Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
J Am Heart Assoc ; : e033500, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38780185

ABSTRACT

BACKGROUND: Even after atrial fibrillation (AF) catheter ablation, many patients still experience relevant symptom burden. The objective of the MENTAL AF trial was to determine whether app-based mental training (MT) during the 3 months following pulmonary vein isolation reduces AF-related symptoms. METHODS AND RESULTS: Patients scheduled for pulmonary vein isolation were enrolled and randomized 1:1 to either app-based MT or usual care. Of 174 patients, 76 in the MT and 75 in the usual care group were included in the final analysis. The intervention was delivered by a daily 10-minute app-based MT. The primary outcome was the intergroup difference of the mean AF6 sum score, an AF-specific questionnaire, during the 3-month study period. Secondary outcomes included quality-of-life measures such as the AFEQT (Atrial Fibrillation Effect on Quality of Life). Mean age (SD) was 61 (8.7) years and 61 (41%) were women. The mean AF6 sum score over the study period was 8.9 (6.9) points in the MT group and 12.5 (10.1) in the usual care group (P=0.011). This referred to a reduction in the AF6 sum score compared with baseline of 75% in MT and 52% for usual care (P<0.001). The change in the AFEQT Global Score was 22.6 (16.3) and 15.7 (22.1), respectively; P=0.026. CONCLUSIONS: MENTAL AF showed that app-based MT as an adjunctive treatment tool following pulmonary vein isolation was feasible. App-based MT was found to be superior to standard care in reducing AF-related symptom burden and improving health-related quality of life. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04067427.

2.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38646922

ABSTRACT

AIMS: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning. METHODS AND RESULTS: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations. All patients received Ablation Index-guided HPSD ablation and subsequent oesophagogastroduodenoscopy. A machine learning algorithm categorized ablation points by atrial location and analysed ablation data, including Ablation Index, focusing on the posterior wall. The study is registered in clinicaltrials.gov (NCT05709756). Between February 2021 and August 2023, 238 patients were enrolled, of whom 18 (7.6%; nine oesophagus, eight vagus nerve, one both) developed thermal injuries, including eight oesophageal erythemata, two ulcers, and no fistula. Higher mean force (15.8 ± 3.9 g vs. 13.6 ± 3.9 g, P = 0.022), ablation point quantity (61.50 ± 20.45 vs. 48.16 ± 19.60, P = 0.007), and total and maximum Ablation Index (24 114 ± 8765 vs. 18 894 ± 7863, P = 0.008; 499 ± 95 vs. 473 ± 44, P = 0.04, respectively) at the posterior wall, but not oesophagus location, correlated significantly with thermal injury occurrence. Patients with thermal injuries had significantly lower distances between left atrium and oesophagus (3.0 ± 1.5 mm vs. 4.4 ± 2.1 mm, P = 0.012) and smaller atrial surface areas (24.9 ± 6.5 cm2 vs. 29.5 ± 7.5 cm2, P = 0.032). CONCLUSION: The low thermal lesion's rate (7.6%) during Ablation Index-guided HPSD ablation for atrial fibrillation is noteworthy. Machine learning based ablation data analysis identified several potential predictors of thermal injuries. The correlation between machine learning output and injury development suggests the potential for a clinical tool to enhance procedural safety.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Vagus Nerve Injuries , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/epidemiology , Male , Female , Esophagus/injuries , Esophagus/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Middle Aged , Vagus Nerve Injuries/etiology , Vagus Nerve Injuries/epidemiology , Incidence , Aged , Machine Learning , Risk Factors , Germany/epidemiology , Burns/epidemiology , Burns/etiology , Time Factors , Treatment Outcome , Pulmonary Veins/surgery , Vagus Nerve
3.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38582974

ABSTRACT

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Subject(s)
Cardiomyopathies , Catheter Ablation , Cryosurgery , Tachycardia, Ventricular , Aged , Humans , Middle Aged , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Cardiomyopathies/surgery , Catheter Ablation/adverse effects , Cicatrix/complications , Cryosurgery/adverse effects , Prospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Temperature , Treatment Outcome
4.
Sci Rep ; 14(1): 8974, 2024 04 18.
Article in English | MEDLINE | ID: mdl-38637577

