Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Electrophysiol ; 28(9): 1037-1047, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28639728

ABSTRACT

AIMS: Late recovery of ablated tissue leading to reconnection of pulmonary veins remains common following radiofrequency catheter ablation for AF. Ablation Index (AI), a novel ablation quality marker, incorporates contact force (CF), time, and power in a weighted formula. We hypothesized that prospective use of our previously published derived AI targets would result in better outcomes when compared to CF-guided ablation. METHODS: Eighty-nine consecutive drug-refractory AF patients (49% paroxysmal) underwent AI-guided ablation (AI-group). AI targets were 550 for anterior/roof and 400 for posterior/inferior left atrial segments. Procedural and clinical outcomes of these patients were compared to 89 propensity-matched controls who underwent CF-guided ablation (CF-group). All 178 procedures were otherwise similar, and both groups were followed-up for 12 months. The last 25 patients from each group underwent analysis of all VisiTags™ for ablation duration, CF, Force-Time Integral, and impedance drop. RESULTS: First-pass pulmonary vein isolation (PVI) was more frequent in AI-group than in CF-group (173 [97%] vs. 149 [84%] circles, P < 0.001), and acute PV reconnection was lower (11 [6%] vs. 24 [13%] circles, P = 0.02). Mean PVI ablation time was similar (AI-group: 42 ± 9 vs. CF-group: 45 ± 14 minutes, P = 0.14). Median impedance drop for AI-group was significantly higher than in CF-group (13.7 [9-19] Ω vs. 8.8 [5.2-13] Ω, P < 0.001). Two major complications occurred in CF-group and none in AI-group. Atrial tachyarrhythmia recurrence was significantly lower in AI-group (15 of 89 [17%]) than in CF-group (33 of 89 [37%], P = 0.002). CONCLUSION: AI-guided ablation is associated with significant improvements in the incidence of acute PV reconnection and atrial tachyarrhythmia recurrence rate compared to CF-guided ablation, potentially due to creation of better quality lesions as suggested by greater impedance drop.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria/physiopathology , Heart Conduction System/surgery , Pulmonary Veins/surgery , Atrial Fibrillation/physiopathology , Female , Follow-Up Studies , Heart Conduction System/physiopathology , Humans , Male , Middle Aged , Postoperative Period , Prospective Studies , ROC Curve , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...