Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 92
Filter
1.
HIV Med ; 13(7): 436-8, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22276852

ABSTRACT

OBJECTIVE: A Swiss nonoccupational post-exposure prophylaxis (NPEP) source-tracing study successfully reduced unnecessary NPEP prescriptions by recruiting and testing source partners of unknown HIV serostatus. The Victorian NPEP Service in Australia attempted to replicate this study with the addition of HIV rapid testing and a mobile service. METHODS: Patients presenting to two busy NPEP sites who reported a source partner of unknown HIV status were routinely asked if their source could be traced. If the exposed person indicated that their source partner was traceable they were asked to contact them and discuss the possibility of having an HIV test. RESULTS: No sources were enrolled and the study was terminated. CONCLUSION: We hypothesize that there are a number of differences between Australia and Switzerland that make source tracing unfeasible in Australia.


Subject(s)
Anti-HIV Agents/supply & distribution , Contact Tracing/methods , Drug Prescriptions/statistics & numerical data , HIV Seropositivity/diagnosis , Post-Exposure Prophylaxis/supply & distribution , Anti-HIV Agents/economics , Anti-HIV Agents/therapeutic use , Australia/epidemiology , Contact Tracing/economics , Cost-Benefit Analysis , Feasibility Studies , Female , HIV Seropositivity/drug therapy , HIV Seropositivity/economics , HIV Seropositivity/epidemiology , Humans , Male , Patient Selection , Post-Exposure Prophylaxis/economics , Sexual Partners , Switzerland/epidemiology , Victoria/epidemiology
2.
Vox Sang ; 97(4): 309-16, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19682349

ABSTRACT

BACKGROUND: Laboratories screening for blood-borne virus infections in blood and blood products are required by international standards and guidelines to ensure that their testing processes remain within control. An effective means of ensuring this aim is through participation in a quality control programme. Analyses of results from a quality control (QC) programme conducted for the Abbott PRISM (PRISM) assays are reported. MATERIALS AND METHODS: Laboratories participating in the National Serology Reference Laboratory, Australia's PRISM QC programme were provided with aliquots of a multimarker QC sample which were tested regularly in each PRISM subchannel. Test results were submitted to a single database using an Internet-based QC monitoring system, EDCNet. The QC test results submitted between 15 October 2001 and 5 March 2006 for each PRISM instrument and each lot of PRISM reagent were analysed to determine the imprecision and bias in each test system. RESULTS: A total of 157,404 test results from approximately 47,000 test runs submitted into the EDCNet database were analysed. Six batches of the multimarker QC samples were tested in 454 PRISM reagent lots. The coefficient of variation of QC sample test results ranged from 9.17 to 15.83%, 8.29 to 9.44%, 10.50 to 15.38% and 7.05 to 10.32% when tested in the PRISM anti-hepatitis C virus, anti-human immunodeficiency virus, anti-human T-cell lymphotrophic virus and hepatitis B surface antigen assays, respectively. Analysis of QC test results reported from testing in the anti-HTLV assay detected one lot of reagent (10572HN00) which was identified to be an outlier using Tukey's filter. DISCUSSION: Analysis of test results of an external QC sample can be used as a statistical process control through ongoing measurement of imprecision. When laboratories test the same QC sample in the same assay and submit test results to a single database, the results can be compared and a measure of bias can be calculated. The resulting QC programme can offer detection of unexpected variation in the testing processes and the source of variation investigated.


Subject(s)
Blood Donors , Blood-Borne Pathogens , Donor Selection/standards , Quality Control , Safety Management , Virus Diseases/blood , Virus Diseases/prevention & control , Donor Selection/methods , Female , Humans , Male , Practice Guidelines as Topic
4.
J Clin Microbiol ; 41(1): 227-36, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12517853

ABSTRACT

Genotypic antiretroviral testing is now widely used for the management of patients who are undergoing antiretroviral therapy for human immunodeficiency virus infection. The assays are complex, and there is considerable potential for variation between laboratories. Informative and ongoing quality assessment programs (QAPs) which address all aspects of testing are required. The panel distribution of clinical material is a critical component of QAPs. We report on the results and data from a recent panel. Four cryopreserved plasma samples from treated donors were distributed to nine laboratories. Three laboratories performed testing by commercial assays, and six laboratories used in-house assays, with one laboratory reporting results from two in-house assays. There was complete concordance between results for 95.9% of the nucleotide sequence and 94.5% of the amino acid sequence. Despite this overall high level of concordance, the degree of concordance at drug resistance mutation (DRM) sites when DRMs were present was considerably less (38% of DRM sites). Consequently, only 3 of the 10 methods reported 100% of DRMs as present. This elevated discrepancy rate is almost certainly a result of variability in the identification of mixtures of nucleotides (mixtures) at any site within the sequence. In addition, laboratories differed in the number of codons in the reverse transcriptase gene that were sequenced and their ability to amplify all samples. This panel distribution demonstrated a requirement for laboratory participation in ongoing QAPs and the optimization of assays with standards that contain mixtures.