ABSTRACT

Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations. nsWHcs succeeded in all patients (nominal scan duration, 98 ± 10 s); automatic segmentation/generation of surface meshes of right-sided cavities exhibited short computation times (16 ± 3 s) with correct delineation of right atrium, right ventricle, tricuspid annulus and coronary sinus ostium in 100%, 100%, 100% and 95%, respectively. Point-by-point ablation adhered to the predefined isthmus line in 62% of patients (26/42); activation mapping confirmed complete bidirectional isthmus block (conduction time difference, 136 ± 28 ms). nsWHcs ensured automatic and reliable 3D segmentation of targeted endoluminal cavities, multiplanar reformatting and image fusion (e.g. activation time measurements) and represented the basis for precise real-time active catheter navigation during EP-CMR ablations of isthmus-dependent right atrial flutter. Hence, nsWHcs can be considered a key component in order to advance EP-CMR towards the ultimate goal of targeted substrate-based ablation procedures.


Subject(s)
Atrial Flutter , Catheter Ablation , Humans , Atrial Flutter/diagnostic imaging , Atrial Flutter/surgery , Surgical Mesh , Catheter Ablation/methods , Heart Atria/diagnostic imaging , Heart Atria/surgery , Arrhythmias, Cardiac , Treatment Outcome
5.
Clin Cardiol ; 47(3): e24250, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38450791

ABSTRACT

BACKGROUND: Catheter ablation has become one of the main treatment strategies in patients with premature ventricular complexes (PVC). The successful mapping and ablation can be performed with an ablation catheter without additional diagnostic catheters. HYPOTHESIS: We hypothesize that using a single catheter for PVC ablation may decrease complications, procedure time, and fluoroscopy exposure while maintaining comparable success rates. METHODS: Sixty-nine consecutive patients with PVC were treated with a single catheter approach compared to a historical cohort, in which a conventional setup was used. Propensity score matching was conducted with a 1:1 ratio. Outcome parameters included acute procedural success with elimination of all premature ventricular contractions after catheter ablation, procedural data as well as complication rates. RESULTS: Patients treated with a single catheter approach had shorter total procedure (60 minutes [IQR: 47,5-69,0 minutes] vs. 90 minutes [IQR 60-120 minutes]; p = 0.001) and fluoroscopy times (218 seconds [IQR: 110,5-446 seconds] vs. 310 seconds [IQR 190-640 seconds]; p = 0.012), which consecutively leads to a reduction of radiation exposure signified by a lower dose area product (155 cGycm² [IQR 74.4-334.5 cGycm²] vs. 368.4 cGycm² [IQR: 126-905.4 cGycm²]; p value 0.009). Acute procedural success rates were comparable in both groups (54 [84.3%] in the single catheter approach group and 58 [90.6%] in the conventional group; p: 0.287). CONCLUSION: A single catheter approach for the treatment of PVC is associated with a reduction of procedure- and fluoroscopy time, as well as a lesser radiation exposure, while maintaining equivalent acute success and complication rates compared with a conventionally used catheter setup.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Humans , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/surgery , Catheter Ablation/adverse effects , Catheters , Fluoroscopy , Propensity Score
6.
Europace ; 26(1)2023 12 28.
Article in English | MEDLINE | ID: mdl-38127308

ABSTRACT

AIMS: Recurrences of ventricular tachycardia (VT) after initial catheter ablation is a significant clinical problem. In this study, we report the efficacy and risks of repeat VT ablation in patients with structural heart disease (SHD) in a tertiary single centre over a 7-year period. METHODS AND RESULTS: Two hundred ten consecutive patients referred for repeat VT ablation after previous ablation in our institution were included in the analysis (53% ischaemic cardiomyopathy, 91% males, median age 65 years, mean left ventricular ejection fraction 35%). After performing repeat ablation, the clinical VTs were acutely eliminated in 82% of the patients, but 46% of the cohort presented with VT recurrence during the 25-month follow-up. Repeat ablation led to a 73% reduction of shock burden in the first year and 61% reduction until the end of follow-up. Similarly, VT burden was reduced 55% in the first year and 36% until the end of the study. Fifty-two patients (25%) reached the combined endpoint of ventricular assist device implantation, heart transplantation, or death. Advanced New York Heart Association functional class, anteroseptal substrate, and periprocedural complication after repeat ablation were associated with worse prognosis independently of the type of cardiomyopathy. CONCLUSION: While complete freedom from VT after repeat ablation in SHD was difficult to achieve, ablation led to a significant reduction in VT and shock burden. Besides advanced heart failure characteristics, anteroseptal substrate and periprocedural complications predicted a worse outcome.


