Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
J Dent ; 112: 103745, 2021 09.
Article in English | MEDLINE | ID: mdl-34252489

ABSTRACT

OBJECTIVES: To compare the effect of 5 desensitizing agents on the hydraulic conductance (Lp) of dentin and to analyze its surface under a Laser Scanning Confocal Microscope (LSCM) before and after an erosive challenge. METHODS: Lp was analyzed in the following sequence: in the presence of smear layer (pMin), after a 15-second acid etching (pMax), after treatment with a desensitizing agent (pTreat) and after a 1-minute erosive challenge (6% citric acid - pEro). Fifty 1.0 ± 0.2 mm-thick dentin disks were prepared from sound human third molars and were randomly distributed into 5 groups (n = 10): FG-Fluoride gel (control), SA-Sensiactive, PR-Sensitive Pro-Relief, NP-Desensibilize Nano-P and EV-Enamel Pro Varnish. Data were analyzed by two-way ANOVA and Tukey tests (α<0.05). Additional specimens were analyzed under a Laser Scanning Confocal Microscope (LSCM) and by Energy Dispersive X-ray Spectroscopy (EDS). RESULTS: All materials reduced the Lp in some extent, except for FG and EV. After the erosive challenge, SA was the only material effectively able to keep the same Lp of the post-treatment phase, while the other products showed lower resistance upon an erosive challenge. Under the LSCM, the SA and NP materials were more effective to obliterate the opened dentin tubules and demonstrated higher resistance upon an erosive challenge. The EDS analysis evidenced levels of Ca, O, P, Si, Na and S. CONCLUSIONS: Product containing potassium oxalate was the most effective in reducing Lp of dentin samples before and after an erosive challenge. Under a LSCM, products containing potassium oxalate or hydroxyapatite crystals seemed to be occluding the dentin tubules after an erosive challenge.


Subject(s)
Dentin Desensitizing Agents , Dentin Sensitivity , Dentin , Dentin Desensitizing Agents/pharmacology , Dentin Desensitizing Agents/therapeutic use , Dentin Permeability , Dentin Sensitivity/drug therapy , Humans , Microscopy, Electron, Scanning
2.
Bauru; s.n; 2011. 117 p. ilus, tab, graf.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-865806

ABSTRACT

O tratamento das lesões cervicais não cariosas hipersensíveis com agentes dessensibilizantes pode ser uma opção prática e eficaz devido, principalmente, à capacidade desses produtos de obliterarem os túbulos dentinários expostos. Portanto, o objetivo deste estudo foi analisar, in vitro, o efeito quantitativo e qualitativo de cinco agentes dessensibilizantes em relação ao seu potencial de obstrução dos túbulos dentinários. Para a análise quantitativa, foram utilizados testes de condutividade hidráulica da dentina em diferentes condições experimentais. Os ensaios foram realizados na seguinte sequência experimental: na presença de smear layer (PMin); após condicionamento com ácido fosfórico a 37%, por 15 segundos (PMax); após a aplicação dos agentes dessensibilizantes e após o desafio com ácido cítrico a 6%, por um minuto. Para isso, foram selecionados 50 terceiros molares humanos hígidos não irrompidos, a partir dos quais foram confeccionados discos de dentina com espessura de 0,80 ± 1,00 mm e divididos em 5 grupos (n=10) de acordo com os diferentes agentes dessensibilizantes: Grupo 1 (Sensiactive); Grupo 2 (Sensitive Pro-Alívio); Grupo 3 (Flúor gel);Grupo 4 (Desensibilize Nano-P); e Grupo 5 (Enamel Pro@ Varnish). As medidas de condutividade hidráulica dentinária (Lp) foram analisadas através do teste ANOVA a dois critérios (p<0,05) para se determinar as diferenças intra e intergrupos. As diferenças individuais foram determinadas pelo teste Tukey, também a um nível de significância de 5%. Já a análise qualitativa foi realizada através da observação de imagens feitas através do microscópio confocal a laser (MCL). Nesse caso, foram selecionados 18 terceiros molares humanos hígidos não irrompidos, sendo que a preparação e armazenamento dos discos para as condições experimentais seguiram os mesmos passos descritos para os experimentos de condutividade hidráulica. Os espécimes foram divididos em 6 grupos, n=3, conforme os materiais experimentais estudados, e os...


