Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
Phys Med ; 46: 45-51, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29519408

ABSTRACT

PURPOSE: Early assessment of tumour response to treatment with repeated FDG-PET-CT imaging has potential for treatment adaptation but it is unclear what the optimal time window for this evaluation is. Previous studies indicate that changes in SUVmean and the effective radiosensitivity (αeff, accounting for uptake variations and accumulated dose until the second FDG-PET-CT scan) are predictive of 2-year overall survival (OS) when imaging is performed before radiotherapy and during the second week. This study aims to investigate if multiple FDG-PET-derived quantities determined during the third treatment week have stronger predictive power. METHODS: Twenty-eight lung cancer patients were imaged with FDG-PET-CT before radiotherapy (PET1) and during the third week (PET2). SUVmean, SUVmax, SUVpeak, MTV41%-50% (Metabolic Tumour Volume), TLG41%-50% (Total Lesion Glycolysis) in PET1 and PET2 and their change (), as well as average αeff (α¯eff) and the negative fraction of αeff values [Formula: see text] ) were determined. Correlations were sought between FDG-PET-derived quantities and OS with ROC analysis. RESULTS: Neither SUVmean, SUVmax, SUVpeak in PET1 and PET2 (AUC = 0.5-0.6), nor their changes (AUC = 0.5-0.6) were significant for outcome prediction purposes. Lack of correlation with OS was also found for α¯eff (AUC = 0.5) and [Formula: see text] (AUC = 0.5). Threshold-based quantities (MTV41%-50%, TLG41%-50%) and their changes had AUC = 0.5-0.7. P-values were in all cases ≫0.05. CONCLUSIONS: The poor OS predictive power of the quantities determined from repeated FDG-PET-CT images indicates that the third week of treatment might not be suitable for treatment response assessment. Comparatively, the second week during the treatment appears to be a better time window.


Subject(s)
Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/therapy , Fluorodeoxyglucose F18 , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/therapy , Positron Emission Tomography Computed Tomography , Aged , Aged, 80 and over , Chemoradiotherapy , Female , Humans , Male , Middle Aged , Time Factors , Treatment Outcome
2.
Radiat Prot Dosimetry ; 180(1-4): 338-341, 2018 Aug 01.
Article in English | MEDLINE | ID: mdl-29036696

ABSTRACT

The microdosimetric variance-covariance method was used to study the stray radiation fields from the photon therapy facility at the Technical University of Denmark and the scanned proton therapy beam at the Skandion Clinic in Uppsala, Sweden. Two TEPCs were used to determine the absorbed dose, the dose-average lineal energy, the dose-average quality factor and the dose equivalent. The neutron component measured by the detectors at the proton beam was studied through Monte Carlo simulations using the code MCNP6. In the photon beam the stray absorbed dose ranged between 0.3 and 2.4 µGy per monitor unit, and the dose equivalent between 0.4 and 9 µSv per monitor unit, depending on beam energy and measurement position. In the proton beam the stray absorbed dose ranged between 3 and 135 µGy per prescribed Gy, depending on detector position and primary proton energy.


Subject(s)
Photons/adverse effects , Protons/adverse effects , Radiation Protection/methods , Radiometry/methods , Radiotherapy/adverse effects , Radiotherapy/instrumentation , Computer Simulation , Humans , Monte Carlo Method
3.
Cell Biochem Biophys ; 75(3-4): 299-309, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28756482

