J Maxillofac Oral Surg ; 21(2): 413-419, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35712384

ABSTRACT

Purpose: Trauma is a major cause for facial fractures commonly encountered by maxillofacial surgeons. Mandible is commonly involved in facial trauma resulting in an isolated fracture or associated with other facial bones due to its prominent location in the facial skeleton. This study was undertaken to investigate the quality of life (QoL) post-operatively in patients diagnosed with undisplaced parasymphysis fracture who underwent open reduction and internal fixation (ORIF) under local anesthesia (LA) using the twin mix (TM) solution. Patients and Methods: A prospective randomized clinical study was conducted among 40 patients aged between 20-55 years requiring ORIF for unilateral vertically undisplaced parasymphysis fracture under LA. Group A patients (n = 20) received conventional LA solution with adrenaline, and Group B patients (n = 20) received freshly prepared TM solution for their surgical intervention as a day care procedure. Various parameters such as jaw function, ability to masticate and labialis activity (lower lip pout) were assessed. The data were collected and analyzed applying student's t test, Shapiro-Wilk test using SPSS software. Results: All the 20 patients in Group B who received TM solution exhibited better jaw function and mouth opening with a mean score of (±SD) of 4.55 (±0.944). They also exhibited reduced difficulty in mastication and ability to purse the lower lip on third post-operative day as compared to the patients in Group A. No complications were observed among the patients post-operatively in both the groups of this study. Conclusion: TM solution proves to be superior as compared to the conventional LA solution as the former offers an improved clinical outcomes enhancing the QoL post-operatively in patients undergoing ORIF for undisplaced parasymphysis mandibular fracture.

2.
J Stomatol Oral Maxillofac Surg ; 121(1): 2-8, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31255829

ABSTRACT

PURPOSE: The aim of this study was to investigate the feasibility of a custom made alloplastic Temporomandibular Joint (TMJ) device design in patients undergoing temporomandibular (TM) Total Joint Reconstruction (TJR). OBJECTIVE: TMJ disease with functional and anatomic distortion dictates the need for TJR. There are various materials to reconstruct a TMJ. However, various factors, such as cost, availability of prosthetic joint, limit its use to tertiary health care center. Hence, we have investigated the feasibility and efficacy of the custom made alloplastic TMJ prosthesis (DARSN TM Joint Prosthesis) with the advantage of being acceptable financially and the overall Quality of life (QoL) diagnosed with TMJ ankylosis and End Stage Joint Disease (ESJD) selected from the study population. MATERIALS AND METHODS: The study group comprised of 20 patients with TMJ ankylosis or End Stage Joint Disease (ESJD) who needed TM TJR of which few subjects in the study population had history of failed previous surgery to the TMJ region. The patients underwent resection of the joint followed by TJR using the custom made alloplastic TMJ prosthesis. Various subjective and objective variables were evaluated such as the Jaw Function (JF), Inter-incisal opening (IO), Diet intake (DI), Quality of Life (QoL) using a Psychometric Modified Likert Scale and nutritional status of the patient using the Mid-Upper Arm Circumference (MUAC) as reference. RESULTS: All the subjective and objective variables showed significant improvement in the postoperative period as compared to the preoperative period. The JF score increased with a mean score of 6.25 (P<0.00001). Postoperative mean DI score was 3.15 (P<0.00001) and IO increased up to 29-38mm in 95% of the study population. The study population exhibited an improved overall QoL and nutritional status post-operatively. Follow up period of 1 year showed significant functional improvement among the study population. CONCLUSION: The results shows that the custom made alloplastic joint replacement is safe and effective and reliable alternative to treat patients with TMJ disease which restricts the normal function to a greater degree requiring TM TJR.


Subject(s)
Joint Prosthesis , Quality of Life , Feasibility Studies , Humans , Prospective Studies , Temporomandibular Joint
3.
J Stomatol Oral Maxillofac Surg ; 121(3): 248-253, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31336212