The treatment of hypersensitive non carious cervical lesions with desensitizing agents may be a practical and effective alternative, mainly due to the ability of these products to obliterate the exposed dentinal tubules. Therefore, the aim of this study was to investigate, in vitro, the quantitative and qualitative effect of five desensitizing agents in relation to their ability to obstruct dentinal tubules. The quantitative analysis was based on dentin hydraulic conductance tests achieved under different experimental conditions. The tests were performed in the following experimental sequence: in the presence of smear layer (PMin); after a 15-second acid etching (37% phosphoric acid- PMax); after the application of the desensitizing agents; and after a 1-minute acid challenge (6% citric acid). Fifty sound not erupted extracted human third molars were randomly selected and, from them, 0.08±1.00 mm-thickness dentine discs were obtained for distribution into 5 groups (n=10), according to the different desensitizing agents: Group 1 (Sensiactive); Group 2 (Sensitive Pro-Relief); Group 3 (Fluoride gel); Group 4 (Desensibilize Nano-P) and Group 5 (Enamel Pro@ Varnish). Dentin hydraulic conductance measures (Lp) were analyzed by two-way ANOVA (p<0.05) to determine intra and intergroup differences. Individual differences were determined by Tukey test, also at a significance level of 5%. The qualitative analysis was performed by observing images obtained from specimens via laser scanning confocal microscopy (LSCM). Here, 18 sound not erupted extracted human third molars were randomly selected and specimens preparation and storage for each experimental condition followed the same steps described for the experiments regarding dentin hydraulic conductance tests. Specimens were divided into 6 groups (n=3), according to studied materials, and each dentin disc was dimidiate to allow performing of the two phases of the experiment on the same disk. A group of...


Subject(s)
Humans , Dentin Desensitizing Agents/pharmacology , Tooth Cervix , Dentin , Tooth Permeability , Dentin Sensitivity/drug therapy , Acid Etching, Dental , Analysis of Variance , Dentin/chemistry , In Vitro Techniques , Smear Layer , Time Factors
3.
Rev. fac. odontol. Univ. Fed. Bahia ; 37: 63-67, jul.-dez. 2008. ilus
Article in Portuguese | BBO - Dentistry | ID: biblio-858103

ABSTRACT

Diversos tipos de tratamentos de superfície são propostos para melhorar a adesão entre metal e resina. Entre eles, destacam-se o micromecânico, macromecânico, químico, sinalização e a associação de métodos. A melhor força de adesão entre as superfícies metálicas e resinosas contribui para o aumento da qualidade e longevidade da cimentação de prótese fixas adesivas, revestimentos estéticos de prótese metaloplásticas, próteses inferiores sobre implantes ósseointegrados e reparos de próteses antigas com revestimento estético fraturado. Apesar da existência de diversas técnicas, a literatura mostra que ainda persistem dúvidas sobre a retentividade das superfícies em questão e sobre o modo de aplicação. Dessa maneira o objetivo desse trabalho foi analisar a influència do silano na união metal-rsina, destacando suas propriedades físicas e químicas e os procedimentos técnicos de aplicação, a fim de contribuir para o esclarecimento das indicações clínicas e laboratoriais para cada tipo de associação dos diversos tipos de superfícies matálicas e resinosas


Subject(s)
Dental Materials , Metals , Resin Cements , Silanes
4.
Rev. fac. odontol. Univ. Fed. Bahia ; 36: 69-73, jan.-jun. 2008.
Article in Portuguese | BBO - Dentistry | ID: biblio-858090

ABSTRACT

A endodontia, ao longo da história, tem investigado métodos mais rápidos seguros e eficientes na preparação e limpeza dos condutos radiculares. O desenvolvimento de sistemas que utilizam o níquel e o titânio incorporou uma série de mudanças no preparo dos canais radiculares, uma vez que apresenta excelentes propriedades de flexibilidade, resistência à torção e memória quanto a sua forma em relação ao aço. Vários instrumentos rotatórios Ni-Ti têm sido desenvolvidos e sua habilidade de manter a forma do canal tem sido confirmada, com a vantagem adicional de obter um preparo mais eficiente do que o realizado pelas técnicas manuais. Recentemente, foi introduzido um novo grupo de instrumentos rotatórios endodônticos, o Sistema RaCe®(Reamer with Aternating Cutting Edges), com um desenho que torna capaz de preparar canais de forma mais segura, com pouco risco de desvios e perfurações, além de limpar e modelar os condutos efetivamente. O objetivo deste trabalho é apresentar uma revisão de literatura sobre o Sistema RaCe® mostrando suas características, indicações, assim como, os princípios da técnica utilizada pelos mesmos


Subject(s)
Dental Instruments , Root Canal Therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...