ABSTRACT

Head and neck squamous cell carcinoma (HNSCC) tumours are associated with high mortality despite advances in therapy. The monoclonal antibody cetuximab (Erbitux®) has been approved for the treatment of advanced HNSCC. However, only a subset of HNSC patients receiving cetuximab actually responds to treatment, underlining the need for a means to tailor treatments of individual patients. The aim of the present study was to investigate the effect of cetuximab treatment on tumour growth, on tumour partial oxygen pressure as measured by LiPc electron paramagnetic resonance oximetry and on the expression of proteins involved in tumour growth, metabolism and hypoxia. Two HNSCC cell lines, UT-SCC-2 and UT-SCC-14, were used to generate xenografts on female BALB/c (nu/nu) nude mice. Mice with xenografts were given three injections of intraperitoneal cetuximab or phosphate-buffered saline, and the tumour volume was recorded continuously. After treatment the tumour partial oxygen pressure was measured by LiPc electron paramagnetic resonance oximetry and the expression of epidermal growth factor receptor (EGFR), phosphorylated EGFR, Ki-67, MCT1, MCT4, GLUT1, CAIX and HIF-1α were investigated by immunohistochemistry. In xenografts from both cell lines (UT-SCC-2 and UT-SCC-14) cetuximab had effect on the tumour volume but the effect was more pronounced on UT-SCC-14 xenografts. A higher tumour oxygenation was measured in cetuximab-treated tumours from both cell lines compared to untreated controls. Immunocytochemical staining after cetuximab treatment shows a significantly decreased expression of EGFR, pEGFR, Ki67, CAIX and nuclear HIF-1α in UT-SCC-14 tumours compared to untreated controls. MCT1 and GLUT1 were significantly decreased in tumours from both cell lines but more pronounced in UT-SCC-14 tumours. Taken together, our results show that cetuximab treatment decreases the tumour growth and increases the tumour partial oxygen pressure of HNSCC xenografts. Furthermore we found a potential connection between the partial oxygen pressure of the tumours and the expression of proteins involved in tumour growth, metabolism and hypoxia.


Subject(s)
Antineoplastic Agents, Immunological/therapeutic use , Carcinoma, Squamous Cell/drug therapy , Cetuximab/therapeutic use , Electron Spin Resonance Spectroscopy , Head and Neck Neoplasms/drug therapy , Oximetry , Animals , Carcinoma, Squamous Cell/metabolism , Carcinoma, Squamous Cell/pathology , Cell Line, Tumor , Disease Models, Animal , ErbB Receptors/metabolism , Female , Glucose Transporter Type 1/metabolism , Head and Neck Neoplasms/metabolism , Head and Neck Neoplasms/pathology , Humans , Hypoxia , Hypoxia-Inducible Factor 1, alpha Subunit/metabolism , Immunohistochemistry , Ki-67 Antigen/metabolism , Mice , Mice, Inbred BALB C , Mice, Nude , Oxygen/analysis , Transplantation, Heterologous
4.
Radiat Prot Dosimetry ; 161(1-4): 357-62, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24353029

ABSTRACT

Ionising radiation is increasingly used for the treatment of cancer, being the source of a considerable fraction of the medical irradiation to patients. With the increasing success rate of cancer treatments and longer life expectancy of the treated patients, the issue of secondary cancer incidence is of growing concern, especially for paediatric patients who may live long after the treatment and be more susceptible to carcinogenesis. Also, additional imaging procedures like computed tomography, kilovoltage and megavoltage imaging and positron emission tomography, alone or in conjunction with radiation therapy, may add to the radiation burden associated with the risk of occurrence of secondary cancers. This work has been based on literature studies and is focussed on the assessment of secondary doses to healthy tissues that are delivered by the use of modern radiation therapy and diagnostic imaging modalities in the clinical environment.


Subject(s)
Neoplasms, Radiation-Induced/etiology , Neoplasms, Radiation-Induced/prevention & control , Radiation Dosage , Radiation Protection/instrumentation , Radiation Protection/methods , Radiotherapy, Intensity-Modulated/instrumentation , Radiotherapy, Intensity-Modulated/methods , Anthropometry , Heavy Ions/adverse effects , Humans , Phantoms, Imaging , Photons , Positron-Emission Tomography/adverse effects , Protons/adverse effects , Radiation, Ionizing , Radiotherapy, Intensity-Modulated/adverse effects , Tomography, X-Ray Computed/adverse effects
5.
Clin Oncol (R Coll Radiol) ; 19(5): 289-301, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17517328