Subject(s)
Cardiomyopathies , Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Male , Humans , Aged , Female , Stroke Volume , Ventricular Function, Left , Heart Diseases/etiology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/etiology , Cardiomyopathies/complications , Cardiomyopathies/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome , Recurrence
7.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37960936

ABSTRACT

AIMS: Low-voltage areas (LVAs) found during left atrial (LA) electroanatomical mapping are increasingly targeted by radiofrequency catheter ablation (RFCA) on top of pulmonary vein isolation to improve arrhythmia-free survival in patients with atrial fibrillation (AF). However, pre-procedural prediction of LVAs remains challenging. The purpose of the present study was to describe the association between parameters of LA function and dimensions, respectively, derived from pre-procedural cardiovascular magnetic resonance (CMR) imaging, and the presence of LVAs on LA voltage mapping. METHODS AND RESULTS: Patients who underwent first-time RFCA for paroxysmal or persistent AF and who were in stable sinus rhythm during pre-procedural CMR imaging were included in this study. Cardiovascular magnetic resonance-derived parameters of LA function and dimensions were calculated. Low-voltage areas were defined as areas with bipolar voltage amplitudes of ≤0.5 mV on electroanatomical mapping. In total, 259 consecutive patients were included in this analysis. Low-voltage areas were found in 25 of 259 patients (9.7%). Compared with those without LVAs, patients with LVAs were significantly older, were more likely to be female, had a higher CHA2DS2-VASc score, had larger LA volumes, and had a lower LA total emptying fraction (TEF). In multivariate analysis, only LA TEF [odds ratio (OR) 0.885, 95% confidence interval (CI) 0.846-0.926, P < 0.001] and the CHA2DS2-VASc score (OR 1.507, 95% CI 1.115-2.038, P = 0.008) remained independently associated with the presence of LVAs. CONCLUSION: Left atrial TEF and the CHA2DS2-VASc score were independently associated with the presence of LVAs found during LA electroanatomical mapping. These findings may help to improve pre-procedural prediction of pro-arrhythmogenic LVAs and to improve peri-procedural patient management.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Female , Male , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Heart Atria/diagnostic imaging , Heart Atria/surgery , Magnetic Resonance Imaging , Atrial Appendage/surgery , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Catheter Ablation/methods
8.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37656979

ABSTRACT

AIMS: Same-day discharge (SDD) following catheter ablation (CA) of atrial fibrillation (AF) was already introduced in selected facilities in Europe, but a widespread implementation has not yet succeeded. Data on patients' perspectives are lacking. Therefore, we conducted a survey to address patients' beliefs towards SDD and identify variables that are associated with their evaluation. METHODS AND RESULTS: As part of the prospective, monocentric FAST AFA trial, patients aged ≥20 years undergoing left atrial CA for AF were asked to participate in the survey consisting of a study-specific questionnaire, the AF knowledge scale, and pre-defined patient-reported outcome measures. The study cohort was stratified based on SDD willingness, and a logistic regression analysis was used to identify predictors for patients' valuation. Between 26 July 2021 and 01 July 2022, 256 of 376 screened patients consented to study participation of whom 248 (mean age 61.8 years, 33.9% female) completed the SDD survey. Of them, 50.0% were willing to have SDD concepts integrated into their clinical course with increased patient comfort (27.5%), shorter waiting times (14.6%), and a cost-efficient treatment (14.0%) being imaginable benefits. In contrast, expressed concerns included uncertainties with occurring complaints (50.6%), the insufficient recognition (47.8%), and treatment (48.9%) of complications. European Heart Rhythm Association class at baseline and inpatient treatments within the preceding year were predictors for SDD willingness whereas comorbidity burden or AF knowledge were not. CONCLUSION: We provide a detailed survey expressing patients' beliefs towards SDD following left atrial CA. Our findings may facilitate adequate patient selection to improve the future implementation of SDD programs in suitable cohorts.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Female , Humans , Male , Middle Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Hospitalization , Patient Discharge , Prospective Studies , Young Adult , Adult
10.
J Clin Med ; 12(11)2023 May 30.
Article in English | MEDLINE | ID: mdl-37297951

ABSTRACT

Myocarditis is an inflammatory disease of the myocardium with a wide range of potential etiological factors, including a variety of infectious agents (mainly viral), systemic diseases, drugs, and toxins.

