfunction, Left , Aged , Echocardiography , Heart Atria , Humans , Ventricular Function, Left , Ventricular Remodeling
15.
Zoology (Jena) ; 153: 126023, 2022 08.
Article in English | MEDLINE | ID: mdl-35717730

ABSTRACT

The large interspecific variation in marine mammal skull and dental morphology reflects ecological specialisations to foraging and communication. At the intraspecific level, the drivers of skull shape variation are less well understood, having implications for identifying putative local foraging adaptations and delineating populations and subspecies for taxonomy, systematics, management and conservation. Here, we assess the range-wide intraspecific variation in 71 grey seal skulls by 3D surface scanning, collection of cranial landmarks and geometric morphometric analysis. We find that skull shape differs slightly between populations in the Northwest Atlantic, Northeast Atlantic and Baltic Sea. However, there was a large shape overlap between populations and variation was substantially larger among animals within populations than between. We hypothesize that this pattern of intraspecific variation in grey seal skull shape results from balancing selection or phenotypic plasticity allowing for a remarkably generalist foraging behaviour. Moreover, the large overlap in skull shape between populations implies that the separate subspecies status of Atlantic and Baltic Sea grey seals is questionable from a morphological point of view.


Subject(s)
Seals, Earless , Animals , Baltic States , Head , Skull
16.
Clin Infect Dis ; 75(6): 1097-1102, 2022 09 29.
Article in English | MEDLINE | ID: mdl-35262664

ABSTRACT

The modified Duke criteria requires that Enterococcus faecalis bacteremia must be both community-acquired and without known focus in order to be considered a microbiological "Major" diagnostic criterion in the diagnosis of infective endocarditis. We believe that the microbiological diagnostic criteria should be updated to regard E. faecalis as a "typical" endocarditis bacterium as is currently the case, for example, viridans group streptococci and Staphylococcus aureus. Using data from a prospective study of 344 patients with E. faecalis bacteremia evaluated with echocardiography, we demonstrate that designating E. faecalis as a "typical" endocarditis pathogen, regardless the place of acquisition or the portal of entry, improved the sensitivity to correctly identify definite endocarditis from 70% (modified Duke criteria) to 96% (enterococcal adjusted Duke criteria).


Subject(s)
Bacteremia , Endocarditis, Bacterial , Endocarditis , Bacteremia/diagnosis , Bacteremia/microbiology , Bacteria , Endocarditis/microbiology , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/microbiology , Enterococcus faecalis , Humans , Prospective Studies
17.
Eur Heart J Qual Care Clin Outcomes ; 9(1): 24-33, 2022 12 13.
Article in English | MEDLINE | ID: mdl-35259247

ABSTRACT

AIMS: Little is known about the mortality for patients with infective endocarditis (IE) on a nationwide scale, and previous studies have been conducted in selected cohorts from tertiary centers. We aimed to investigate temporal trends in mortality using nationwide Danish registries. METHODS AND RESULTS: We identified patients with first-time IE between 1999-2018, and they were grouped by calendar periods (1999-2003, 2004-2008, 2009-2013, 2014-2018). One-year mortality was estimated using Kaplan-Meier estimates. For calendar periods, odds ratios (ORs) and hazard ratios (HRs) were computed using multivariable adjusted logistic regression and Cox proportional Hazards analyses for in-hospital and one-year mortality, respectively. We identified 8804 patients with IE. Age and proportions of men were: 66.7 (25th-75th percentile: 53.4-76.7) years and 59.9% in 1999-2003 and 72.8 (25th-75th percentile: 63.4-80.3) and 65.8% in 2014-2018. In-hospital mortality was 1999-2003: 24.5%, 2004-2008: 22.8%, 2009-2013: 18.8%, and 2014-2018: 18.3%. Relative to 1999-2003, adjusted likelihoods of in-hospital mortality were: OR = 0.81 (95% CI: 0.69-0.96) in 2004-2008, OR = 0.59 (95% CI: 0.50-0.69) in 2009-2013, and OR = 0.51 (95% CI: 0.43-0.60) in 2014-2018. By calendar periods, crude risks of one-year mortality were: 34.4% (95% CI: 32.0-36.8%), 33.5% (95% CI: 31.5-35.6%), 32.1% (95% CI: 30.2-34.0%), and 33.1% (95% CI: 31.3-34.8%). Relative to 1999-2003, adjusted rates of one-year mortality were: HR = 0.88 (95% CI 0.79-0.99) in 2004-2008, HR = 0.76 (95% CI: 0.68-0.86) in 2009-2013, and HR = 0.72 (95% CI: 0.64-0.81) in 2014-2018. CONCLUSION: In this nationwide study of patients with first-time IE between 1999-2018, both short- and long-term survival has improved over time when accounting for changes in patient characteristics. ONE-SENTENCE SUMMARY: When accounting for patient characteristics, both short- and long-term mortality have improved in patients with first-time infective endocarditis.


