Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
3.
Anesth Analg ; 61(1): 36-41, 1982 Jan.
Article in English | MEDLINE | ID: mdl-7198412

ABSTRACT

This study compares physical and behavioral characteristics of currently used cuffed tracheal tubes. Variability in physical and behavioral characteristics between size 8 tracheal tubes and cuffs exists: radius of tube curvature varies from 12.1 to 15.8 cm, bevel angle 39 to 56 degrees, bevel direction 73 to 107 degrees, distance from proximal end of bevel to cuff 15.4 to 24.4 mm, internal tube diameter 7.5 to 8.8 mm, wall thickness 1.14 to 2.37 mm, force to collapse 1020 to 3103 g, angle to kink 52 to 96 degrees, and indentation hardness 65.4 to 83.1. Cuff lengths vary from 29.7 to 45.3 mm, thickness 0.03 to 0.54 mm, diameter 14.5 to 32 mm, and cuff resting volume 0.15 to 19.9 ml. We recommend use of a soft, thermolabile, kink- and collapse-resistant tracheal tube fitted with a soft, thin-walled, tough, compliant, moderately long cuff, with a moderately large resting volume and diameter larger than tracheal diameter. Argyle, National Catheter, Ohio, Portex, Rusch "safety," and Shiley tracheal tubes resist collapse and kinking. Argyle, Lanz, National Catheter "hi-lo," National Catheter "intermediate hi-lo," Ohio, and Portex "profile" cuffs are thin and have diameters larger than the average male tracheal diameter.


Subject(s)
Intubation, Intratracheal/instrumentation , Hardness , Physical Phenomena , Physics , Pressure
4.
J Bone Joint Surg Am ; 60(4): 528-32, 1978 Jun.
Article in English | MEDLINE | ID: mdl-670276

ABSTRACT

The somatosensory evoked potential can be obtained in the anesthetized patient during corrective surgery on the spine. The techniques of anesthesia and somatosensory evoked potential recordings described herein were utilized in fifty-five patients during surgical correction of scoliosis with Harrington instrumentation and spine fusion. No detectable complications were encountered and no neurological morbidity ensued in our series. This method may prove to be of significant value when potential injury to the spinal cord may be encountered during correction of spinal deformities.


Subject(s)
Orthopedic Fixation Devices , Scoliosis/surgery , Somatosensory Cortex/physiology , Evoked Potentials , Humans , Neuromuscular Diseases/complications , Orthopedic Fixation Devices/adverse effects , Scoliosis/etiology , Spinal Cord Injuries/etiology , Spinal Cord Injuries/physiopathology , Spinal Fusion/adverse effects
5.
J Am Dent Assoc ; 96(1): 105-6, 1978 Jan.
Article in English | MEDLINE | ID: mdl-271160
SELECTION OF CITATIONS
SEARCH DETAIL
...