Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
2.
Circ Cardiovasc Interv ; 16(12): e013199, 2023 12.
Article in English | MEDLINE | ID: mdl-37955163

ABSTRACT

BACKGROUND: Radiation shielding is mandatory during cardiac catheterization, but there is a need to improve efficacy and ease of use. METHODS: The aim of the study was to assess the shielding effect and user feedback for a novel flexible multiconfiguration x-ray shield (FMX). The 0.5-mm Pb equivalent FMX can be selectively configured to accommodate for variations in patient morphology, access site, and type of procedure with maintained visualization, vascular access, and shielding. To evaluate efficacy, relative operator dose (operator dose indexed for given dose) was measured during 103 consecutive procedures randomized in a 1:1 proportion to the current routine setup or FMX+routine. User feedback was collected on function, relevance, and likelihood of adoption into clinical practice. RESULTS: Median relative operator dose was 3.63 µSv/µGy·m2×10-3 (IQR, 2.62-6.37) with routine setup and 0.57 µSv/µGy·m2×10-3 (IQR, 0.27-1.06) with FMX+routine, which amounts to an 84.4% reduction (P<0.001). For 500 procedures/year, this corresponds to an estimated yearly dose reduction from 3.6 to 0.7 mSv. User feedback regarding size, functionality, ease of use, likely to use, critical issues, shielding, draping, procedure time, vascular access, patient discomfort, and risk was 99% positive. No critical issues were identified. There was no significant difference in patient radiation exposure. CONCLUSIONS: The FMX reduces radiation exposure considerably. The FMX represents an effective and attractive solution for radiation protection that can easily be implemented in existing workflow. FMX has potential for general use with maintained visualization, vascular access, and shielding in routine cardiac catheterization.


Subject(s)
Occupational Exposure , Radiation Exposure , Radiation Protection , Humans , X-Rays , Radiation Dosage , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control , Treatment Outcome , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Radiography, Interventional/adverse effects , Radiography, Interventional/methods , Fluoroscopy/adverse effects
3.
Rev Med Liege ; 78(2): 99-106, 2023 Feb.
Article in French | MEDLINE | ID: mdl-36799327

ABSTRACT

Pulmonary hypertension (PH) is a common clinical condition linked to chronic cardiopulmonary illnesses. It must be distinguished from pulmonary arterial hypertension (PAH), a rare disease characterized by a specific involvement of the pulmonary arterial bed. An early diagnosis and accurate classification by a multidisciplinary team are necessary for a multimodal and individualized therapy approach. This article aims to provide a summary of the most recent ESC/ERS recommendations published in 2022.


L'hypertension pulmonaire (HTP) est une entité clinique fréquemment retrouvée chez les patients atteints d'affections cardio-pulmonaires chroniques. Elle est à différentier de l'hypertension artérielle pulmonaire (HTAP) qui est, quant à elle, une maladie rare caractérisée par une atteinte spécifique du lit artériel pulmonaire. Une identification précoce et une classification correcte, en équipe pluridisciplinaire, sont primordiales pour une prise en charge thérapeutique multimodale et personnalisée. Cet article a pour but de résumer, de façon pratique, les dernières recommandations des sociétés européennes de cardiologie (ESC) et de pneumologie (ERS) publiées en 2022.


Subject(s)
Hypertension, Pulmonary , Pulmonary Arterial Hypertension , Humans , Hypertension, Pulmonary/diagnosis , Hypertension, Pulmonary/therapy , Early Diagnosis , Risk Assessment
4.
PLoS One ; 17(11): e0277436, 2022.
Article in English | MEDLINE | ID: mdl-36356038

ABSTRACT

BACKGROUND: There is increasing concern and focus in the interventional cardiology community on potential long term health issues related to radiation exposure and heavy wearable protection. Optimized shielding measures may reduce operator dose to levels where lighter radioprotective garments can safely be used, or even omitted. X-ray blankets (XRB) are commercially available but suffer from small size and lack of stability. A larger XRB may reduce operator dose but could hamper vascular access and visualization. The aim of this study is to assess shielding effect of an optimized XRB during cardiac catheterization and estimate the potential reduction in annual operator dose based on DICOM Radiation Dose Structured Report (RDSR) data reflecting everyday clinical practice. METHODS: Data accumulated from 7681 procedures over three years in our RDSR repository was used to identify projection angles and radiation doses during cardiac catheterization. Using an anthropomorphic phantom and a scatter radiation detector, radiation dose to the operator (mSv) and patient (dose area product-DAP) was measured for each angiographic projection for three different shielding setups. Relative operator dose (mSv/DAP) was calculated and multiplied by DAP per projection to estimate effect on operator dose. RESULTS: Adding an optimized XRB to a standard shielding setup comprising a table- and ceiling-mounted shield resulted in a 94.9% reduction in estimated operator dose. The largest shielding effect was observed in left and cranial projections where the ceiling-mounted shield offered less protection. CONCLUSIONS: An optimized XRB is a simple shielding measure that has the potential to reduce operator dose.


