Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
J Interv Card Electrophysiol ; 11(3): 205-9, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15548887

ABSTRACT

Brugada syndrome is a well-known form of idiopathic ventricular fibrillation (VF). Few data suggest that this arrhythmia may be triggered by ventricular premature beats (VPBs), and an association with other arrhythmia such as monomorphic ventricular tachycardia (VT) or supraventricular tachycardia (SVT) has been reported. In a highly symptomatic 18-year-old-male patient with this syndrome, frequent episodes of VF, fast polymorphic VT, and fast monomorphic sustained regular tachycardia were observed. The tachycardia episodes were classified as VT or VF and as a consequence received appropriate therapies with the implanted cardioverter defibrillator (ICD). Precipitating VPBs that were stored in the ICD memory and on the electrocardiogram (ECG) exhibited the same morphology as frequent isolated VPBs. During the electrophysiological study, right and left atrial tachycardia (AT) with one-to-one atrioventricular conduction were also induced and successfully ablated. VF was ablated using the same noncontact mapping (NCM) system triggering VPBs from right ventricular outflow tract (RVOT).


Subject(s)
Catheter Ablation , Tachycardia, Supraventricular/surgery , Tachycardia, Ventricular/surgery , Ventricular Fibrillation/surgery , Adolescent , Electric Countershock , Electrocardiography , Humans , Male , Syndrome , Tachycardia, Supraventricular/physiopathology , Tachycardia, Ventricular/physiopathology , Ventricular Fibrillation/physiopathology
3.
Pacing Clin Electrophysiol ; 26(1P2): 233-8, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12687819

ABSTRACT

The aim of this prospective multicenter study was to assess the clinical benefits of the Selection (Vitatron) pacemaker diagnostic functions (AF 1.0) in the management of AF. Forty patients (71 +/- 9 years of age), with documented AF and conventional pacing indications, received a Selection. The AF 1.0 function of the pacemaker was programmed to document the AF burden, onset, daily distribution, duration, premature atrial beats before onset, and mode of onset of the last 12 episodes for AF episodes exceeding 180 beats/min. By comparing patients' symptoms records, patient conventional assessment at follow-up and AF 1.0 data, the investigators evaluated the usefulness of AF 1.0 in AF management at 3- and 6-month follow-ups. Usefulness was defined as a change in arrhythmia management prompted by the disclosure of AF 1.0 data. AF recurrences were recorded in 71% of the follow-ups with symptoms reported by patients in only 16%. Thirty-nine percent of therapeutic changes based on conventional assessment were confirmed by AF 1.0 data, and in 61% of instances, the initial changes were modified by AF 1.0 data. Changes included pacing parameters in 56% of cases, AF prevention with pacing algorithms in 37%, and medical treatment in 7%. All investigators indicated that AF 1.0 was useful in all patients. The AF 1.0 diagnostic functions offered a unique documentation of AF in asymptomatic patients, and allowed therapeutic adjustments impossible otherwise.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Pacemaker, Artificial , Aged , Atrial Fibrillation/complications , Cardiac Pacing, Artificial/methods , Female , Humans , Male , Prospective Studies , Sick Sinus Syndrome/complications
SELECTION OF CITATIONS
SEARCH DETAIL
...