Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Plast Reconstr Surg ; 145(5): 1173-1181, 2020 05.
Article in English | MEDLINE | ID: mdl-32332535

ABSTRACT

BACKGROUND: This study is the first to correlate sonographic findings of subcutaneous tissue to structural and biomechanical properties. METHODS: Precisely sized tissue specimens (59 samples) were collected from five abdominoplasty procedures. A Philips Lumify L12-4 linear array probe, connected to an Android tablet, was used to obtain ultrasound images of the superficial fascial system. A no. 1 Vicryl suture on a CTX needle placed though a needle guide within a three-dimensionally printed template ensured equal bites of subcutaneous tissue across specimens. Suture pull-out strength was measured until failure at a displacement rate of 2.12 mm/second using an Admet MTEST Quattro. Mean gray value for the superficial fascial system in associated ultrasonographic images was quantified by CellProfiler. RESULTS: Superficial fascial system visualization can be accomplished using high-resolution portable ultrasound. Comparing multiple specimens' imaging, interpatient and intrapatient variability of superficial fascial system quantity and structural characteristics are apparent. The superficial fascial system is highly abundant in some patients, but has limited presence in others. Individual-specimen mean gray value and whole-patient mean gray value positively correlated with tissue tensile strength (p = 0.006) and patient-average tissue tensile strength (p = 0.036), respectively. Whole-patient mean gray value accounted for 98.5 percent of the variance seen in patient-average tensile strength, making it a strong predictor for tensile strength. CONCLUSIONS: Portable ultrasound and image-processing technology can visualize, quantify, and predict subcutaneous tissue strength of the superficial fascial system. The superficial fascial system quantity correlates with suture tensile strength. Clinically, preoperative superficial fascial system quantification may aid in outcome predictions, manage patient expectations, and potentially lower complication rates. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, V.


Subject(s)
Abdominal Wall/physiology , Image Processing, Computer-Assisted , Subcutaneous Tissue/diagnostic imaging , Abdominal Wall/surgery , Abdominoplasty/adverse effects , Abdominoplasty/methods , Biomechanical Phenomena/physiology , Humans , Postoperative Complications/etiology , Postoperative Complications/prevention & control , Preoperative Care/methods , Suture Techniques/adverse effects , Tensile Strength/physiology , Ultrasonography
2.
Ann Plast Surg ; 84(6S Suppl 5): S401-S404, 2020 06.
Article in English | MEDLINE | ID: mdl-32032109

ABSTRACT

BACKGROUND: The demand for body contouring surgery continues to rise. The inclusion of the superficial fascial system (SFS) during closure of such procedures has been shown to improve outcomes; however, currently reported wound complication rates remain high. The authors assess whether decreased quantities of SFS are associated with wound complications in these patients. METHODS: A retrospective study of patients undergoing body contouring surgery was performed. Preoperatively, ultrasound images were obtained of the SFS. Using Cellprofiler, the mean gray values (MGVs) of the SFS were calculated to quantify this structure. Chart review was performed to identify postoperative wound complications. RESULTS: Thirty-six patients were included: 30 abdominoplasties, 3 bilateral medial thigh lifts, and 3 bilateral brachioplasties. The overall wound complication rate was 22.5%. There were no significant differences in body mass index, age, smoking status, weight of resected specimen, or diabetes when comparing the complication and noncomplication groups. However, the MGV was significantly greater in the noncomplication group compared with the complication group (0.135 ± 0.008 vs 0.099 ± 0.005, respectively, P = 0.03). The average MGV for the entire cohort was 0.127. Patients with an MGV of greater than 0.127 had a wound complication rate of 0% compared with that of 39% for patients with an MGV of 0.127 or less (P = 0.005). CONCLUSIONS: Poor quantities of SFS identified by ultrasound were associated with increased wound complications in patients undergoing body contouring surgery. Furthermore, patients with better than average SFS seem to be protected from such complications.


