Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Publication year range
1.
ROBRAC ; 22(61)abr./jun.. ilus, tab
Article in Portuguese | LILACS | ID: lil-691759

ABSTRACT

Aim: The purpose of this study was to evaluate the bond strength of metallic crowns cemented to straight and angled customizable abutments with zinc phosphate. Material and Method: Thirty-nine external hex nalogs and abutments were divided in group S: customizable straight abutment (n = 10), group A17 with 17° angled abutment (n = 10) and group A30 with 30° angled abutment (n = 10) all cemented with zinc phosphate. The metal copings were cemented onto their corresponding metal dies according manufacture guidelines. Data from the all groups were compared with a 1-way ANOVA (?=.05) and Tukey's test. SEM evaluation were performed (n = 3) aiming to investigate microscopic features of the abutment-cement-crown interfaces. Results: The mean force (SD) required to dislodge the crowns in the S, A17 and A30 groups was 357.26 (62.21) N; 251.50 (20.13) N and 276.70 (17.96) N respectively. The Tukey test (p <0.05) revealed a significant statistically differences between the groups (p =.002) and the 17° angled abutment and 30° angled abutment group were statistically similar to each other and different from the group of straight abutments. Zinc phosphate showed an inhomogeneous cement line in SEM analysis. Conclusions: Within the limitations of this study, it can be conclude that the available surface area and convergence of the abutments axial walls of the straight abutments positively influenced bond strength in metallic crowns cemented with zinc phosphate.

2.
Int J Oral Maxillofac Implants ; 27(5): e86-9, 2012.
Article in English | MEDLINE | ID: mdl-23057047

ABSTRACT

In the past, the Branemark Novum protocol for the immediate functional loading of a mandibular fixed implant supported prosthesis provided an effective alternative for select patients. However, the manufacturer has discontinued this design, and only a few selected prosthetic-related replacement components are currently available. This clinical report presents the loss of an implant associated with a discontinued system. To take advantage of all of the preexisting components, it proposes a rescue procedure that allows continuous use of the original fixed restoration during the restoration of the tripod support at the implant level.


Subject(s)
Dental Prosthesis Design , Dental Prosthesis Repair/methods , Dental Prosthesis, Implant-Supported/instrumentation , Dental Restoration Failure , Device Removal/methods , Immediate Dental Implant Loading/instrumentation , Dental Prosthesis, Implant-Supported/methods , Humans , Immediate Dental Implant Loading/methods , Male , Mandible , Middle Aged , Retreatment/instrumentation , Retreatment/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...