1.
Ann Med ; 55(2): 2270502, 2023.
Article in English | MEDLINE | ID: mdl-37857359

ABSTRACT

The study aimed to develop a sensitive and high-throughput liquid chromatography coupled with tandem mass spectrometry method to quantify concentrations of tramadol and paracetamol simultaneously in human plasma. Sample preparation involved single-step protein precipitation using methanol and two deuterated internal standards, tramadol D6 and paracetamol D4. Agilent Poroshell 120 EC-C18 (100 × 2.1 mm, 2.1 µm) analytical column was employed to achieve chromatographic separation. Detection was in positive ion multiple reaction monitoring mode. A tailing factor (Tf) of <1.2, separation factor (K prime) of >1.5 from the column dead time and signal-to-noise (S/N) ratio >10, were obtained for analytes and internal standards. The standard curve was linear over the concentration range of 2.5-500.00 ng/mL for tramadol and 0.025-20.00 µg/mL for paracetamol. A small injection volume of 1 µL, low flow rate of 440 µL/min and short analysis time of 3.5 min reduced the solvent consumption, analysis cost and system contamination. The results of method validation parameters fulfilled the acceptance criteria of bioanalytical guidelines. The method was successfully applied to a bioequivalence study of fixed-dose combination products of tramadol and paracetamol in Malaysian healthy subjects.


Subject(s)
Tramadol , Humans , Chromatography, Liquid , Tramadol/chemistry , Tandem Mass Spectrometry/methods , Acetaminophen , Chromatography, High Pressure Liquid/methods , Therapeutic Equivalency
2.
Molecules ; 27(17)2022 Sep 04.
Article in English | MEDLINE | ID: mdl-36080473

ABSTRACT

Etoricoxib is a non-steroidal anti-inflammatory drug (NSAID) used to treat pain and inflammation. The objective of the current study was to develop a sensitive, fast and high-throughput HPLC-ESI-MS/MS method to measure etoricoxib levels in human plasma using a one-step methanol protein precipitation technique. A tandem mass spectrometer equipped with an electrospray ionization (ESI) source operated in a positive mode and multiple reaction monitoring (MRM) were used for data collection. The quantitative MRM transition ions were m/z 359.15 > 279.10 and m/z 363.10 > 282.10 for etoricoxib and IS. The linear range was from 10.00 to 4000.39 ng/mL and the validation parameters were within the acceptance limits of the European Medicine Agency (EMA) and Food and Drug Analysis (FDA) guidelines. The present method was sensitive (10.00 ng/mL with S/N > 40), simple, selective (K prime > 2), and fast (short run time of 2 min), with negligible matrix effect and consistent recovery, suitable for high throughput analysis. The method was used to quantitate etoricoxib plasma concentrations in a bioequivalence study of two 120 mg etoricoxib formulations. Incurred sample reanalysis results further supported that the method was robust and reproducible.


Subject(s)
Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry , Chromatography, High Pressure Liquid/methods , Etoricoxib , Humans , Reproducibility of Results , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Therapeutic Equivalency
3.
Article in English | MEDLINE | ID: mdl-32905988

ABSTRACT

A simple, rapid, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method was developed to determine sitagliptin in human plasma. Diphenhydramine HCl was used as internal standard (IS). The chromatographic separation was achieved using Agilent Poroshell 120 EC-C18 - Fast LC column (100 × 2.1mmID, 2.7) fitted with UHPLC Guard Poroshell 120 EC-C18 (5 × 2.1mmID, 2.7 µm). The mobile phase consisted of 0.1% v/v formic acid and methanol (45:55, v/v) run at a flow rate of 0.45 mL/min at 30 °C. Methanol produced relatively cleaner plasma sample as deproteinization agent. Polytetrafluoroethylene membrane was preferred over nylon membrane as the former produced clear plasma samples. The standard calibration curve was linear over the concentration range of 5-500.03 ng/mL. The within-run precision was 0.53-7.12% and accuracy 87.09-105.05%. The between-run precision was 4.74-11.68% and accuracy 95.02-97.36%. The extended run precision was 3.60-6.88% and accuracy 93.18-95.82%. The recovery of analyte and IS was consistent. Sitagliptin in plasma was stable at benchtop (short term) for 24 h, in autosampler tray for 48 h, in instrumentation room for 48 h (post-preparative), after 7 freeze-thaw cycles (-20 ± 10 °C), and 62 days in the freezer (-20 ± 10 °C). Both sitagliptin (analyte) and IS stock solutions were stable for 62 days when kept at room temperature (25 ± 4 °C) and in chiller (2-8 °C). The validated method was successfully applied to a bioequivalence study of two sitagliptin formulations involving 26 healthy Malaysian volunteers.


Subject(s)
Chromatography, High Pressure Liquid/methods , Sitagliptin Phosphate/blood , Sitagliptin Phosphate/pharmacokinetics , Tandem Mass Spectrometry/methods , Adolescent , Adult , Humans , Limit of Detection , Linear Models , Male , Middle Aged , Reproducibility of Results , Sitagliptin Phosphate/chemistry , Therapeutic Equivalency , Young Adult