Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-32695757

ABSTRACT

Repeated non-diffuse optical imaging of the brain is difficult. This is due to the fact that the cranial bone is highly scattering and thus a strong optical barrier. Repeated craniotomies increase the risk of complications and may disrupt the biological systems being imaged. We previously introduced a potential solution in the form of a transparent ceramic cranial implant called the Window to the Brain (WttB) implant. This implant is made of nanocrystalline Yttria-Stabilized Zirconia (nc-YSZ), which possesses the requisite mechanical strength to serve as a permanent optical access window in human patients. In this present study, we demonstrate repeated brain imaging of n = 5 mice using both OCT and LSI across the WttB implant over 4 weeks. The main objectives are to determine if the WttB implant allows for chronic OCT imaging, and to shed further light on the question of whether optical access provided by the WttB implant remains stable over this duration in the body. The Window to the Brain implant allowed for stable repeated imaging of the mouse brain with Optical Coherence Tomography over 28 days, without loss of signal intensity. Repeated Laser Speckle Imaging was also possible over this timeframe, but signal to noise ratio and the sharpness of vessels in the images decreased with time. This can be partially explained by elevated blood flow during the first imaging session in response to trauma from the surgery, which was also detected by OCT flow imaging. These results are promising for long-term optical access through the WttB implant, making feasible chronic in vivo studies in multiple neurological models of brain disease.

2.
J Biomed Mater Res B Appl Biomater ; 108(3): 709-716, 2020 04.
Article in English | MEDLINE | ID: mdl-31172661

ABSTRACT

The "Window to the Brain" is a transparent cranial implant under development, based on nanocrystalline yttria-stabilized zirconia (nc-YSZ) transparent ceramic material. Previous work has demonstrated the feasibility of this material to facilitate brain imaging over time, but the long-term stability of the material over decades in the body is unknown. In this study, the low-temperature degradation (LTD) of nc-YSZ of 3, 6, and 8 mol % yttria is compared before and after accelerated ageing treatments following ISO standards for assessing the ageing resistance of zirconia ceramics. After 100 hr of accelerated ageing (equivalent to many decades of ageing in the body), the samples do not show any signs of phase transformation to monoclinic by X-ray diffraction and micro-Raman spectroscopy. Moreover, the mechanical hardness of the samples did not decrease, and changes in optical transmittance from 500 to 1000 nm due to ageing treatments was minimal (below 3% for all samples), and unlikely to be due to phase transformation of surface crystals to monoclinic. These results indicate the nc-YSZ has excellent ageing resistance and can withstand long-term implantation conditions without exhibiting LTD.


Subject(s)
Ceramics/chemistry , Nanoparticles/chemistry , Prostheses and Implants , Yttrium/chemistry , Zirconium/chemistry , Ceramics/metabolism , Crystallization , Hardness , Hot Temperature , Humans , Materials Testing , Nanoparticles/metabolism , Phase Transition , Pressure , Skull , Surface Properties , X-Ray Diffraction , Yttrium/metabolism , Zirconium/metabolism
3.
Biomed Opt Express ; 10(7): 3369-3379, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31467783

ABSTRACT

We report on the enhanced optical transmittance in the NIR wavelength range (900 to 2400 nm) offered by a transparent Yttria-stabilized zirconia (YSZ) implant coupled with optical clearing agents (OCAs). The enhancement in optical access to the brain is evaluated upon comparing ex-vivo transmittance measurements of mice native skull and the YSZ cranial implant with scalp and OCAs. An increase in transmittance of up to 50% and attenuation lengths of up to 2.4 mm (i.e., a five-fold increase in light penetration) are obtained with the YSZ implant and the OCAs. The use of this ceramic implant and the biocompatible optical clearing agents offer attractive features for NIR optical techniques for brain theranostics.

