1.
Polymers (Basel) ; 12(7)2020 Jul 03.
Article in English | MEDLINE | ID: mdl-32635323

ABSTRACT

Lithium phenyl (2,4,6-trimethylbenzoyl) phosphinate (LAP) is a free radical photo-initiator used to initiate free radical chain polymerization upon light exposure, and is combined with gelatin methacryloyl (GelMA) to produce a photopolymer used in bioprinting. The free radicals produced under bioprinting conditions are potentially cytotoxic and mutagenic. Since these photo-generated free radicals are highly-reactive but short-lived, toxicity assessments should be conducted with light exposure. In this study, photorheology determined that 10 min exposure to 9.6 mW/cm2 405 nm light from an LED light source fully crosslinked 10 wt % GelMA with >3.4 mmol/L LAP, conditions that were used for subsequent cytotoxicity and mutagenicity assessments. These conditions were cytotoxic to M-1 mouse kidney collecting duct cells, a cell type susceptible to lithium toxicity. Exposure to ≤17 mmol/L (0.5 wt %) LAP without light was not cytotoxic; however, concurrent exposure to ≥3.4 mmol/L LAP and light was cytotoxic. No condition of LAP and/or light exposure evaluated was mutagenic in bacterial reverse mutation assays using S. typhimurium strains TA98, TA100 and E. coli WP2 uvrA. These data indicate that the combination of LAP and free radicals generated from photo-excited LAP is cytotoxic, but mutagenicity was not observed in bacteria under typical bioprinting conditions.

2.
Int Urogynecol J ; 31(7): 1435-1441, 2020 07.
Article in English | MEDLINE | ID: mdl-31243497

ABSTRACT

INTRODUCTION AND HYPOTHESIS: Surgical repair of pelvic organ prolapse often includes native tissue repair during which the patient's own vaginal connective tissue is used to achieve pelvic support. This method, based on plication and suspension often yields suboptimal anatomical outcomes, possibly due to inadequate healing of the vaginal connective tissue. We hypothesized that age might have a negative effect on the time course and tissue biomechanics of vaginal wound healing in a rat model. METHODS: Fifty young (12 weeks) and old (12 months) female 344BN Fischer rats were subjected to a posterior midline vaginal incision. The time course of repair was determined by measuring the size of the wound on days 1, 3, 7, and 14 post-injury. These findings correlated with the immune response to injury using a marker of impaired wound healing, the inflammatory cytokine macrophage migration inhibitory factor in the vaginal muscularis. Biomechanical properties of the healed vaginal tissue were tested 30 days post-injury. RESULTS: Wound healing was assessed on days 1, 3, 7, and 14 post-injury. On day 3 post-injury, the wounds in the young animals had all closed whereas the wounds in the old animals remained open. Furthermore, on day 7, the wound gap was still filled with granulation tissue in the old rats, whereas for the young rats, the wound area was almost indistinguishable from the non-injured area. Macrophage migration inhibitory factor was highly expressed in the vaginal epithelium and in the vaginal muscularis after injury. When compared with young animals, macrophage migration inhibitory factor levels of old rats began to rise more than 2 days later and the increased tissue expression persisted for 7 days longer. The breakpoint force of the healed vagina of old rats was almost 4-fold weaker than in young rats. At 30 days post-injury, the healed vagina in old rats regained less of the original (healthy) force at breakpoint than the young rats. CONCLUSIONS: In this rat model, age impaired vaginal wound healing, which was reflected in the altered inflammatory response to injury and reduced tissue strength.


Subject(s)
Pelvic Organ Prolapse , Wound Healing , Animals , Female , Granulation Tissue , Immunity , Rats , Vagina
3.
J Test Eval ; 48(1)2019 Mar 07.
Article in English | MEDLINE | ID: mdl-36147246

ABSTRACT

Personal protective equipment (PPE), such as gowns used in the latest Ebola outbreak in Western Africa, are critical in preventing the spread of deadly diseases. Appropriate test systems and test soils are needed to adequately evaluate PPE. ASTM F903, Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Liquid, has been used for decades to test fabrics' resistance to liquid penetration. However, this test apparatus requires at least 60 mL of test solutions, is labor intensive, and has problems with leakage around the gaskets. We compared the F903 test apparatus to a modified dot-blot apparatus to evaluate the visual penetration of a blood test soil. A series of commercially available gowns and drapes were tested in each apparatus. Using blood test soil at 2 psi, there was no statistically significant difference between the two methods except for in one gown. By comparing this gown in the ASTM test apparatus with and without a screen, the particular screen selected did not account for the difference between the dot-blot and F903 apparatuses; however, it is conceivable that a particular screen/fabric combination could account for this difference. The modified dot-blot apparatus was evaluated using three different test solutions: blood, vomit, and a labeled protein (goat anti-rabbit immunoglobulin G-horseradish peroxidase [GaR IgG-HRP]) in a blood test soil solution. This testing revealed significant difference in penetration for some of the PPE garments. The modified dot-blot had several large advantages over the ASTM apparatus-over six times less specimen volume and no edge or gasket leakage. In addition, nitrocellulose can be easily incorporated into the modified dot-blot apparatus, enabling the trapping of viruses and proteins that penetrate PPE-thus permitting the use of antibodies to quickly and sensitively detect penetration.

