Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Int Ophthalmol ; 42(9): 2855-2869, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35672599

ABSTRACT

PURPOSE: Impaired digital reactive hyperaemia and flicker-stimulated retinal vascular response are commonly reported risk markers of cardiovascular disease. This is the first study to determine the correlation of these risk markers with diabetes mellitus by comparing our novel flicker-modulated ECG-gated fundoscope with the EndoPAT2000 system. METHODS: In total, 119 controls and 120 participants with diabetes mellitus partook in this cross-sectional study. The EndoPAT2000 system assessed digital reactive hyperaemia under fasting conditions. A mydriatic ECG-gated fundoscope with a novel flicker module acquired digital retinal images of the left eye before, during and after flicker stimulation. An inhouse semi-automated software measured retinal vessel diameters using a validated protocol with two observers repeating measurements in a subset of 10 controls and 10 participants with diabetes mellitus. Intra- and inter-observer reliability analyses occurred by the interclass correlation coefficient. A receiver operating characteristic curve established associations of variables with diabetes mellitus. RESULTS: Diabetes mellitus was more strongly associated with flicker-stimulated retinal arteriolar calibre change from baseline (AUC 0.81, 95% CI 0.75-0.87, p < 0.0001) than reactive hyperaemia index. Median flicker-stimulated arteriolar calibre change from baseline (controls: 2.74%, IQR 1.07 vs diabetes mellitus: 1.64%, IQR 1.25, p < 0.0001) and reactive hyperaemia index (controls: 1.87, IQR 0.81 vs diabetes mellitus: 1.60, IQR 0.81, p = 0.003) were lower in diabetes mellitus than controls. Intra- and inter-observer reliability coefficients were high from 0.87 to 0.93. CONCLUSIONS: Impaired flicker-stimulated retinal arteriolar calibre change from baseline is more highly correlated with diabetes mellitus in this study than a reduced reactive hyperaemia index.


Subject(s)
Diabetes Mellitus , Hyperemia , Cross-Sectional Studies , Electrocardiography , Humans , Manometry , Reproducibility of Results , Retinal Vessels , Vasodilation
2.
J Diabetes Metab Disord ; 21(1): 463-474, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35673505

ABSTRACT

Aims: Endothelial dysfunction is an early risk marker of cardiovascular disease in diabetes mellitus. Timely screening is important in reducing cardiovascular disease-associated morbidity and mortality. This cross-sectional study investigates the acceptability and preferability of non-invasive cardiovascular risk procedures (EndoPAT2000 system and the ECG-gated fundoscope) in participants with diabetes mellitus compared to controls. Methods: A self-administered Likert scale-based questionnaire was completed by 106 controls and 117 participants with diabetes mellitus, identified through stratified random sampling, upon conclusion of an Australian Heart Eye sub-study conducted at Westmead Hospital, NSW, Australia from 2012 to 2014. Pearson's χ 2 test, independent-samples t-test and regression analysis were performed. Results: Study participants who responded to the questionnaire had no preference for procedures (controls: 2.4 ± 1.1 vs diabetes mellitus: 2.5 ± 0.9, p = 0.38) but had an overall more negative experience with most aspects of the ECG-gated fundoscope than the EndoPAT2000 system. Of those with diabetes mellitus, participants who provided poorer self-rated health expressed discomfort with the mydriatic drops (ß 0.27, 95%CI 0.001 - 0.54, p = 0.049) and the fundoscope's green light filter (ß 0.27, 95%CI 0.07 - 0.47, p = 0.009), as well as maintaining still (ß 0.40, 95%CI 0.08 - 0.72, p = 0.02) and not blinking (ß 0.38, 95%CI 0.07 - 0.70, p = 0.02) during photo acquisition. These participants were also less willing to repeat the ECG-gated fundoscope procedure (ß 0.29, 95%CI 0.07 - 0.52, p = 0.01). Conclusions: Participants with diabetes mellitus, especially with poorer self-rated health, had a more negative experience with the ECG-gated fundoscope than the EndoPAT2000 system. Difficulties experienced under examination by the ECG-gated fundoscope appear related to the procedural design, which requires amendments improving patient comfort and compliance.

