Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
AJNR Am J Neuroradiol ; 43(8): E18, 2022 08.
Article in English | MEDLINE | ID: mdl-35863782
2.
AJNR Am J Neuroradiol ; 43(6): 872-880, 2022 06.
Article in English | MEDLINE | ID: mdl-35618421

ABSTRACT

BACKGROUND AND PURPOSE: We hypothesized that 3D T1-TSE "black-blood" images may carry an increased risk of contrast-enhancing lesion misdiagnosis in patients with MS because of the misinterpretation of intraparenchymal vein enhancement. Thus, the occurrence of true-positive and false-positive findings was compared between standard MPRAGE and volumetric interpolated brain examination techniques. MATERIALS AND METHODS: Sampling perfection with application-optimized contrasts by using different flip-angle evolution (SPACE) images obtained from 232 patients with MS, clinically isolated syndrome, or radiologically isolated syndrome were compared with standard MPRAGE and volumetric interpolated brain examination images. The intraparenchymal vein contrast-to-noise ratio was estimated at the level of the thalami. Contrast-enhancing lesions were blindly detected by 2 expert readers and 1 beginner reader. True- and false-positives were determined by senior readers' consensus. True-positive and false-positive frequency differences and patient-level diagnosis probability were tested with the McNemar test and OR. The contrast-to-noise ratio and morphology were compared using the Mann-Whitney U and χ2 tests. RESULTS: The intraparenchymal vein contrast-to-noise ratio was higher in SPACE than in MPRAGE and volumetric interpolated brain examination images (P < .001, both). There were 66 true-positives and 74 false-positives overall. SPACE detected more true-positive and false-positive results (P range < .001-.07) but did not increase the patient's true-positive likelihood (OR = 1 1.29, P = .478-1). However, the false-positive likelihood was increased (OR = 3.03-3.55, P = .008-.027). Venous-origin false-positives (n = 59) with contrast-to-noise ratio and morphology features similar to small-sized (≤14 mm3 P = .544) true-positives occurred more frequently in SPACE images (P < .001). CONCLUSIONS: Small intraparenchymal veins may confound the diagnosis of enhancing lesions on postgadolinium black-blood SPACE images.


Subject(s)
Multiple Sclerosis , Brain/diagnostic imaging , Brain/pathology , Contrast Media , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Multiple Sclerosis/diagnostic imaging , Multiple Sclerosis/pathology
3.
AJNR Am J Neuroradiol ; 43(2): 216-222, 2022 02.
Article in English | MEDLINE | ID: mdl-34969667

ABSTRACT

BACKGROUND AND PURPOSE: Ischemic stroke can be mimicked by nonischemic conditions. Due to emphasis on the rapid treatment of acute ischemic stroke, it is crucial to identify these conditions to avoid unnecessary therapies and potential complications. We investigated the performance of the multimodal CT protocol (unenhanced brain CT, CTA, and CTP) to discriminate stroke mimics from acute ischemic stroke. MATERIALS AND METHODS: We retrospectively selected multimodal CT studies performed for clinical suspicion of acute ischemic stroke in our center in a 24-month period, including patients with at least 1 follow-up imaging study (brain CT or MR imaging). Hemorrhagic strokes were excluded. We measured the performance of multimodal CT, comparing the original diagnostic results with the final clinical diagnosis at discharge. RESULTS: Among 401 patients, a stroke mimic condition was diagnosed in 89 (22%), including seizures (34.8%), migraine with aura attack (12.4%), conversion disorder (12.4%), infection (7.9%), brain tumor (7.9%), acute metabolic condition (6.7%), peripheral vertigo (5.6%), syncope (5.6%), transient global amnesia (3.4%), subdural hematoma (1.1%), cervical epidural hematoma (1.1%), and dural AVF (1.1%). Multimodal CT sensitivity, specificity, and accuracy were 24.7%, 99.7%, and 83%. Multimodal CT revealed peri-ictal changes in 13/31 seizures and diagnosed 7/7 brain tumors, 1/1 dural AVF, and 1/1 subdural hematoma. CT perfusion played a pivotal diagnostic role. CONCLUSIONS: Multimodal CT demonstrated low sensitivity but high specificity in the diagnosis of stroke mimics in the acute setting. The high specificity of multimodal CT allows ruling out stroke and thereby avoiding unnecessary revascularization treatment in patients with diagnosis of a stroke mimic.


Subject(s)
Brain Ischemia , Ischemic Stroke , Brain Ischemia/therapy , Humans , Magnetic Resonance Imaging , Retrospective Studies , Tomography, X-Ray Computed/methods
4.
AJNR Am J Neuroradiol ; 40(7): 1140-1148, 2019 07.
Article in English | MEDLINE | ID: mdl-31221635