4.
Pharm Dev Technol ; 22(1): 35-44, 2017 Feb.
Article in English | MEDLINE | ID: mdl-26895348

ABSTRACT

Potential connections between release profiles and solvent evaporation rates alongside polymer chemistry were elucidated for the release of tetracycline hydrochloride from two different poly (d, l-lactide-co-glycolide) (PLGA) film matrices containing high drug fractions (50%, 30%, and 15%), and prepared at two distinct solvent evaporation rates. At highest tetracycline concentrations (50%), (i) the early release rates were ≤0.5 µg/min in all cases; (ii) release was linear from systems fabricated with lower lactic content and slower solvent evaporation rate and bimodal from systems fabricated with higher lactic content and faster evaporation rate; (iii) surface fractions covered by the drug were similar at both evaporation rates for 85:15 PLGA but very different for 50:50 PLGA, leading to unexpectedly reduced early release from 50:50 PLGA than from 85:15 PLGA when both the matrices were fabricated using a slower evaporation rate. These features remained unaffected in case of low drug concentration. Results suggested that during the formation of the drug-polymer microstructure, the combined effect of polymer chemistry and solvent evaporation rate sets apart the surface characteristics and the initial release profiles of systems containing high drug fraction, and an appropriate combination of these parameters may be utilized to control the early stage of drug release.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Delayed-Action Preparations/chemistry , Drug Liberation , Lactic Acid/chemistry , Polyglycolic Acid/chemistry , Tetracycline/administration & dosage , Anti-Bacterial Agents/chemistry , Polylactic Acid-Polyglycolic Acid Copolymer , Solubility , Solvents/chemistry , Tetracycline/chemistry , Volatilization
5.
J Biomed Mater Res B Appl Biomater ; 105(5): 1210-1215, 2017 07.
Article in English | MEDLINE | ID: mdl-27061945

ABSTRACT

A simple and rapid method has been developed for testing bacterial endotoxin in hyaluronic acid (HA)-based medical devices. High-molecular-weight HA (HMW HA) in solution or HA-based medical devices was digested by the enzyme hyaluronidase to reduce solution viscosity by truncating the long chains of HA and to test for bacterial endotoxin. The bacterial endotoxin level was detected and measured by kinetic chromogenic Limulus Amebocyte Lysate (LAL) assay. The method was applied to two different ophthalmic viscosurgical devices (OVDs) and one dermal filler, and may easily be adapted to use with up to 3% HA solutions and other HA-based medical devices. Published 2016. This article is a U.S. Government work and is in the public domain in the USA. J Biomed Mater Res Part B: Appl Biomater, 2016. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1210-1215, 2017.


Subject(s)
Equipment Contamination , Equipment and Supplies , Hyaluronic Acid/chemistry , Lipopolysaccharides/analysis , Ophthalmologic Surgical Procedures/instrumentation , Animals , Cattle , Humans
6.
Biomaterials ; 95: 74-85, 2016 07.
Article in English | MEDLINE | ID: mdl-27131630

ABSTRACT

Ultrasoft biomaterials-polymers, gels, and human soft tissues with an elastic modulus less than ∼100 kPa-are increasingly used in medical devices. While bacterial interactions (adhesion and biofilm formation) have been extensively studied on stiffer materials, little is known about how bacteria colonize ultrasoft materials as a nidus for infection. The goal of this work was to determine how material properties of ultrasoft hydrogels used for dermal fillers might affect pathogenesis of associated infections. We first synthesized a range of polyacrylamide hydrogels (PAAm) with moduli similar to clinically used dermal fillers and characterized the rheological, morphological and porous properties. We then developed a novel microfabricated insert to contain the PAAm in a flow system for quantification of bacterial adhesion and biofilm formation. The rate of adhesion and numbers of adherent Staphylococcus aureus on the surface of PAAm both decreased as the modulus increased. Adhesion was reduced by 3 logs (from 93 × 10(4)/cm(2) to 0.083 × 10(4)/cm(2)) with increasing modulus (from 17 Pa to 654 Pa). However, the number of bacteria in the bulk was the highest within the stiffest gels. This trend was further amplified in subsequent biofilm studies, where interfacial coverage of biofilm decreased as the modulus increased, while the fraction of biofilm in the bulk was the highest within the stiffest gel. The results show significant differences in bacterial colonization of PAAm based on material properties, and reveal how the injection process may unexpectedly create discontinuities that provide a microenvironmental niche for bacterial colonization.