ABSTRACT

There has been an intense debate over the past several years on the relevant alpha/beta value that could be used to describe the fractionation response of prostate tumours. Previously it has been assumed that prostate tumours have high alpha/beta values, similar to most other tumours and the early reacting normal tissues. However, the proliferation behaviour of the prostate tumours is more like that of the late reacting tissues, with slow doubling times and low alpha/beta values. The analyses of clinical results carried out in the past few years have indeed suggested that the alpha/beta value that characterises the fractionation response of the prostate is low, possibly even below the 3 Gy commonly assumed for most late complications, and hence that hypofractionation of the radiation treatment might improve the therapeutic ratio (better control at the same or lower complication rate). However, hypofractionation might also increase the complication rates in the surrounding late responding tissues and if their alpha/beta value is not larger that of prostate tumours it could even lead to a decrease in the therapeutic ratio. Therefore, the important question is whether the alpha/beta value for the prostate is lower than the alpha/beta values of the surrounding late responding tissues at risk. This paper reviews the clinical and experimental data regarding the radiobiological differential that might exist between prostate tumours and the late normal tissues around them. Several prospective hypofractionated trials that have been initiated recently in order to determine the alpha/beta value or the range of values that describe the fractionation response of prostate tumours are also reviewed. In spite of several confounding factors that interfere with the derivation of a precise value, it seems that most data support a trend towards lower alpha/beta values for prostate tumours than for rectum or bladder.


Subject(s)
Dose Fractionation, Radiation , Prostatic Neoplasms/radiotherapy , Brachytherapy , Clinical Trials as Topic , Dose-Response Relationship, Radiation , Humans , Male , Radiation Injuries , Rectum/radiation effects , Treatment Outcome
6.
Physiol Meas ; 22(4): 713-25, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11761078

ABSTRACT

The aim of this article is to determine the correlation between the actual oxygen distribution in tissues and the distribution of oxygen measured by microelectrodes. This correlation is determined by the response function of the electrode, which depends on the oxygen consumed by the electrode. In tissue it is necessary to consider the gradients resulting from cellular respiration. A computer program has been used to simulate the vascular structure of various tissues and also the measurements of oxygen tension using a polarographic electrode. The electrode absorption process is described using a theoretical model. The gradient of oxygen in tissue is described by a mathematical model that takes into consideration both diffusion and cellular consumption of oxygen. We have compared the results obtained using the response function of the electrode and some simplifications of it. The results of these comparisons show that there are some differences in the 'observed' distributions of the oxygen tension in tissues predicted using different formulae for the electrode response function. Also, there are considerable differences between the input oxygen distribution and the measured values in all cases. All the results of the simulations of the oxygen tension 'observed' by a 12 microm polarographic electrode, using different response functions of the electrode, show that the electrode averages the values from many cells. Care should be taken in using a simplification for the response function of the electrode, especially if the results are going to be used as input values in modelling the tumour response to new treatments and/or as a basis of selecting patients for treatments. A computer simulation of measurement of oxygen tensions in regions of steep pO2 gradients shows that extremely high and extremely low pO2 values will not be detected.


Subject(s)
Microelectrodes , Oximetry/instrumentation , Oxygen/blood , Algorithms , Computer Simulation , Humans , Models, Biological
8.
Radiat Res ; 153(3): 279-88, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10669549

ABSTRACT

Two groups have proposed a simple linear relationship between inducible radioresistance in a variety of mammalian cells and their intrinsic radiosensitivity at 2 Gy (Lambin et al., Int.J. Radiat. Biol. 69, 279-290, 1996; Alsbeih and Raaphorst, unpublished results, 1997). The inducible repair response (IRR) is quantified as a ratio, alpha(S)/alpha(R), i.e. the slope in the hypersensitive low-dose region, alpha(S), relative to the alpha(R) term of the classical linear-quadratic formula. These proposals imply that the intrinsic radiosensitivity at clinically relevant doses is directly linked to the cell's ability to mount an adaptive response as a result of exposure to very low doses of radiation. We have re-examined this correlation and found that the more extensive data set now available in the literature does not support the contention of a simple linear relationship. The two parameters are correlated, but by a much more complex relationship. A more logical fit is obtained with a log-linear equation. A series of log-linear curves are needed to describe the correlation between IRR and SF2, because of the spectrum of alpha/beta ratios among the cell lines and hence the confounding effect of the beta term at a dose of 2 Gy. The degree of repair competence before irradiation starts could also be a major factor in the apparent magnitude of the amount of repair induced. There appears to be a systematic difference in the data sets from different series of cell lines that have been obtained using flow cytometry techniques in the laboratory in Vancouver and using dynamic microscope imaging at the Gray Laboratory. We suggest that the use of a brief exposure to a laser beam in flow cytometry before the cells are irradiated might itself partially induce a stress response and change the DNA repair capacity of the cells. The clinical consequences of the relationship for predicting the benefits of altered fractionation schedules are discussed. [ru5]