11.
J Cardiovasc Electrophysiol ; 34(2): 403-411, 2023 02.
Article in English | MEDLINE | ID: mdl-36434796

ABSTRACT

BACKGROUND AND OBJECTIVE: Cardiac tamponade during ablation procedures is a life-threatening complication. While the incidence and management of tamponade in atrial fibrillation ablation have been extensively described, the data on tamponade during ventricular ablations are very limited. The purpose of this study is to shed light on the incidence, typical perforation sites, and optimal management as observed through real-life data in a tertiary referral center for ventricular ablation. METHODS AND RESULTS: Consecutive patients with structural heart disease undergoing ventricular tachycardia ablation from 2008-2020 were analyzed. Of the 1078 patients undergoing 1287 ventricular ablation procedures, 20 procedures (1.5%) were complicated by cardiac tamponade. In all but one patient, the tamponade was treated with emergent pericardial drainage, while nine patients eventually underwent surgical repair. The perforation occurred during transseptal or subxiphoid puncture in six patients, during ventricle mapping in two patients, and during ablation in five patients (predominantly basal left ventricle). Steam pop as definite perforation cause could only be established in two patients. Regardless of the management of the complication, all patients survived to discharge. CONCLUSION: Cardiac tamponade during ventricular ablation occurred in 1.5% of the procedures. In nine patients cardiac repair was necessary. Perforation was mostly associated with subxiphoid puncture or ablation of the basal left ventricle.


Subject(s)
Atrial Fibrillation , Cardiac Tamponade , Catheter Ablation , Humans , Cardiac Tamponade/epidemiology , Cardiac Tamponade/etiology , Cardiac Tamponade/therapy , Incidence , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Heart Ventricles , Punctures/adverse effects , Catheter Ablation/adverse effects , Catheter Ablation/methods , Treatment Outcome
12.
Eur Heart J Acute Cardiovasc Care ; 12(1): 69-73, 2023 Jan 27.
Article in English | MEDLINE | ID: mdl-36574428

ABSTRACT

Electrical storm (ES) is a medical emergency that is defined as ≥ 3 separate ventricular tachycardia (VT) episodes causing ICD therapy within 24 h. Patients with ES have high risk for hospitalization, heart failure (HF) decompensation, in-hospital death. Furthermore, it is associated with significant anxiety and distress for the patients. Frequent triggers of ES are myocardial ischaemia, acute decompensation of HF, metabolic and electrolyte disorders, drug side-effects, increased sympathetic tone. Acute management of ES requires sedation, antiarrhythmic drugs and correction of the precipitating factors; although, in severe refractory cases, intubation, mechanical ventilation, and circulatory support might be necessary. Radiofrequency catheter ablation is superior than antiarrhythmic drugs to suppress the ES and is also frequently required to terminate the ES, as well as to achieve acute and long-term freedom of VT. Optimization of the ICD programming is crucial to reduce the burden of further appropriate and inappropriate shocks. Use of appropriate discrimination criteria and algorithms, ATPs and extending the detection times are important measures to reduce the burden of ES. In patients with end-stage HF, ES can be a sign of failing heart and can be refractory of treatment. In such cases, deactivation of the ICD therapy should be considered and discussed with patients and their care givers.


Subject(s)
Defibrillators, Implantable , Heart Failure , Tachycardia, Ventricular , Humans , Anti-Arrhythmia Agents/therapeutic use , Hospital Mortality , Defibrillators, Implantable/adverse effects , Tachycardia, Ventricular/diagnosis , Arrhythmias, Cardiac/etiology , Heart Failure/drug therapy , Treatment Outcome
13.
J Interv Cardiol ; 2022: 6829725, 2022.
Article in English | MEDLINE | ID: mdl-35935125

