Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 63(22): 225016, 2018 11 12.
Article in English | MEDLINE | ID: mdl-30418940

ABSTRACT

In carbon ion therapy treatment planning, the relative biological effectiveness (RBE) is accounted for by optimization of the RBE-weighted dose (biological dose). The RBE calculation methods currently applied clinically in carbon ion therapy are derived from the microdosimetric kinetic model (MKM) in Japan and the local effect model (LEM) in Europe. The input parameters of these models are based on fit to experimental data subjected to uncertainties. We therefore performed a sensitivity study of the MKM input parameters, i.e. the domain radius (r d ), the nucleus radius (R n ) and the parameters of the linear quadratic (LQ) model (α x and ß). The study was performed with the FLUKA Monte Carlo code, using spread out Bragg peak (SOBP) scenarios in water and a biological dose distribution in a clinical patient case. Comparisons were done between biological doses estimated applying the MKM with parameters based on HSG cells, and with HSG parameters varied separately by ±{5, 25, 50}%. Comparisons were also done between parameter sets from different cell lines (HSG, V79, CHO and T1), as well as versions of the LEM. Of the parameters, r d had the largest impact on the biological dose distribution, especially on the absolute dose values. Increasing this parameter by 25% decreased the biological dose level at the center of a 3 Gy(RBE) SOBP by 14%. Variations in R n only influenced the biological dose distribution towards the particle range, and variations in α x resulted in minor changes in the biological dose, with an increasing impact towards the particle range. ß had the overall smallest influence on the SOBPs, but the impact could become more pronounced if alternative (LET dependent) implementations are used. The resulting percentage change in the SOBPs was generally less than the percentage change in the parameters. The patient case showed similar effects as with the SOBPs in water, and parameter variations had similar impact on the biological dose when using the clinical MKM and the general MKM. The clinical LEM calculated the highest biological doses to both tumor and surrounding healthy tissues, with a median target dose (D 50%) of 40.5 Gy(RBE), while the MKM with HSG and V79 parameters resulted in a D 50% of 34.2 and 36.9 Gy(RBE), respectively. In all, the observed change in biological dose distribution due to parameter variations demonstrates the importance of accurate input parameters when applying the MKM in treatment planning.


Subject(s)
Heavy Ion Radiotherapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Animals , CHO Cells , Cell Line , Cricetinae , Cricetulus , Heavy Ion Radiotherapy/standards , Humans , Relative Biological Effectiveness
2.
Phys Med Biol ; 62(9): 3814-3827, 2017 05 07.
Article in English | MEDLINE | ID: mdl-28252446

ABSTRACT

Particle therapy facilities often require Monte Carlo (MC) simulations to overcome intrinsic limitations of analytical treatment planning systems (TPS) related to the description of the mixed radiation field and beam interaction with tissue inhomogeneities. Some of these uncertainties may affect the computation of effective dose distributions; therefore, particle therapy dedicated MC codes should provide both absorbed and biological doses. Two biophysical models are currently applied clinically in particle therapy: the local effect model (LEM) and the microdosimetric kinetic model (MKM). In this paper, we describe the coupling of the NIRS (National Institute for Radiological Sciences, Japan) clinical dose to the FLUKA MC code. We moved from the implementation of the model itself to its application in clinical cases, according to the NIRS approach, where a scaling factor is introduced to rescale the (carbon-equivalent) biological dose to a clinical dose level. A high level of agreement was found with published data by exploring a range of values for the MKM input parameters, while some differences were registered in forward recalculations of NIRS patient plans, mainly attributable to differences with the analytical TPS dose engine (taken as reference) in describing the mixed radiation field (lateral spread and fragmentation). We presented a tool which is being used at the Italian National Center for Oncological Hadrontherapy to support the comparison study between the NIRS clinical dose level and the LEM dose specification.


Subject(s)
Heavy Ion Radiotherapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Carbon Radioisotopes/therapeutic use , Humans , Monte Carlo Method , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...