3.
BMJ Qual Saf ; 31(4): 297-307, 2022 04.
Article in English | MEDLINE | ID: mdl-34408064

ABSTRACT

BACKGROUND: Incorrect, delayed and missed diagnoses can contribute to significant adverse health outcomes. Intervention options have proliferated in recent years necessitating an update to McDonald et al's 2013 systematic review of interventions to reduce diagnostic error. OBJECTIVES: (1) To describe the types of published interventions for reducing diagnostic error that have been evaluated in terms of an objective patient outcome; (2) to assess the risk of bias in the included interventions and perform a sensitivity analysis of the findings; and (3) to determine the effectiveness of included interventions with respect to their intervention type. METHODS: MEDLINE, CINAHL and the Cochrane Database of Systematic Reviews were searched from 1 January 2012 to 31 December 2019. Publications were included if they delivered patient-related outcomes relating to diagnostic accuracy, management outcomes and/or morbidity and mortality. The interventions in each included study were categorised and analysed using the six intervention types described by McDonald et al (technique, technology-based system interventions, educational interventions, personnel changes, structured process changes and additional review methods). RESULTS: Twenty studies met the inclusion criteria. Eighteen of the 20 included studies (including three randomised controlled trials (RCTs)) demonstrated improvements in objective patient outcomes following the intervention. These three RCTs individually evaluated a technique-based intervention, a technology-based system intervention and a structured process change. The inclusion or exclusion of two higher risk of bias studies did not affect the results. CONCLUSION: Technique-based interventions, technology-based system interventions and structured process changes have been the most studied interventions over the time period of this review and hence are seen to be effective in reducing diagnostic error. However, more high-quality RCTs are required, particularly evaluating educational interventions and personnel changes, to demonstrate the value of these interventions in diverse settings.


Subject(s)
Diagnostic Errors , Humans , Diagnostic Errors/prevention & control
4.
Curr Eye Res ; 46(11): 1742-1750, 2021 11.
Article in English | MEDLINE | ID: mdl-33960254

ABSTRACT

Purpose/Aim of this study: Retinal vessel caliber is an independent risk marker of cardiovascular disease risk. However, variable mechanical delays in capturing retinal photographs and cardiac cycle-induced retinal vascular changes have been shown to reduce the accuracy of retinal vessel caliber measurements, but this has only ever been investigated in healthy subjects. This cross-sectional study is the first study to investigate this issue in type 2 diabetes. The aim of this study was to determine whether ECG-gating retinal photographs reduce the variability in retinal arteriolar and venular caliber measurements in controls and type 2 diabetes.Materials and Methods: Fifteen controls and 15 patients with type 2 diabetes were arbitrarily recruited from Westmead Hospital, Sydney, Australia. A mydriatic fundoscope connected to our novel ECG synchronization unit captured 10 ECG-gated (at the QRS) and 10 ungated digital retinal photographs of the left eye in a randomized fashion, blinded to study participants. Two independent reviewers used an in-house semi-automated software to grade single cross-sectional vessel diameters across photographs, between 900 and 1800 microns from the optic disc edge. The coefficient of variation compared caliber variability between retinal arterioles and venules.Results: Our ECG synchronization unit reported the smallest time delay (33.1 ± 48.4 ms) in image capture known in the literature. All 30 participants demonstrated a higher reduction in retinal arteriolar (ungated: 1.02, 95%CI 0.88-1.17% vs ECG-gated: 0.39, 95%CI 0.29-0.49%, p < .0001) than venular (ungated 0.62, 95%CI 0.53-0.73% vs ECG-gated: 0.26, 95%CI 0.19-0.35%, p < .0001) coefficient of variation by ECG-gating photographs. Intra-observer repeatability and inter-observer reproducibility analysis reported high interclass correlation coefficients ranging from 0.80 to 0.86 and 0.80 to 0.93 respectively.Conclusion: ECG-gating photographs at the QRS are recommended for retinal vessel caliber analysis in controls and patients with type 2 diabetes as they refine measurements.


Subject(s)
Cardiovascular Diseases/physiopathology , Diabetes Mellitus, Type 2/physiopathology , Diabetic Retinopathy/physiopathology , Electrocardiography/methods , Photography/methods , Retinal Artery/pathology , Retinal Vein/pathology , Adult , Cardiovascular Diseases/diagnostic imaging , Cross-Sectional Studies , Diabetes Mellitus, Type 2/diagnostic imaging , Diabetic Retinopathy/diagnostic imaging , Female , Humans , Male , Middle Aged , Observer Variation , Ophthalmoscopes , Reproducibility of Results , Retinal Artery/diagnostic imaging , Retinal Vein/diagnostic imaging , Surveys and Questionnaires
5.
NPJ Sci Learn ; 4: 16, 2019.
Article in English | MEDLINE | ID: mdl-31583118

ABSTRACT

Although numerous survey studies have reported connections between sleep and cognitive function, there remains a lack of quantitative data using objective measures to directly assess the association between sleep and academic performance. In this study, wearable activity trackers were distributed to 100 students in an introductory college chemistry class (88 of whom completed the study), allowing for multiple sleep measures to be correlated with in-class performance on quizzes and midterm examinations. Overall, better quality, longer duration, and greater consistency of sleep correlated with better grades. However, there was no relation between sleep measures on the single night before a test and test performance; instead, sleep duration and quality for the month and the week before a test correlated with better grades. Sleep measures accounted for nearly 25% of the variance in academic performance. These findings provide quantitative, objective evidence that better quality, longer duration, and greater consistency of sleep are strongly associated with better academic performance in college. Gender differences are discussed.

SELECTION OF CITATIONS