Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(6)2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38544264

ABSTRACT

Imaging using scattering media is a very important yet challenging technology. As one of the most widely used scattering imaging methods, speckle autocorrelation technology has important applications in several fields. However, traditional speckle autocorrelation imaging methods usually use iterative phase recovery algorithms to obtain the Fourier phase of hidden objects, posing issues such as large data calculation volumes and uncertain reconstruction results. Here, we propose a single-shot scattering imaging method based on the bispectrum truncation method. The bispectrum analysis is utilized for hidden object phase recovery, the truncation method is used to avoid the computation of redundant data when calculating the bispectrum data, and the method is experimentally verified. The experimental results show that our method does not require uncertain iterative calculations and can reduce the bispectrum data computation by more than 80% by adjusting the truncation factor without damaging the imaging quality, which greatly improves imaging efficiency. This method paves the way for rapid imaging through scattering media and brings benefits for imaging in dynamic situations.

2.
Sensors (Basel) ; 23(10)2023 May 19.
Article in English | MEDLINE | ID: mdl-37430807

ABSTRACT

Conventional eddy-current sensors have the advantages of being contactless and having high bandwidth and high sensitivity. They are widely used in micro-displacement measurement, micro-angle measurement, and rotational speed measurement. However, they are based on the principle of impedance measurement, so the influence of temperature drift on sensor accuracy is difficult to overcome. A differential digital demodulation eddy current sensor system was designed to reduce the influence of temperature drift on the output accuracy of the eddy current sensor. The differential sensor probe was used to eliminate common-mode interference caused by temperature, and the differential analog carrier signal was digitized by a high-speed ADC. In the FPGA, the amplitude information is resolved using the double correlation demodulation method. The main sources of system errors were determined, and a test device was designed using a laser autocollimator. Tests were conducted to measure various aspects of sensor performance. Testing showed the following metrics for the differential digital demodulation eddy current sensor: nonlinearity 0.68% in the range of ±2.5 mm, resolution 760 nm, maximum bandwidth 25 kHz, and significant suppression in the temperature drift compared to analog demodulation methods. The tests show that the sensor has high precision, low temperature drift and great flexibility, and it can instead of conventional sensors in applications with large temperature variability.

3.
Sensors (Basel) ; 23(11)2023 May 27.
Article in English | MEDLINE | ID: mdl-37299856

ABSTRACT

Three-dimensional (3D) reconstruction of objects using the polarization properties of diffuse light on the object surface has become a crucial technique. Due to the unique mapping relation between the degree of polarization of diffuse light and the zenith angle of the surface normal vector, polarization 3D reconstruction based on diffuse reflection theoretically has high accuracy. However, in practice, the accuracy of polarization 3D reconstruction is limited by the performance parameters of the polarization detector. Improper selection of performance parameters can result in large errors in the normal vector. In this paper, the mathematical models that relate the polarization 3D reconstruction errors to the detector performance parameters including polarizer extinction ratio, polarizer installation error, full well capacity and analog-to-digital (A2D) bit depth are established. At the same time, polarization detector parameters suitable for polarization 3D reconstruction are provided by the simulation. The performance parameters we recommend include an extinction ratio ≥ 200, an installation error ∈ [-1°, 1°], a full-well capacity ≥ 100 Ke-, and an A2D bit depth ≥ 12 bits. The models provided in this paper are of great significance for improving the accuracy of polarization 3D reconstruction.


Subject(s)
Imaging, Three-Dimensional , Models, Theoretical , Imaging, Three-Dimensional/methods , Computer Simulation
SELECTION OF CITATIONS
SEARCH DETAIL
...