ABSTRACT

Background: Catheter ablation of ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) is an effective tool to prevent VT recurrences. Chronic total occlusion (CTO) represents a clinically relevant entity in ICM patients and is an independent predictor of ventricular arrhythmia and mortality. The effects of CTO on the outcome of VT ablation are not well-studied. Objective: This analysis aimed to identify the impact of CTO, revascularized, or not revascularized, on the outcome of VT ablation. Methods and Results: Of 385 consecutive subjects with ICM-VT who underwent catheter VT ablation for monomorphic VT at Heart Center Leipzig between 2008 and 2017, 108 patients without CTO and 191 patients with CTO were included in the analysis. Within a median follow-up time of 557 days (IQR 149, 1095), VT recurred in 77 (40%) patients in the CTO and 40 (37.0%) in the non-CTO cohort (p = 0.62). In a multivariable model, a 10% stepwise change in LVEF as well as ICD on admission was associated with VT recurrence (HRadj 1.82, 95% CI 1.04-3.18 and HRadj 1.35, 95% CI 1.23-1.61, respectively). Of the CTO cohort before ablation, 45% had received revascularization, which was independently associated with a higher risk for VT recurrence (HR 2.12, 95% CI 1.35-3.34) as compared to nonrevascularized CTO. Conclusion: In ICM patients with and without CTO, VT ablation was associated with equal effectiveness with regard to VT recurrence. However, in revascularized CTO patients, the risk of recurrence of VT after ablation was significantly increased.


Subject(s)
Cardiomyopathies , Catheter Ablation , Myocardial Ischemia , Tachycardia, Ventricular , Cardiomyopathies/complications , Cardiomyopathies/surgery , Catheter Ablation/methods , Humans , Myocardial Ischemia/complications , Myocardial Ischemia/surgery , Recurrence , Tachycardia, Ventricular/complications , Tachycardia, Ventricular/surgery , Treatment Outcome
14.
Europace ; 24(11): 1800-1808, 2022 11 22.
Article in English | MEDLINE | ID: mdl-35851396

ABSTRACT

AIM: Cardiac sympathetic denervation (CSD) has been introduced as a bailout therapy in patients with structural heart disease and refractory ventricular arrhythmias (VAs), but available data are scarce. Purpose of this study was to estimate immediate results, complications, and mid-term outcomes of CSD following recurrent VA after catheter ablation. METHODS AND RESULTS: Adult patients who underwent CSD in the Heart Center Leipzig from March 2017 to February 2021 were retrospectively analysed. Follow-up (FU) was executed via implantable cardioverter defibrillator (ICD) interrogation, telephone interviews, and reviewing medical records. Twenty-one patients (age 63.7 ± 14.4 years, all men, 71.4% non-ischaemic cardiomyopathy, left ventricular ejection fraction 31.6 ± 12.6%) received CSD via video-assisted thoracoscopic surgery (90.5% bilateral, 9.5% left-sided only). Indication for CSD was monomorphic ventricular tachycardia in 76.2% and ventricular fibrillation in 23.8 with 71.4% of patients presenting with electrical storm before index hospitalization. Procedure-related major complications occurred in 9.5% of patients. In-hospital adverse events not related to surgery were common (28.6%) and two patients died during the index hospital stay. During FU (mean duration 9.1 ± 6.5 months), five more patients died. Of the remaining patients, 38.5 and 76.9% were free from any VA or ICD shocks, respectively. CONCLUSIONS: The CSD showed additional moderate efficacy to suppress VAs, when performed as a bailout therapy after previously unsuccessful catheter ablation. At 9 months, it was associated with freedom of ICD shocks in two-thirds of patients. In a population with many comorbidities, the rate of CSD-related complications was acceptable, although there was an overall high risk of procedure unrelated adverse events and death.


Subject(s)
Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Adult , Male , Humans , Middle Aged , Aged , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Sympathectomy/adverse effects , Sympathectomy/methods , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/surgery
15.
Front Cardiovasc Med ; 9: 869730, 2022.
Article in English | MEDLINE | ID: mdl-35463751

