Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Radiol Med ; 122(5): 353-360, 2017 May.
Article in English | MEDLINE | ID: mdl-28197872

ABSTRACT

PURPOSE: To compare the diagnostic accuracy of three-dimensional (3D) fast spin echo (FSE) intermediate-weighed (IW-3D) and 3D hybrid double-echo steady-state T1-weighted sequences (Hy-3D) and two-dimensional (FSE) images (2D) at shoulder MR arthrography (MRA). MATERIALS AND METHODS: Institutional review board approval was obtained and informed consent was waived for this retrospective study. From September 2011 to October 2014, 102 patients who had undergone 1.5 Tesla MRA of the shoulder, including conventional 2D-FSE and IW-3D and Hy-3D images were included in our study. The mean interval between MRA and surgery was 21 days (range 2-70 days). MR images were retrospectively and independently reviewed by two experienced radiologists blinded to the clinical and surgical data. Supraspinatus tendon (SST), infraspinatus tendon (IST) and subscapularis tendon (SCT) tears, as well as antero-inferior, superior and posterior labral lesions were assessed, using surgery as the reference standard. Each reader's performance in assessing rotator cuff and labrum abnormalities was evaluated using the area under the receiver operating characteristic curve (AUC) and 95% confidence intervals (CIs). The difference was evaluated using a univariate z test. The sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV) and accuracy (Acc) for all types of rotator cuff tears and labral lesions were calculated. A value of p < 0.05 was considered statistically significant. Inter-observer agreement was calculated using kappa statistics. RESULTS: The difference of diagnostic accuracy achieved was not significant (p > 0.05). In particular, differences in AUC values ranged from 0.002 (p = 0.98) to 0.014 (p = 0.82) as regards the comparison between 2D and IW-3D images, from 0.002 (p = 0.98) to 0.034 (p = 0.08) concerning the comparison between 2D and Hy-3D images and from 0.010 (p = 0.82) to 0.032 (p = 0.09) when comparing Hy-3D to IW-3D images. Accuracy values in evaluating RC lesions and labral lesions were 95.1, 92.1, 91.2, 93.1, 93.1 and 94.1% by reading 2D, Hy-3D and IW-3D images, respectively. The difference of diagnostic accuracy achieved using the datasets analyzed was not significant (p > 0.05). Inter-observer agreement was very good for each of the datasets that were evaluated, with near-perfect agreement for 2D dataset (k = 0.86), Hy-3D (k = 0.81) and IW-3D (k = 0.83). CONCLUSIONS: The accuracy of IW-3D and Hy-3D images was not significantly higher than the 2D sequences in evaluating RC and labral lesions.


Subject(s)
Arthrography/methods , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Shoulder Injuries , Shoulder Joint/diagnostic imaging , Adolescent , Adult , Female , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Young Adult
2.
World J Radiol ; 7(10): 319-28, 2015 Oct 28.
Article in English | MEDLINE | ID: mdl-26516428

ABSTRACT

Magnetic resonance imaging (MRI) is a reliable and accurate imaging method for the evaluation of patients with pancreatic ductal adenocarcinoma (PDAC). Diffusion-weighted imaging (DWI) is a relatively recent technological improvement that expanded MRI capabilities, having brought functional aspects into conventional morphologic MRI evaluation. DWI can depict the random diffusion of water molecules within tissues (the so-called Brownian motions). Modifications of water diffusion induced by different factors acting on the extracellular and intracellular spaces, as increased cell density, edema, fibrosis, or altered functionality of cell membranes, can be detected using this MR sequence. The intravoxel incoherent motion (IVIM) model is an advanced DWI technique that consent a separate quantitative evaluation of all the microscopic random motions that contribute to DWI, which are essentially represented by molecular diffusion and blood microcirculation (perfusion). Technological improvements have made possible the routine use of DWI during abdominal MRI study. Several authors have reported that the addition of DWI sequence can be of value for the evaluation of patients with PDAC, especially improving the staging; nevertheless, it is still unclear whether and how DWI could be helpful for identification, characterization, prognostic stratification and follow-up during treatment. The aim of this paper is to review up-to-date literature data regarding the applications of DWI and IVIM to PDACs.

3.
Australas J Ultrasound Med ; 17(3): 96-109, 2014 Aug.
Article in English | MEDLINE | ID: mdl-28191218

ABSTRACT

Indication/purpose: To review contrast-enhanced ultrasound features of the most common pancreatic tumours. Methods: Contrast-enhanced ultrasound (CEUS) can provide distinctive features of pancreatic tumours that are reported in the present paper, providing radiologic-pathological correlations and clarifying the main differential diagnosis. Conclusion: Contrast-enhanced ultrasound plays a well-established role in the evaluation of pancreatic tumours. When possible, CEUS should be always performed after the initial US diagnosis, in order to improve the accuracy of the first line examination.

SELECTION OF CITATIONS
SEARCH DETAIL
...