ABSTRACT

INTRODUCTION: Intra-space drug administration have recently gained popularity in the clinical practice posing several advantages over the conventional routes of drug administration. A preliminary prospective randomized triple blind clinical study was conducted to compare the latency and duration of anesthesia with twin mix (1.8ml 2% lignocaine with 1:200,000 epinephrine and 1ml/4mg dexamethasone) and modified twin mix (1.7ml of 4% articaine with 1:100,000 epinephrine and 1ml/4mg dexamethasone) to two conventional local anesthesia solutions along with co-relation of clinical effects in the postoperative phase in patients undergoing extraction of impacted mandibular third molars in terms of patients comfort post-surgery. MATERIALS AND METHODS: The study was conducted among 20 patients with bilateral impacted mandibular third molars who were randomly allotted to two groups, Group A and B. Each patients in both the groups was allotted with study and control site. Among Group A, patients were further divided into Sub-group L (Control) and Sub-group TM (Twin Mix). Group B patients were divided as Sub-group A (Control) and sub-group MTM (Modified Twin Mix). Sub-group L patients received 1.8ml of 2% lignocaine with 1:200,000 adrenaline and sub-group TM received twin mix. Sub-group A received 1.7ml of 4% articaine with 1:100,000 adrenaline and sub-group MTM received modified twin mix solution. All the procedure was performed by a single operator with a gap of 1 month between the two interventions among both the groups. Various subjective and objective parameters were measured pre-operatively and postoperatively to assess the latency and efficacy of various anesthesia solutions used in this study for third molar removal. RESULTS: Mean (±SD) VAS scores for sting on injection and pain were found to be less in TM and MTM sub-group with a score of 2.3 (±0.768) and 2.7 (±0.065) respectively. The anesthetic latency was significantly less in sub-group TM, with a mean (±SD) of 52.4 (±28.3) seconds. Sub-groups A and MTM had longer latency of anesthesia when compared with L and TM sub-groups. The duration of soft tissue anesthesia was maximum in sub-group MTM as compared to the other sub-groups. Patients from control sub-groups among both the groups had increased swelling, post-surgical pain and trismus postoperatively. DISCUSSION: Intra-space administration of twin mix and modified twin mix is clinically efficacious in impacted mandibular third molars surgery with better clinical outcomes postoperatively. We observed one significant difference between TM and MTM that the latter solution provided a prolonged duration of anesthesia increasing the patient's comfort postoperatively after surgical removal of mandibular third molars.


Subject(s)
Molar, Third/surgery , Tooth, Impacted/surgery , Double-Blind Method , Humans , Prospective Studies , Tooth Extraction
4.
J Stomatol Oral Maxillofac Surg ; 120(6): 517-522, 2019 Dec.
Article in English | MEDLINE | ID: mdl-30965154

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the strain and stress distribution for DARSN alloplastic unilateral temporomandibular joint (TMJ) prosthesis and the effects on contralateral natural joint using a finite element analysis (FEA). METHODS: The replacement of the TMJ may have complications like infection, failure of hardware, facial paralysis and perforation. The understanding of the mechanical forces exerted by muscles of mastication and jaw movement on the joint helps in identifying the regions on alloplastic TMJ with various maximum forces, which makes that area more prone for failure of hardware. A three dimensional structural FEA was applied using a validated finite element model (FEM) where the areas of stress and strain were evaluated in the alloplastic joint and the contralateral natural joint. As the pattern of stress and strain can be influenced by the materials used for alloplastic joint and geometry of the design, mechanical property of bone and the attached musculature were also considered while construction the FEM analysis. RESULTS: The forces of the muscles of mastication has a vital role on the amount of stress and strain present across the alloplastic joint. Masseter and temporalis exhibited the greatest resultant force on the alloplastic as well as the natural condyle with a magnitude of 272 N and 329 N. This study assessed the maximum stress and strain on the condyle-ramus unit and fossa. CONCLUSION: FEA shows that alloplastic DARSN TMJ prosthesis distributes stress and strain equally between the alloplastic joint site and the contralateral natural joint causing minimal adverse effects to the natural joint. FEA also evaluated the stress and strain on alloplastic component and resulted in drawing clinical implications for operating surgical team.


Subject(s)
Arthroplasty, Replacement , Biomechanical Phenomena , Finite Element Analysis , Prosthesis Design , Temporomandibular Joint
5.
J Maxillofac Oral Surg ; 12(2): 237-9, 2013 Jun.
Article in English | MEDLINE | ID: mdl-24431847

ABSTRACT

The loss of teeth and their replacement by artificial denture is associated with many problems. Pre-prosthetic surgical procedures are performed to provide a better anatomic environment and to create proper supporting structures for construction of dentures. Whenever inadequate vestibular depth is present in edentulous mouth, deepening of vestibule is considered to increase the retention and stability of denture. Deepening of vestibule without any addition of the bone is termed as vestibuloplasty. This article describes the ease and convenience of vestibuloplasty followed by the use of Bhawsar-Karandikar stent to maintain the soft tissue modifications. The study yielded promising results and patient acceptance.