Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Arch Virol ; 165(12): 2973-2977, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32886215

ABSTRACT

The bacteriophage vB_AhM_PVN02 (PVN02), infecting Aeromonas hydrophila, was isolated from a striped catfish pond water sample in Can Tho City, Vietnam. The phage had high lytic activity with a latent period and burst size of approximately 20 min and 105 plaque-forming units per cell, respectively. Observation of the phage by transmission electron microscopy indicated that PVN02 belongs to the family Myoviridae. The genome of PVN02 is a double-stranded linear DNA with a length in 51,668 bp and a content of 52% GC. Among the 64 genes, 16 were predicted to encode proteins with predicted functions. No virulence or antibiotic resistance genes were found in the genome, suggesting it would be a useful biocontrol agent. Classification of the phage based on sequence comparisons, phylogenetic analysis, and gene-sharing networks was carried out, and it was found to be the first representative of a new species within a previously undefined genus in the family Myoviridae. This study confirmed that PVN02 is a novel lytic phage that could potentially be used as an agent to control Aeromonas hydrophila in striped catfish in the Mekong Delta, Vietnam.


Subject(s)
Aeromonas hydrophila/virology , Catfishes/microbiology , Myoviridae/genetics , Phylogeny , Animals , Aquaculture , Fish Diseases/microbiology , Genomics , Vietnam , Whole Genome Sequencing
2.
Bioanalysis ; 6(15): 2071-82, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25322783

ABSTRACT

BACKGROUND: apixaban (BMS-562247) (Eliquis(®)) is a novel, orally active, selective, direct, reversible inhibitor of the coagulation factor Xa (FXa). A sensitive and reliable method was developed and validated for the measurement of apixaban (BMS-562247) and its major circulating metabolite (BMS-730823) in human citrated plasma for use in clinical testing. METHODOLOGY/RESULTS: A 0.100 ml portion of citrated plasma sample was extracted and analyzed by LC-MS/MS. Run times were approximately 3 min. The lower limit of quantification (LLOQ) was 1.00 ng/ml for BMS-562247 and 5.00 ng/ml for BMS-730823. Intra- and inter-assay precision values for replicate QC control samples were within ≤5.36% for both analytes (≤7.52% at the LLOQ). The accuracy for both analytes was within ±9.00%. CONCLUSION: The method was demonstrated to be sensitive, selective and robust, and was successfully used to support clinical studies.


Subject(s)
Chromatography, High Pressure Liquid/methods , Pyrazoles/blood , Pyridones/blood , Tandem Mass Spectrometry/methods , Chromatography, High Pressure Liquid/instrumentation , Factor Xa Inhibitors/blood , Humans
SELECTION OF CITATIONS
SEARCH DETAIL