4.
Lasers Surg Med ; 51(10): 920-932, 2019 12.
Article in English | MEDLINE | ID: mdl-31236997

ABSTRACT

BACKGROUND AND OBJECTIVE: Microcirculation plays a critical role in physiologic processes and several disease states. Laser speckle imaging (LSI) is a full-field, real-time imaging technique capable of mapping microvessel networks and providing relative flow velocity within the vessels. In this study, we demonstrate that LSI combine with multispectral reflectance imaging (MSRI), which allows for distinction between veins and arteries in the vascular flow maps produced by LSI. We apply this combined technique to mouse cerebral vascular network in vivo, comparing imaging through the skull, to the dura mater and brain directly through a craniectomy, and through a transparent cranial "Window to the Brain" (WttB) implant. STUDY DESIGN/MATERIALS AND METHODS: The WttB implant used in this study is made of a nanocrystalline Yttria-Stabilized-Zirconia ceramic. MSRI was conducted using white-light illumination and filtering the reflected light for 560, 570, 580, 590, 600, and 610 nm. LSI was conducted using an 810 nm continuous wave near-infrared laser with incident power of 100 mW, and the reflected speckle pattern was captured by a complementary metal-oxide-semiconductor (CMOS) camera. RESULTS: Seven vessel branches were analyzed and comparison was made between imaging through the skull, craniectomy, and WttB implant. Through the skull, MSRI did not detect any vessels, and LSI could not image microvessels. Imaging through the WttB implant, MSRI was able to identify veins versus arteries, and LSI was able to image microvessels with only slightly higher signal-to-noise ratio and lower sharpness than imaging the brain through a craniectomy. CONCLUSIONS: This study demonstrates the ability to perform MSRI-LSI across a transparent cranial implant, to allow for cerebral vascular networks to be mapped, including microvessels. These images contain additional information such as vein-artery separation and relative blood flow velocities, information which is of value scientifically and medically. The WttB implant provides substantial improvements over imaging through the murine cranial bone, where microvessels are not visible and MSRI cannot be performed. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.


Subject(s)
Brain/blood supply , Microvessels/diagnostic imaging , Optical Imaging/methods , Prostheses and Implants , Prosthesis Implantation , Skull/surgery , Animals , Blood Flow Velocity , Brain/diagnostic imaging , Brain/physiology , Ceramics , Male , Mice , Microcirculation/physiology , Optical Imaging/instrumentation , Spectroscopy, Near-Infrared , Yttrium , Zirconium
5.
Microvasc Res ; 122: 52-59, 2019 03.
Article in English | MEDLINE | ID: mdl-30414869

ABSTRACT

Since of its introduction in 1980s, laser speckle imaging has become a powerful tool in flow imaging. Its high performance and low cost made it one of the preferable imaging methods. Initially, speckle contrast measurements were the main algorithm for analyzing laser speckle images in biological flows. Speckle contrast measurements, also referred as Laser Speckle Contrast Imaging (LSCI), use statistical properties of speckle patterns to create mapped image of the blood vessels. In this communication, a new method named Laser Speckle Optical Flow Imaging (LSOFI) is introduced. This method uses the optical flow algorithms to calculate the apparent motion of laser speckle patterns. The differences in the apparent motion of speckle patterns are used to identify the blood vessels from surrounding tissue. LSOFI has better spatial and temporal resolution compared to LSCI. This higher spatial resolution enables LSOFI to be used for autonomous blood vessels detection. Furthermore, Graphics Processing Unit (GPU) based LSOFI can be used for quasi real time imaging.


Subject(s)
Algorithms , Image Interpretation, Computer-Assisted/methods , Laser-Doppler Flowmetry/methods , Optical Imaging/methods , Skull/blood supply , Animals , Blood Flow Velocity , Mice , Models, Cardiovascular , Predictive Value of Tests , Regional Blood Flow , Time Factors
6.
Biomed Opt Express ; 9(10): 4879-4892, 2018 Oct 01.
Article in English | MEDLINE | ID: mdl-30319909

ABSTRACT

Laser speckle imaging (LSI) of mouse cerebral blood flow was compared through a transparent nanocrystalline yttria-stabilized zirconia (nc-YSZ) cranial implant over time (at days 0, 14, and 28, n = 3 mice), and vs. LSI through native skull (at day 60, n = 1 mouse). The average sharpness of imaged vessels was found to remain stable, with relative change in sharpness under 7.69% ± 1.2% over 28 days. Through-implant images of vessels at day 60 appeared sharper and smaller on average, with microvessels clearly visible, compared to through-skull images where vessels appeared blurred and distorted. These results suggest that long-term imaging through this implant is feasible.

SELECTION OF CITATIONS
SEARCH DETAIL
...