ABSTRACT

Background: Consumer smartwatches have gained attention as mobile health (mHealth) tools able to detect atrial fibrillation (AF) using photoplethysmography (PPG) or a short strip of electrocardiogram (ECG). PPG has limited accuracy due to the movement artifacts, whereas ECG cannot be used continuously, is usually displayed as a single-lead signal and is limited in asymptomatic cases. Objective: DoubleCheck-AF is a validation study of a wrist-worn device dedicated to providing both continuous PPG-based rhythm monitoring and instant 6-lead ECG with no wires. We evaluated its ability to differentiate between AF and sinus rhythm (SR) with particular emphasis on the challenge of frequent premature beats. Methods and Results: We performed a prospective, non-randomized study of 344 participants including 121 patients in AF. To challenge the specificity of the device two control groups were selected: 95 patients in stable SR and 128 patients in SR with frequent premature ventricular or atrial contractions (PVCs/PACs). All ECG tracings were labeled by two independent diagnosis-blinded cardiologists as "AF," "SR" or "Cannot be concluded." In case of disagreement, a third cardiologist was consulted. A simultaneously recorded ECG of Holter monitor served as a reference. It revealed a high burden of ectopy in the corresponding control group: 6.2 PVCs/PACs per minute, bigeminy/trigeminy episodes in 24.2% (31/128) and runs of ≥3 beats in 9.4% (12/128) of patients. AF detection with PPG-based algorithm, ECG of the wearable and combination of both yielded sensitivity and specificity of 94.2 and 96.9%; 99.2 and 99.1%; 94.2 and 99.6%, respectively. All seven false-positive PPG-based cases were from the frequent PVCs/PACs group compared to none from the stable SR group (P < 0.001). In the majority of these cases (6/7) cardiologists were able to correct the diagnosis to SR with the help of the ECG of the device (P = 0.012). Conclusions: This is the first wearable combining PPG-based AF detection algorithm for screening of AF together with an instant 6-lead ECG with no wires for manual rhythm confirmation. The system maintained high specificity despite a remarkable amount of frequent single or multiple premature contractions.

16.
Herzschrittmacherther Elektrophysiol ; 33(2): 217-223, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35277790

ABSTRACT

OBJECTIVES: This study analyzes the incidence, characteristics, and ECG morphology of ventricular tachycardia (VT) in post-infarction patients undergoing epicardial VT ablation. BACKGROUND: Ablation of recurrent VTs in patients with ischemic cardiomyopathy is typically performed endocardially. In rare cases, epicardial access is required to achieve non-inducibility. METHODS AND RESULTS: The study evaluated the baseline characteristics, procedural data, and ECG morphology of clinical VT in patients undergoing epicardial VT ablation. From the initial 491 patients with coronary heart disease (CHD) and recurrent VTs undergoing ablation at the Heart Center of Leipzig, Germany, between 2012 and 2020, only 39 patients required an additional epicardial access. In 17 patients, the VTs were associated with infarction scar, while the remaining patients had concomitant CHD without infarction-associated scar and were excluded from the analysis. A propensity match study was performed at a 1:2 ratio for these 17 patients, with 34 patients of the initial cohort as a control group to evaluate the differences in baseline characteristics, procedural data, and ECG morphology of the VTs. The specific VT morphology of negative concordance and superior axis in patients with inferior scar as well as the history of VT ablation were independent predictors of the need for epicardial access. CONCLUSIONS: In addition to previous endocardial ablation, VT ECG morphology with negative concordance and superior axis in post-infarction patients with inferior scar predicted the need for epicardial VT ablation.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Catheter Ablation/methods , Cicatrix/complications , Cicatrix/diagnosis , Cicatrix/surgery , Electrocardiography/methods , Humans , Infarction/complications , Infarction/surgery , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Treatment Outcome
17.
JACC Case Rep ; 3(16): 1756-1759, 2021 Nov 17.
Article in English | MEDLINE | ID: mdl-34825204

ABSTRACT

A 25-year-old male patient with highly symptomatic, monomorphic, premature ventricular contractions presented for repeat ablation after failed endocardial ablation. Three weeks after excessive endocardial and epicardial ablation on the left ventricular summit, the patient was admitted again with tamponade following a pseudoaneurysm on the ablation site. (Level of Difficulty: Advanced.).