Subject(s)
DNA Repair , Radiation Tolerance , Animals , Cell Line , Cell Survival/radiation effects , Dose-Response Relationship, Radiation , Mammals
9.
Acta Oncol ; 38(7): 903-18, 1999.
Article in English | MEDLINE | ID: mdl-10606420

ABSTRACT

Clinical experience shows that there is a therapeutic window between 60 and 70 Gy where many tumours are eradicated, but the function of the adjacent normal tissues is preserved. This implies much more cell kill in the tumour than is acceptable in the normal tissue. An SF2 of 0.5 or lower is needed to account for the eradication of all tumour cells, while an SF2 of 0.8 or higher is needed to explain why these doses are tolerated by normal tissues. No such systematic difference is known between the intrinsic sensitivity of well-oxygenated normal and tumour cells. The presence of radioresistant hypoxic cells in tumours makes it even more difficult to understand the clinical success. However, there is experimental evidence that starved cells lose their repair competence as a result of the depletion of cellular energy charge. MRS studies have shown that low ATP levels are a characteristic feature of solid tumours in rodents and man. In this paper we incorporate the concept of repair incompetence in starving, chronically hypoxic cells. The increased sensitivity of such cells has been derived from an analysis of mammalian cell lines showing inducible repair. It is proportional to the SF2 and highest in resistant cells. The distinction between acutely hypoxic radioresistant cells and chronically hypoxic radiosensitive cells provides the key to the realistic modelling of successful radiotherapy. It also opens new conceptual approaches to radiotherapy. We conclude that it is essential to distinguish between these two kinds of hypoxic cells in predictive assays and models.


Subject(s)
Cell Hypoxia , DNA Repair , Neoplasms/radiotherapy , Cell Survival/radiation effects , Dose-Response Relationship, Radiation , Humans , Models, Biological , Neoplasms/metabolism , Radiation Tolerance
10.
Int J Radiat Oncol Biol Phys ; 43(5): 1083-94, 1999 Mar 15.
Article in English | MEDLINE | ID: mdl-10192360

ABSTRACT

PURPOSE: A dose "window of opportunity" has been identified in an earlier modeling study (1) if the inducible repair variant of the LQ model is adopted instead of the pure LQ model, and if all survival curve parameters are equally modified by the presence or absence of oxygen. In this paper we have extended the calculations to consider survival curve parameters from 15 sets of data obtained for cells tested at low doses using clonogenic assays. METHODS AND MATERIALS: A simple computer model has been used to simulate the response of each cell line to various doses per fraction in multifraction schedules, with oxic and hypoxic cells receiving the same fractional dose. We have then used pairs of simulated survival curves to estimate the effective hypoxic protection (OER') as a function of the dose per fraction. RESULTS: The resistance of hypoxic cells is reduced by using smaller doses per fraction than 2 Gy in all these fractionated clinical simulations, whether using a simple LQ model, or the more complex LQ/IR model. If there is no inducible repair, the optimum dose is infinitely low. If there is inducible repair, there is an optimum dose per fraction at which hypoxic protection is minimized. This is usually around 0.5 Gy. It depends on the dose needed to induce repair being higher in hypoxia than in oxygen. The OER' may even go below unity, i.e. hypoxic cells may be more sensitive than oxic cells. CONCLUSIONS: If oxic and hypoxic cells are repeatedly exposed to doses of the same magnitude, as occurs in clinical radiotherapy, the observed hypoxic protection varies with the fractional dose. The OER' is predicted to diminish at lower doses in all cell lines. The loss of hypoxic resistance with superfractionation is predicted to be proportional to the capacity of the cells to induce repair, i.e. their intrinsic radioresistance at a dose of 2 Gy.