Subject(s)
Acrylic Resins/pharmacology , Staphylococcus aureus/drug effects , Acrylic Resins/chemistry , Bacterial Adhesion/drug effects , Biofilms/drug effects , Elastic Modulus , Green Fluorescent Proteins/genetics , Humans , Hydrogels , Porosity , Regeneration , Rheology , Staphylococcus aureus/genetics , Surface Properties
7.
Contraception ; 90(1): 86-93, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24680185

ABSTRACT

BACKGROUND: Male condoms act as mechanical barriers to prevent passage of body fluids. For effective use of condoms the mechanical seal is also expected to remain intact under reasonable use conditions, including with personal lubricants. Absorption of low molecular weight lubricant components into the material of male condoms may initiate material changes leading to swelling and stress relaxation of the polymer network chains that could affect performance of the sealing function of the device. Swelling indicates both a rubber-solvent interaction and stress relaxation, the latter of which may indicate and/or result in a reduced seal pressure in the current context. METHODS: Swelling and stress relaxation of natural rubber latex condoms were assessed in a laboratory model in the presence of silicone-, glycol-, and water-based lubricants. RESULTS: Within 15 minutes, significant swelling (≥6 %) and stress reduction (≥12 %) of condoms were observed with 2 out of 4 silicone-based lubricants tested, but neither was observed with glycol- or water-based lubricants tested. Under a given strain, reduction in stress was prominent during the swelling processes, but not after the process was complete. CONCLUSIONS: Lubricant induced swelling and stress relaxation may loosen the circumferential stress responsible for the mechanical seal. Swelling and stress relaxation behavior of latex condoms in the presence of personal lubricants may be useful tests to identify lubricant-rooted changes in condom-materials. IMPLICATION: For non-lubricated latex condoms, material characteristics--which are relevant to failure--may change in the presence of a few silicone-based personal lubricants. These changes may in turn induce a loss of condom seal during use, specifically at low strain conditions.


Subject(s)
Condoms , Lubricants/chemistry , Rubber/chemistry , Elastic Modulus , Glycols/chemistry , Humans , Male , Silicones/chemistry , Water/chemistry
8.
Med Devices (Auckl) ; 6: 49-57, 2013.
Article in English | MEDLINE | ID: mdl-23690701

ABSTRACT

The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body.

9.
J Biomed Mater Res B Appl Biomater ; 95(1): 9-18, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20665680

ABSTRACT

Iron-crosslinked hyaluronic acid hydrogel (FeHA) has been used to reduce postsurgical adhesions in patients undergoing open, gynecological surgery. The performance of FeHA gel as an adhesion barrier device is influenced by many factors, including the physicochemical gel properties, which, in turn, depend on the chemistry and conditions of the device manufacturing. In this work, we demonstrate the effect of reaction pH on rheology and homogeneity of FeHA gels formulated in house and also compare the viscoelastic properties of FeHA gels with that of uncrosslinked HA solution of similar HA concentration and ionic strength. Dynamic mechanical analyses provide evidence that the reaction of HA with Fe(III) ions leads to the formation of "weak" gels. The viscoelastic properties and homogeneity of FeHA gels vary depending on the pH at which crosslinking was initiated. When solution pH, at the start of crosslinking, varied between 1.5 and 3, the low-shear rate viscosity of FeHA varied between 10,000 and 40,000 cPoise (10-40 Pa s). The highest steady-state shear viscosity and viscoelasticity were measured when pH was around 2.6, which is similar to the pH-dependent viscoelasticity of pure HA solution. Initiating HA crosslinking at pH ≤ 3 led to relatively homogenous solutions, while crosslinking higher pH > 3 caused instantaneous gel precipitation and inhomogeneities. Sensitivity of FeHA gel properties to small variations in reaction pH clearly supports the need for a tight manufacturing control during medical device fabrication.


Subject(s)
Gels/chemistry , Hyaluronic Acid/therapeutic use , Materials Testing/methods , Tissue Adhesions/prevention & control , Cross-Linking Reagents , Elasticity , Gels/therapeutic use , Hyaluronic Acid/chemistry , Hydrogen-Ion Concentration , Iron/chemistry , Postoperative Care/methods , Viscosity
10.
J Biomed Mater Res B Appl Biomater ; 85(2): 398-408, 2008 May.
Article in English | MEDLINE | ID: mdl-17969017

ABSTRACT

Samples of full-length glove-fingers cut from chlorinated and nonchlorinated latex medical examination gloves were aged for various times at several fixed temperatures and 25% relative humidity. Creep testing was performed using an applied stress of 50 kPa on rectangular specimens (10 mm x 8 mm) of aged and unaged glove fingers as an assessment of glove loosening during usage. Variations in creep curves obtained were compared to determine the threshold aging time when the amount of creep became larger than the initial value. These times were then used in various models to estimate shelf lives at lower temperatures. Several different methods of extrapolation were used for shelf-life estimation and comparison. Neither Q-factor nor Arrhenius activation energies, as calculated from 10 degrees C interval shift factors, were constant over the temperature range; in fact, both decreased at lower temperatures. Values of Q-factor and activation energies predicted up to 5 years of shelf life. Predictions are more sensitive to values of activation energy as the storage temperature departs from the experimental aging data. Averaging techniques for prediction of average activation energy predicted the longest shelf life as the curvature is reduced.


Subject(s)
Gloves, Protective , Latex , Stress, Mechanical , Time Factors