Subject(s)
Occupational Exposure , Radiation Exposure , Humans , X-Rays , Occupational Exposure/prevention & control , Radiation Exposure/prevention & control , Cardiac Catheterization/methods , Radiography, Interventional/adverse effects , Radiography, Interventional/methods , Coronary Angiography/methods , Radiation Dosage
5.
J Interv Cardiol ; 2020: 9602942, 2020.
Article in English | MEDLINE | ID: mdl-32934609

ABSTRACT

BACKGROUND: Percutaneous coronary intervention exposes patient and staff to ionizing radiation. Although staff only receive a small fraction of patient dose through scatter radiation, there are concerns about the potential health effects of repeated exposure. Minimizing both patient and occupational exposure is needed. OBJECTIVE: This article investigates patient and operator X-ray exposure over time in coronary intervention in relation to upgraded X-ray equipment, improved shielding, and enhanced operator awareness. MATERIALS AND METHODS: Data regarding irradiation time, patient dose, and patient characteristics were extracted from the Norwegian Registry for Invasive Cardiology (NORIC) for procedures performed from 2013 to mid-2019. Personal operator dosimetry records were provided by the Norwegian Radiation and Nuclear Safety Authority. Improved operator shielding and awareness measures were introduced in 2018. RESULTS: In the period 2013 through June 2019, 21499 procedures were recorded in our institution. Mean dose area product (DAP) for coronary angiography decreased 37% from 2981 µGy·m2 in 2013 to 1891 µGy·m2 in 2019 (p < 0.001). For coronary intervention, DAP decreased 39% from 8358 µGy·m2 to 5055 µGy·m2. Personal dosimetry data indicate a 70% reduction in operator dose per procedure in 2019 compared to 2013. The most pronounced reduction occurred after improved radiation protection measures were implemented in 2018 (-48%). CONCLUSIONS: This study shows a temporal trend towards considerable reduction in X-ray doses received by the patient and operator during cardiac catheterization. Upgraded X-ray equipment, improved shielding, and enhanced operator awareness are likely contributors to this development.


Subject(s)
Coronary Angiography , Percutaneous Coronary Intervention , Radiation Exposure/prevention & control , Radiologic Health/trends , Coronary Angiography/instrumentation , Coronary Angiography/methods , Coronary Angiography/standards , Humans , Occupational Exposure/prevention & control , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/standards
7.
Resuscitation ; 140: 178-184, 2019 07.
Article in English | MEDLINE | ID: mdl-31009694

ABSTRACT

AIMS: To assess characteristics and outcome of patients treated with Impella for acute myocardial infarction (AMI) complicated by severe cardiogenic shock (CS) or cardiac arrest (CA). METHODS AND RESULTS: From 2008 through 2017, 92 patients with AMI complicated by CS were treated with Impella. Survival varied according to clinical presentation. Patients in cardiogenic shock without CA had a 75% 30-day survival. Patients with CA and return of spontaneous circulation (ROSC) had a 43% survival and those with CA and ongoing cardio-pulmonary resuscitation (CPR) had a 6% 30-day survival. Age, pre-existing hypertension, coronary disease, ventilatory support and use of adrenergic agents were associated with worse prognosis. Complications were predominantly access site related. CONCLUSIONS: In this registry of patients with AMICS treated with Impella, hypertension and older age were found to be negatively predictive for survival. Patients without CA had the highest 30-day survival. In patients with ROSC, survival was strongly related to age and comorbidity. Patients with ongoing CPR had very high mortality.


Subject(s)
Heart Arrest/therapy , Heart-Assist Devices , Myocardial Infarction/therapy , Shock, Cardiogenic/therapy , Aged , Cardiopulmonary Resuscitation/adverse effects , Cardiopulmonary Resuscitation/statistics & numerical data , Female , Heart Arrest/etiology , Heart Arrest/mortality , Humans , Male , Middle Aged , Myocardial Infarction/complications , Myocardial Infarction/mortality , Proportional Hazards Models , Registries , Retrospective Studies , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality
8.
Thromb J ; 14: 9, 2016.
Article in English | MEDLINE | ID: mdl-27118929

ABSTRACT

BACKGROUND: In hereditary spherocytosis with severe anemia, splenectomy is a recommended treatment. However, the spleen carries an important role both in immune function and coagulation. The increased risk of bacterial infections associated with splenectomy is well known. Recently, hypercoagulation disorders have also been linked to splenectomy through loss of regulation of platelet activity, loss of filtering function and post-splenectomy thrombocytosis. CASE PRESENTATION: A 28 year-old smoking women who had previously undergone splenectomy due to hereditary spherocytosis with a moderate thrombocytosis (platelet count 553-635*10(9)/L), presented with recurrent episodes of pulmonary embolisms. Further examination by multimodality cardiac imaging demonstrated a giant chronic thrombus in the right ventricular outflow tract, which eventually had to be surgically removed. CONCLUSIONS: The present case highlights the increased risk of severe thromboembolic complications following therapeutic splenectomy in hereditary spherocytosis, and emphasis the important role of multimodality cardiac imaging in recurrent pulmonary embolism, diagnosing a giant chronic thrombus in the right ventricular outflow tract.

SELECTION OF CITATIONS
SEARCH DETAIL
...