Subject(s)
Endocarditis , Male , Humans , Risk Factors , Follow-Up Studies , Registries , Hospital Mortality
18.
PeerJ ; 10: e12869, 2022.
Article in English | MEDLINE | ID: mdl-35186472

ABSTRACT

To study the shape of objects using geometric morphometrics, landmarks are oftentimes collected digitally from a 3D scanned model. The expert may annotate landmarks using software that visualizes the 3D model on a flat screen, and interaction is achieved with a mouse and a keyboard. However, landmark annotation of a 3D model on a 2D display is a tedious process and potentially introduces error due to the perception and interaction limitations of the flat interface. In addition, digital landmark placement can be more time-consuming than direct annotation on the physical object using a tactile digitizer arm. Since virtual reality (VR) is designed to more closely resemble the real world, we present a VR prototype for annotating landmarks on 3D models. We study the impact of VR on annotation performance by comparing our VR prototype to Stratovan Checkpoint, a commonly used commercial desktop software. We use an experimental setup, where four operators placed six landmarks on six grey seal (Halichoerus grypus) skulls in six trials for both systems. This enables us to investigate multiple sources of measurement error. We analyse both for the configuration and for single landmarks. Our analysis shows that annotation in VR is a promising alternative to desktop annotation. We find that annotation precision is comparable between the two systems, with VR being significantly more precise for one of the landmarks. We do not find evidence that annotation in VR is faster than on the desktop, but it is accurate.


Subject(s)
Skull , Virtual Reality , Software , Mathematics
19.
Article in English | MEDLINE | ID: mdl-34981209

ABSTRACT

Four-dimensional (4D) echocardiography may provide more accurate estimations of left atrial (LA) volumes than 2-dimensional (2D) measures. We sought to compare the concordance of a novel 4D LA quantification software versus 2D echocardiography against cardiac magnetic resonance (CMR). This was a multimodality imaging substudy of a randomized clinical trial (the LOOP study). Elderly participants with stroke risk factors were included. A subgroup of this study population underwent transthoracic echocardiography (n = 1441) and a subset underwent CMR within two weeks (n = 73). The mean age of the echocardiographic study population was 74 years and 54% were men. The maximal LA volume (LAVmax) was 47 mL by 2D, 52 mL by 4D, and 104 mL by CMR. While 2D echocardiography showed a moderate correlation with 4D (R2 = 0.51) it yielded significantly lower values for LAVmax with a mean difference of 4.5 ± 11.9 mL, p < 0.001. 4D echocardiography correlated strongly with CMR measurements (R2 = 0.70), whereas 2D echocardiography showed a moderate correlation (R2 = 0.53). However, both modalities systematically underestimated LAVmax largely compared to CMR (2D vs. CMR: - 54.9 ± 21.3 mL; 4D vs. CMR: - 49.7 ± 18.6 mL). Similar observations were made for minimal LA volume and LA volume before atrial contraction. Analyses time by 4D was shorter than for 2D (90 ± 11 vs. 118 ± 16 s, p < 0.001). Intra- and interobserver variability was lower for 4D than 2D. Four-dimensional echocardiography is faster, more reproducible, and correlates more closely to CMR than 2D echocardiography. Both 4D and 2D echocardiography systematically underestimates LA volumes compared to CMR, emphasizing that values of LA volumes are not interchangeable between echocardiography and CMR.

20.
BMC Zool ; 7(1): 10, 2022 Feb 04.
Article in English | MEDLINE | ID: mdl-37170292

ABSTRACT

BACKGROUND: Understanding the diversity of eyes is crucial to unravel how different animals use vision to interact with their respective environments. To date, comparative studies of eye anatomy are scarce because they often involve time-consuming or inefficient methods. X-ray micro-tomography (micro-CT) is a promising high-throughput imaging technique that enables to reconstruct the 3D anatomy of eyes, but powerful tools are needed to perform fast conversions of anatomical reconstructions into functional eye models. RESULTS: We developed a computing method named InSegtCone to automatically segment the crystalline cones in the apposition compound eyes of arthropods. Here, we describe the full auto-segmentation process, showcase its application to three different insect compound eyes and evaluate its performance. The auto-segmentation could successfully label the full individual shapes of 60-80% of the crystalline cones and is about as accurate and 250 times faster than manual labelling of the individual cones. CONCLUSIONS: We believe that InSegtCone can be an important tool for peer scientists to measure the orientation, size and dynamics of crystalline cones, leading to the accurate optical modelling of the diversity of arthropod eyes with micro-CT.

SELECTION OF CITATIONS
SEARCH DETAIL
...