Subject(s)
Abdominoplasty , Body Contouring , Humans , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Preoperative Care , Retrospective Studies , Thigh/surgery
3.
Ann Plast Surg ; 78(6S Suppl 5): S305-S310, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28328629

ABSTRACT

INTRODUCTION: The medial thighplasty is a procedure where patients may attain superior mobility, hygiene, and cosmesis. Most surgeons use attachment of the superficial fascial system (SFS) of the thigh flap to the Colles fascia, whereas others attach the SFS to the pubic ramus periosteum. Because of a high complication profile, we aim to elucidate the clinical, biomechanical, and anatomic qualities of the Colles fascia versus the pubic ramus periosteum. MATERIALS AND METHODS: We performed a 17-year retrospective review documenting clinical complications, a biomechanical analysis of sutures placed in different tissue layers of the thigh, and a histologic analysis surrounding the ischiopubic ramus. Separate suture pull-out strength testing was conducted on cadaveric tissue using an Admet MTEST Quattro with no. 1 Vicryl suture and tissue grips at a displacement rate of 2.12 mm/s. Simultaneous displacement and force were acquired at 100 Hz and with measurements obtained at regular intervals between the pubic symphysis and the ischial tuberosity in both the Colles fascia and the deeper periosteal layers of the thigh. A histologic analysis was performed at 3 points along the ischiopubic ramus using paraffin-embedded large mount tissue sections stained with hematoxylin, eosin, and Gomori trichrome. RESULTS: Thirty-nine patients underwent medial thighplasty with a 46.16% complication rate. Suture pull-out force of the suspected superficial Colles fascia sites was, on average, 72.8% less than values from the deeper periosteum tissue. Anchor points in the Colles fascia elongated 17.4% further before failure than those in the periosteum. There was noticeable variability between anchor points and across samples. The histologic sections suggest that the Colles fascia from the different regions of the ischiopubic ramus varies considerably in both continuity and collagen fiber content with no discernible pattern. The periosteal and muscular fascial layers were more continuous histologically with direct attachments into the pubis and ischium. CONCLUSIONS: Anchoring of the SFS to the periosteum did not improve our complication profile when compared with the literature. Both the biomechanical and histologic analyses demonstrate that the Colles fascia is highly variable in organizations with coincident variability in tissue strength. Our results require further study to identify the optimal surgical technique for medial thighplasty.


Subject(s)
Fasciotomy/methods , Periosteum/surgery , Surgery, Plastic/methods , Surgical Flaps/blood supply , Surgical Flaps/transplantation , Thigh/surgery , Adult , Biomechanical Phenomena , Cadaver , Cohort Studies , Female , Humans , Male , Middle Aged , Periosteum/transplantation , Pubic Bone/surgery , Retrospective Studies , Suture Anchors , Suture Techniques , Thigh/anatomy & histology , Treatment Outcome
4.
Surg J (N Y) ; 2(4): e126-e130, 2016 Oct.
Article in English | MEDLINE | ID: mdl-28825005

ABSTRACT

A localized, intermittent muscle-cooling protocol was implemented to determine cooling garment efficacy in reducing upper extremity muscular fatigue and tremor in novice ( n = 10) and experienced surgeons ( n = 9). Subjects wore a muscle-cooling garment while performing multiple trials of a forearm exercise and paired suturing task to induce muscular fatigue and exercise-induced tremor. A reduction in tremor amplitude and an extension in time to fatigue were expected with muscle cooling as compared with control trials. Each subject completed an intervention session (5°C cooling condition) and a control session (32°C or thermal neutral condition). A paired samples t test indicated that tremor amplitude was significantly reduced ( t [8] = 1.89458; p < 0.05) in experienced surgeons in two dimensions (up and down, and back and forth). Tremor amplitude was reduced in novice surgeons but the effect was not significant. Time to fatigue and suture time improved in both cohorts with muscle cooling, but the effect did not reach significance. Results from the pilot work suggest muscle cooling as an intervention for reduction of fatigue and tremor is very promising, warranting further investigation. Surgical specialties that require prolonged procedures might benefit more from this intervention.

SELECTION OF CITATIONS
SEARCH DETAIL
...