18.
Europace ; 23(12): 1980-1988, 2021 12 07.
Article in English | MEDLINE | ID: mdl-34405874

ABSTRACT

AIMS: Epicardial ablation has risen to an essential part of the treatment of ventricular tachycardias (VTs). In this study, we report the efficacy, risks, and current trends of epicardial ablation in structural heart disease as reported in a tertiary single centre over a 12-year period. METHODS AND RESULTS: Two hundred and thirty-six patients referred for VT ablation underwent a successful epicardial access and were included in the analysis (89% non-ischaemic cardiomyopathy, 90% males, mean age 60 years, mean left ventricular ejection fraction 38.4%). After performing epicardial ablation the clinical VTs were eliminated in 87% of the patients and 71% of the cohort achieved freedom from VT during 22-month follow-up. Twelve patients (5%) suffered major procedure-related complications. Until the end of follow-up 47 (20%) patients died, 9 (4%) underwent a left ventricular assist device implantation and 10 (4%) patients received a heart transplantation. Antiarrhythmic drugs at baseline and during follow-up were independent predictors of VT recurrence. Atrial fibrillation, renal dysfunction, worse New York Heart Association class, and antiarrhythmic drugs at follow-up were associated with worse survival in our cohort. CONCLUSION: In this large tertiary single-centre experience, percutaneous epicardial access was feasible in the large majority of the cohort with acceptably low complications rates. A combined endo-/epicardial approach resulted in 87% acute and 71% long-term success. Further studies are needed to clarify the role of routine combined endo-/epicardial ablation in these complex cardiomyopathies.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Heart Diseases/complications , Humans , Male , Middle Aged , Recurrence , Stroke Volume , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Treatment Outcome , Ventricular Function, Left
19.
J Cardiovasc Electrophysiol ; 32(10): 2675-2683, 2021 10.
Article in English | MEDLINE | ID: mdl-34411387

ABSTRACT

INTRODUCTION: This study sought to examine gender differences in patients with structural heart disease (SHD) referred for ablation of ventricular tachycardia (VT). BACKGROUND: Female patients are often underrepresented in large studies. Significant differences in the clinical presentation, treatment, and prognosis of female patients have been described in previous studies. METHODS AND RESULTS: We investigated 88 female patients with SHD undergoing VT ablation (mean age 59 years, 56% nonischemic cardiomyopathy, mean left ventricular ejection fraction 35%, 82% in electrical storm). A case-control study with 88 male patients was performed and the results regarding clinical and procedural characteristics, acute and long-term results of the two groups were compared. The female patients had more arrhythmogenic substrate, as they more commonly presented with electrical storm (p = .016) and had a higher number of inducible VT morphologies during the procedure (p = .018). Moreover, the female patients were less likely to have an optimized heart failure medical treatment at baseline (p = .030) and required more time from the first manifestation of the VT to ablation referral (p = .034). Although fewer epicardial ablations were performed in female patients (p = .019), the two groups showed similar results regarding VT noninducibility as ablation endpoint (p = .844), major procedure-related complications (p = .719) and freedom from VT during follow-up (p = .268). Moreover, the overall mortality in the two groups was similar (p = .176). Advanced NYHA class was associated with worse transplant and assist-device-free survival in the female group. CONCLUSION: Female patients presenting for VT ablation had more arrhythmogenic substrate and were less likely to have an optimized heart failure medical treatment. Nevertheless, the procedural acute and long-term outcomes between the two genders were similar.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Case-Control Studies , Catheter Ablation/adverse effects , Female , Humans , Male , Middle Aged , Recurrence , Sex Factors , Stroke Volume , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome , Ventricular Function, Left
20.
Herzschrittmacherther Elektrophysiol ; 32(3): 353-358, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34269843

ABSTRACT

INTRODUCTION: Ablation of ventricular tachycardias (VTs) in patients with structural heart disease (SHD) has been associated with advanced heart failure and poor survival. METHODS AND RESULTS: This matched case-control study sought to assess the difference in survival after left ventricular assist device (LVAD) implantation and/or heart transplantation (HTX) in SHD patients undergoing VT ablation. From the initial cohort of 309 SHD patients undergoing VT ablation (187 ischemic cardiomyopathy, mean age 64 ± 12 years, ejection fraction of 34 ± 13%), 15 patients received an LVAD and nine patients HTX after VT ablation during a follow-up period of 44 ± 33 months. Long-term survival after LVAD did not differ from the matched control group (p = 0.761), although the cause of lethal events was different. All post-HTX patients survived during follow-up. CONCLUSION: In this matched case-control study on patients with SHD undergoing VT ablation, patients that received LVAD implantation had similar survival compared to the control group after 4­year follow-up, while the patients with HTX had a significantly better outcome.


Subject(s)
Catheter Ablation , Heart Diseases , Heart Transplantation , Tachycardia, Ventricular , Aged , Case-Control Studies , Humans , Middle Aged , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...