Subject(s)
Cell Hypoxia/radiation effects , Cell Survival/radiation effects , Computer Simulation , Dose Fractionation, Radiation , Cell Hypoxia/physiology , Cell Line/radiation effects , Cell Survival/physiology , Linear Models , Models, Biological , Radiation Tolerance , Radiobiology
11.
Int J Radiat Oncol Biol Phys ; 42(4): 705-9, 1998 Nov 01.
Article in English | MEDLINE | ID: mdl-9845081

ABSTRACT

PURPOSE: To model the influence of hypoxic radioprotection in fractionated treatments over a range of fraction sizes. To determine whether there is a "therapeutic window" of dose per fraction where hypoxic radioresistance could be reduced, and if so, where it occurs in different cell lines. MATERIALS AND METHODS: A mathematical model has been used to simulate the response of cells to low doses of radiation, in the region of clinical interest. We have used the inducible repair variant of the linear quadratic (LQ) equation, with a hypersensitive region (alphaS) at low doses that gradually transforms to the accepted "resistance" in the shoulder region (alphaR). It contains two new parameters, the ratio alphaS/alphaR, and D(C). We have accepted that the "induction dose" D(C) is modified by anoxia to the same extent as the other parameters. We have initially modeled using theoretical parameters and then checked the conclusions with 14 sets of published experimental data for cell lines investigated for inducible repair. RESULTS: We have computed the clinical hypoxic protection (OER') as a function of dose per fraction in simulations of clinical fractionated schedules. We have identified a therapeutic window in terms of dose per fraction at about 0.5 Gy, where the OER' is minimized, regardless of the precise cell survival curve parameters. The minimum OER' varies from one cell line to another, falling to about 1.0 if alphaS/alphaR = 6-10 and even far below 1.0 if alphaS/alphaR > or = 20. DISCUSSION: Hyperfractionation using 0.5 Gy fractions may therefore be more effective than oxygen mimetic chemical sensitizers, since it could even make some tumor cells more sensitive than oxic normal tissues. The tumor lines that benefit most from this type of sensitization are those with the highest intrinsic oxic radioresistance, i.e. those with high SF2 values.


Subject(s)
Cell Hypoxia/physiology , Dose Fractionation, Radiation , Models, Biological , Radiation Tolerance , Cell Hypoxia/radiation effects , Cell Survival , Linear Models
12.
Adv Enzyme Regul ; 38: 281-99, 1998.
Article in English | MEDLINE | ID: mdl-9762359

ABSTRACT

This paper illustrates how the concept of the malignant cell per se as the prime and only target in cancer therapy may be erroneous. The micro-vasculature evoked to satisfy nutritional requirements of solid tumors, and the inadequacy of this nutrition for all tumor cells, provide novel targeting concepts. The vascular architecture and the microenvironmental gradients (VAMP) will differ from one tumor to another and may determine whether current therapies succeed or fail. Many agents have a different toxicity or mode of action at the pathophysiological oxygen tensions that prevail in solid tumors. This warrants more attention. The hypoxic cell or the immature proliferating endothelial cell may provide tumor specificity that is more general than, and greater than, that conferred by the process of malignant transformation. The poor vasculature of solid tumors is often regarded as a problem by the oncologist. It limits the access of cytotoxic drugs, monoclonal antibodies, cytokines, etc. It also leads to hypoxic radioresistance because of diffusion limited chronic hypoxia and perfusion limited intermittent hypoxia, resulting from transient vessel closure. However, it can also be seen as a potential target, since prolonged vessel occlusion can lead to an avalanche of cell death. Strategies to prevent further expansion of the vascular network (anti-angiogenesis) should stabilize tumors and prevent further growth. Vascular targeting, aiming to damage the microvascular function and cause occlusion, can lead to extensive cell death. The target may relate to the excessive proliferation of endothelial cells in tumors or to abnormal functional aspects, such as altered cell shape (influencing permeability) adhesiveness to leukocytes or steps in the coagulation cascade. These microvascular features and microenvironmental gradients, and the phenotypic consequences of them, have been relatively neglected. The altered milieu and inadequate neovasculature is a common feature of all types of solid tumor, whereas the genetic changes that can give rise to a malignancy are very variable, from tumor site to site and even within a site from individual to individual. It seems, therefore, that therapies that could be of widespread general applicability might more easily be found from the micro-environmental or anti-vascular approaches than from gene therapy targeted at specific oncogenes. This approach will require cross fertilisation between scientists from quite disparate backgrounds, whose paths seldom cross, and who may not read, or even scan, each other's literature. If the endothelium or the low oxygen tension in subsets of tumor cells are the key to successful cancer treatment in mice, there are considerable implications for screening methods in vitro and for predictive and prognostic tests made on homogenized tumor samples.


