Anal Chem ; 85(14): 6716-22, 2013 Jul 16.
Article in English | MEDLINE | ID: mdl-23802132

ABSTRACT

A linear pixel-based detector array, the IonCCD, is characterized for use under ambient conditions with thermal (<1 eV) positive ions derived from purified air and a 10 mCi (63)Ni foil. The IonCCD combined with a drift tube-ion mobility spectrometer permitted the direct detection of gas phase ions at atmospheric pressure and confirmed a limit of detection of 3000 ions/pixel/frame established previously in both the keV (1-2 keV) and the hyper-thermal (10-40 eV) regimes. Results demonstrate the "broad-band" application of the IonCCD over 10(5) orders in ion energy and over 10(10) in operating pressure. The Faraday detector of a drift tube for an ion mobility spectrometer was replaced with the IonCCD providing images of ion profiles over the cross-section of the drift tube. Patterns in the ion profiles were developed in the drift tube cross-section by control of electric fields between wires of Bradbury Nielson and Tyndall Powell shutter designs at distances of 1-8 cm from the detector. Results showed that ion beams formed in wire sets, retained their shape with limited mixing by diffusion and Coulombic repulsion. Beam broadening determined as 95 µm/cm for hydrated protons in air with moisture of ~10 ppmv. These findings suggest a value of the IonCCD in further studies of ion motion and diffusion of thermalized ions, enhancing computational results from simulation programs, and in the design or operation of ion mobility spectrometers.

2.
Rev Sci Instrum ; 81(3): 034104, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20370199

ABSTRACT

We have recently developed a soft-landing (SL) instrument that is capable of depositing ions onto substrates for preparative and developmental research of new materials using a laser ablation source. This instrument was designed with a custom drift tube and a split-ring ion optic for the isolation of selected ions. The drift tube allows for the separation and thermalization of ions formed after laser ablation through collisions with an inert bath gas. These collisions allow the ions to be landed at energies below 1 eV onto substrates. The split-ring ion optic is capable of directing ions toward the detector or a landing substrate for selected components. Experiments will be shown ablating Cu using an Nd:YAG (1064 and 532 nm) for cluster formation and landing onto a muscovite (mica) surface. The laser ablation of Cu in 8 Torr of He gas gives a spectrum that contains multiple peaks corresponding to Cu(n), Cu(n)O(m) clusters, and their corresponding isomers. Atomic force microscopy and drift tube measurements were performed to characterize the performance characteristics of the instrument.


Subject(s)
Ions , Materials Testing/instrumentation , Optics and Photonics/instrumentation , Algorithms , Aluminum Silicates , Copper , Helium , Lasers , Materials Testing/methods , Microscopy, Atomic Force , Optics and Photonics/methods , Oxygen