Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 23(2)2023 Jan 16.
Article in English | MEDLINE | ID: mdl-36679828

ABSTRACT

Standing up from a seated position is a prerequisite for any kind of physical mobility but many older persons have problems with the sit-to-stand (STS) transfer. There are several exosuits available for industrial work, which might be adapted to the needs of older persons to support STS transfers. However, objective measures to quantify and evaluate such systems are needed. The aim of this study was to quantify the possible support of an exosuit during the STS transfer of geriatric patients. Twenty-one geriatric patients with a median age of 82 years (1.-3.Q. 79-84 years) stood up at a normal pace (1) from a chair without using armrests, (2) with using armrests and (3) from a bed with pushing off, each condition with and without wearing an exosuit. Peak angular velocity of the thighs was measured by body-worn sensors. It was higher when standing up with exosuit support from a bed (92.6 (1.-3.Q. 84.3-116.2)°/s versus 79.7 (1.-3.Q. 74.6-98.2)°/s; p = 0.014) and from a chair with armrests (92.9 (1.-3.Q. 78.3-113.0)°/s versus 77.8 (1.-3.Q. 59.3-100.7)°/s; p = 0.089) compared to no support. There was no effect of the exosuit when standing up from a chair without using armrests. In general, it was possible to quantify the support of the exosuit using sensor-measured peak angular velocity. These results suggest that depending on the STS condition, an exosuit can support older persons during the STS transfer.


Subject(s)
Movement , Wearable Electronic Devices , Humans , Aged , Aged, 80 and over , Pilot Projects , Thigh
2.
Sensors (Basel) ; 22(4)2022 Feb 11.
Article in English | MEDLINE | ID: mdl-35214307

ABSTRACT

The assessment of sit-to-stand (STS) performance is highly relevant, especially in older persons, but testing STS performance in the laboratory does not necessarily reflect STS performance in daily life. Therefore, the aim was to validate a wearable sensor-based measure to be used under unsupervised daily life conditions. Since thigh orientation from horizontal to vertical is characteristic for STS movement, peak angular velocity (PAV) of the thigh was chosen as the outcome variable. A total of 20 younger and older healthy persons and geriatric patients (mean age: 55.5 ± 20.8 years; 55% women) with a wide range of STS performance were instructed to stand up from a chair at their usual pace. STS performance was measured by an activity monitor, force plates, and an opto-electronic system. The association between PAV measured by the thigh-worn activity monitor and PAV measured by the opto-electronic system (gold standard) was r = 0.74. The association between PAV measured by the thigh-worn activity monitor and peak power measured by force plate and opto-electronic system was r = 0.76. The Intra-Class Coefficient (ICC) of agreement between the 2 trials was ICC(A,1) = 0.76. In this sample of persons with a wide range of physical performance, PAV as measured by a thigh-worn acceleration sensor was a valid and reliable measure of STS performance.


Subject(s)
Movement , Thigh , Adult , Aged , Aged, 80 and over , Female , Fitness Trackers , Humans , Male , Middle Aged , Monitoring, Physiologic , Physical Functional Performance
3.
Wearable Technol ; 3: e22, 2022.
Article in English | MEDLINE | ID: mdl-38486909

ABSTRACT

Industrial exoskeletons have recently gained importance as ergonomic interventions for physically demanding work activities. The growing demand for exoskeletons is leading to a need for new knowledge on the effectiveness of these systems. The Exoworkathlon, as a prospective study approach, aims to assess exoskeletons in realistic use cases and to evaluate them neutrally in their entirety. For this purpose, a first set of four realistic Parcours was developed with experts from relevant industries, the German Social Accident Insurance, and the Federal Institute for Occupational Safety and Health. In addition, a set of ratings was defined to assess subjective user feedback, work quality, and objective physiological parameters. Exoworkathlon aims to bring together developers, researchers, and end-users, strengthen collaborative exchanges, and promote a platform for the prospective holistic data collection for exoskeleton evaluation. In this article, the focus is on the background and methodology of Exoworkathlon.

SELECTION OF CITATIONS
SEARCH DETAIL
...