ABSTRACT

BACKGROUND AND PURPOSE: Postgadolinium MR imaging is crucial for brain tumor diagnosis and morphometric assessment. We compared brain tumor enhancement visualization and the "target" object morphometry obtained with the most commonly used 3D MR imaging technique, MPRAGE, with 2 other routinely available techniques: sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) and volumetric interpolated brain examination (VIBE). MATERIALS AND METHODS: Fifty-four contrast-enhancing tumors (38 gliomas and 16 metastases) were assessed using MPRAGE, VIBE, and SPACE techniques randomly acquired after gadolinium-based contrast agent administration on a 3T scanner. Enhancement conspicuity was assessed quantitatively by calculating the contrast rate and contrast-to-noise ratio, and qualitatively, by consensus visual comparative ratings. The total enhancing tumor volume and between-sequence discrepancy in the margin delineation were assessed on the corresponding 3D target objects contoured with a computer-assisted software for neuronavigation. The Wilcoxon signed rank and Pearson χ2 nonparametric tests were used to investigate between-sequence discrepancies in the contrast rate, contrast-to-noise ratio, visual conspicuity ratings, tumor volume, and margin delineation estimates. Differences were also tested for 1D (Response Evaluation Criteria in Solid Tumors) and 2D (Response Assessment in Neuro-Oncology) measurements. RESULTS: Compared with MPRAGE, both SPACE and VIBE obtained higher contrast rate, contrast-to-noise ratio, and visual conspicuity ratings in both gliomas and metastases (P range, <.001-.001). The between-sequence 3D target object margin discrepancy ranged between 3% and 19.9% of lesion tumor volume. Larger tumor volumes, 1D and 2D measurements were obtained with SPACE (P range, <.01-.007). CONCLUSIONS: Superior conspicuity for brain tumor enhancement can be achieved using SPACE and VIBE techniques, compared with MPRAGE. Discrepancies were also detected when assessing target object size and morphology, with SPACE providing more accurate estimates.


Subject(s)
Brain Neoplasms/diagnostic imaging , Glioma/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Neuroimaging/methods , Adult , Aged , Brain Neoplasms/pathology , Contrast Media , Female , Glioma/pathology , Humans , Imaging, Three-Dimensional/methods , Male , Middle Aged
5.
Diagn Interv Imaging ; 98(4): 307-314, 2017 Apr.
Article in English | MEDLINE | ID: mdl-27671861

ABSTRACT

PURPOSE: The purpose of this study was to define the feasibility, the efficacy and the safety of preoperative embolization (POE) of meningiomas using polyvinyl alcohol (PVA) particles. MATERIALS AND METHODS: Between January 2006 and June 2014, 191 consecutive patients were referred to our institution for the treatment of meningiomas; of these 57 patients were excluded from the study. A total of 64 patients (22 men and 42 women) with a mean age of 58.4±10.8 [SD] years (range: 14-82years) who underwent POE with PVA particles, achieving extensive (>90%) devascularization were ultimately included and compared to 70 patients who had surgery without POE. Surgical time and intraoperative blood loss were compared between the two groups. The duration of procedures and complications related to POE were analyzed. RESULTS: No differences were found between the two groups with respect to intraoperative blood loss. A significant reduction in surgical time was observed for the group who had POE (207.4±79.5 [SD] min vs. 226.9±117.6 [SD] min; P=0.028). In a subgroup analysis, the size and location of meningiomas did not influence these results. The duration of procedures was 41.4±10.5 [SD] min. Minor complications related to POE occurred in 3 out of 64 patients (4.7%). CONCLUSION: POE of meningiomas using PVA particles is effective in reducing surgical time, when extensive tumor devascularization is achieved. However, radiation exposure, the duration of procedures and complications related to POE with PVA particles do not justify this technique in most patients.


Subject(s)
Embolization, Therapeutic , Meningeal Neoplasms/surgery , Meningioma/surgery , Neoadjuvant Therapy , Preoperative Care , Adolescent , Adult , Aged , Aged, 80 and over , Blood Loss, Surgical/physiopathology , Combined Modality Therapy , Feasibility Studies , Female , Humans , Male , Meningeal Neoplasms/blood supply , Meningioma/blood supply , Middle Aged , Operative Time , Polyvinyl Alcohol , Young Adult
6.
Acta Otorhinolaryngol Ital ; 35(5): 314-20, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26824912

ABSTRACT

Our aim was to define typical magnetic resonance (MRI) findings in malignant and benign parotid tumours. This study is based on retrospective evaluation of pre-surgical MRI of 94 patients with parotid gland tumours. Histology results were available for all tumours. There were 69 cases of benign (73%) and 25 cases of malignant (27%) tumours, including 44 pleomorphic adenomas, 18 Warthin's tumours, 7 various benign tumours, 6 squamous cell carcinomas, 3 carcinoma ex pleomorphic adenomas, 2 mucoepidermoid carcinomas, 1 adenoid cystic carcinoma and 13 various malignant tumours. The following MRI parameters were evaluated: shape, site, size, margins, signal intensity (SI) on T1w and T2w images, contrast enhancement, signal of cystic content, presence or absence of a capsule, perineural spread, extraglandular growth pattern and cervical adenopathy. Statistical analysis was performed to identify the MRI findings most suggestive of malignancy, and to define the most typical MRI pattern of the most common histologies. Ill-defined margins (p < 0.001), adenopathies (p < 0.001) and infiltrative grown pattern (p < 0.001) were significantly predictive of malignancy. Typical findings of pleomorphic adenoma included hyperintensity on T2w images (p = 0.02), strong contrast enhancement (p < 0.001) and lobulated shape (p = 0.04). Typical findings of Warthin's tumour included hyperintense components on T1w images (p < 0.001), location in the parotid inferior process (p < 0.001) and mild or incomplete contrast enhancement (p = 0.01). SI on T1w and T2w images and contrast enhancement enables differential diagnosis between pleomorphic adenoma and Warthin's tumour.


Subject(s)
Magnetic Resonance Imaging , Parotid Neoplasms/diagnosis , Adenolymphoma/diagnosis , Adenoma, Pleomorphic/diagnosis , Diagnosis, Differential , Humans , Magnetic Resonance Spectroscopy , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...