Subject(s)
Microcirculation/physiology , Neoplasms/therapy , Cell Hypoxia/drug effects , Cell Survival/radiation effects , Neoplasms, Experimental/pathology , Neovascularization, Pathologic/pathology
13.
Radiother Oncol ; 46(3): 269-77, 1998 Mar.
Article in English | MEDLINE | ID: mdl-9572620

ABSTRACT

BACKGROUND AND PURPOSE: This paper deals with the variations in the oxygen enhancement ratios that could be observed (OER') when comparing oxic and hypoxic cells in different types of fractionated experiments as a consequence of the non-linearity of the underlying cell survival curves. Calculations have been made of the OER' that would be obtained for fractionated irradiations with a series of small doses to allow the comparison of isoeffective doses in oxic and hypoxic conditions. Two styles of fractionated experiment were modelled. In one, the dose per fraction was kept constant in the oxic and hypoxic arms of the experiment, necessitating more fractions in hypoxia to achieve the same level of cell kill. In the other the number of fractions was kept constant and the fraction size was varied to obtain equal levels of damage. The first is the relevant design for the clinic, whereas the second is the design most commonly used in animal studies. MATERIALS AND METHODS: Three models of the survival curve were used to simulate the response of cells to radiation injury, all based on the linear quadratic model, but with various added assumptions. A simple classical LQ model is compared with two models in which the concept of inducible repair is added. In one of these the induction dose for 'switching on' the more resistant response is assumed to be increased in hypoxia and in the other it is assumed to be independent of the oxygen tension. RESULTS: These calculations show a clear and previously unsuspected dependence of the measured OER' on the design of the fractionated experiment. The values obtained in the clinical and animal types of study differ considerably with all three models. The direction and magnitude of that difference depends critically on the assumptions about the fine structure of the survival curve shape. The authors suggest that the inducible repair version with an oxygen-dependent induction dose is probably the most relevant model. Using this, the measured OER' is reduced at doses around 2 Gy for the clinically relevant design of constant sized fractions to the oxic and hypoxic cells. It may even, in certain model assumptions, fall below unity resulting in an increased sensitivity, not resistance, from the hypoxia. CONCLUSIONS: These calculations indicate the urgent need for more knowledge about the fine structure of the low dose region of the survival curves for human tumour cells and especially for comparisons in the presence and absence of oxygen. The extent of the hypersensitivity at very low doses, the trigger dose needed to induce the repair and its oxygen modification may be dominant factors in determining the response of tumour cells to clinically relevant fractionation schedules.


Subject(s)
Cell Survival/radiation effects , Hypoxia/physiopathology , Oxygen Consumption , Radiation Injuries, Experimental/etiology , Tumor Cells, Cultured/radiation effects , Animals , Dose-Response Relationship, Radiation , Humans , Linear Models , Models, Biological , Radiation Dosage , Radiation Injuries, Experimental/metabolism , Radiation Tolerance
14.
Phys Med Biol ; 43(1): 21-36, 1998 Jan.
Article in English | MEDLINE | ID: mdl-9483621

ABSTRACT

A new liquid ionization chamber (LIC) design optimized for high spatial resolution was used for measurements of dose distributions in radiation fields intended for stereotactic radiosurgery (SRS). This work was mainly focused on the properties of this detector in radiation fields from linear accelerators for clinical radiotherapy (pulsed radiation with dose rates from approximately 0.5 to 5 Gy min-1 and beam diameters down to 8 mm). The narrow beams used in stereotactic radiosurgery require detectors with small sizes in order to provide a good spatial resolution. The LIC is investigated to see whether it can be used as a detector for dose measurements in beams currently used for stereotactic radiosurgery. Its properties are compared with those of silicon diodes. The comparisons include output factor (OF), depth dose and profile measurements in 6 MV photon fields of different sizes. For OF measurements, an NACP air ionization chamber was also used in the comparison. The dependence of the response on the detector orientation in the photon beam is also investigated for the diodes and the LIC. The results suggest that LICs can provide better properties than diodes for measuring dose distributions in narrow photon beams.


Subject(s)
Radiometry/instrumentation , Radiosurgery , Biophysical Phenomena , Biophysics , Humans , Particle Accelerators , Photons , Radiotherapy Dosage , Radiotherapy, High-Energy
SELECTION OF CITATIONS
SEARCH DETAIL
...