Subject(s)
Drug Resistance, Viral/genetics , HIV Reverse Transcriptase/genetics , Anti-HIV Agents/therapeutic use , Antiretroviral Therapy, Highly Active , Environmental Monitoring , Genotype , HIV Infections/drug therapy , HIV Infections/virology , HIV-1/drug effects , HIV-1/enzymology , Humans , Mutation , Sequence Analysis, DNA
5.
Vox Sang ; 81(1): 6-11, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11520409

ABSTRACT

BACKGROUND AND OBJECTIVES: In Australia, a policy of deferring donors who have lived in the UK for longer than 6 months between 1980 and 1996 has been instituted to reduce the theoretical risk of transmitting variant Creutzfeldt-Jakob disease (vCJD) through the blood supply. The objective of this report was to refine estimates of the possible risks and benefits of donor-deferral strategies that are aimed at avoiding transmission of vCJD. MATERIALS AND METHODS: Estimates of the effect of donor deferral on the blood supply in Australia were based on a 1998 survey of blood donors. The number of donations from donors potentially infected with vCJD and excluded by donor deferral was estimated based on published estimates of the size of the vCJD epidemic in the UK and assuming that the risk of vCJD in Australian blood donors was proportional to the time lived in the UK between 1980 and 1996. The possible increased number of blood donations that were infected with human immunodeficiency virus (HIV), hepatitis C virus (HCV) or hepatitis B virus (HBV) and made during a window period (as a result of increased donations from first-time donors) was estimated using published methods. RESULTS: A strategy of deferring donations in Australia from people who have lived in the UK for 6 months or longer, between 1980 and 1996, was estimated to result in exclusion of 5.3% of all blood donations, corresponding to 50 100 donations in 1998. It was estimated that the annual number of blood donations made by donors potentially infected with vCJD is 1.15 (range 0.02--31.1, based on the uncertainty in the UK prevalence estimate). Donor deferral was estimated to remove 0.92 (range 0.02--25.1) of these donations. Replacement of 33%, 50% and 100% of excluded donations by donations from first-time donors, was estimated to result in an increase of 0.0010, 0.0019 and 0.0044, respectively, of HIV-infected donations per year donated during the window period; in an increase of 0.021, 0.038 and 0.089, respectively, of HCV-infected donations per year; and in an increase of 0.18, 0.33 and 0.76, respectively, of HBV-infected donations per year. CONCLUSIONS: The large uncertainties involved in these analyses mean that estimates must be interpreted cautiously, but the data does suggest that donor deferral may exclude more donations from donors potentially infected with vCJD than the corresponding increase, caused by donor replacement, of window-period donations possibly infected with HIV, HCV or HBV.


Subject(s)
Blood Donors , Creutzfeldt-Jakob Syndrome/blood , Creutzfeldt-Jakob Syndrome/transmission , Australia/epidemiology , Blood Banks/standards , Creutzfeldt-Jakob Syndrome/prevention & control , HIV Infections/prevention & control , HIV Infections/transmission , Hepatitis B/prevention & control , Hepatitis B/transmission , Humans , Incidence , Population Surveillance , Residence Characteristics , Risk Factors , United Kingdom , Blood Banking/methods
6.
J Clin Microbiol ; 38(11): 4015-20, 2000 Nov.
Article in English | MEDLINE | ID: mdl-11060062

ABSTRACT

This study determined the proficiencies of laboratories measuring human immunodeficiency virus type 1 (HIV-1) viral loads and the accuracies of two assays used for HIV-1 viral load measurement in Australia and investigated the variability of the new versions of these assays. Quality assessment program panels containing (i) dilutions of HIV-1 subtype B, (ii) replicates of identical samples of HIV-1 subtype B, and (iii) samples of subtype E and B were tested by laboratories. Total variability (within and between laboratories) was tested with quality control samples. The coefficients of variation (CVs) for the Roche AMPLICOR HIV-1 MONITOR version (v) 1.0 and Chiron Quantiplex bDNA 2.0 assays ranged from 53 to 87% and 22 to 31%, respectively. The widespread occurrence of invalid runs with the AMPLICOR HIV-1 MONITOR 1.0 assay was identified. The CVs of the new versions of the assays were 82 to 86% for the AMPLICOR HIV-1 MONITOR v 1.5 assay and 16 to 23% for the Quantiplex bDNA 3.0 assay. For virus dilution samples, all but 5 of 19 laboratories obtained results within 2 standard deviations of the mean. The Quantiplex bDNA 2.0 assay reported values lower than those reported by the AMPLICOR HIV-1 MONITOR version 1.0 assay for samples containing HIV-1 subtype B, whereas the reverse was true for subtype E. Identification and resolution of the problem of invalid runs markedly improved the quality of HIV-1 viral load testing. The variability observed between laboratories and between assays, even the most recent versions, dictates that monitoring of viral load in an individual should always be by the same laboratory and by the same assay. Results for an individual which differ by less than 0.5 log(10) HIV-1 RNA copy number/ml should not be considered clinically significant.


Subject(s)
HIV Infections/virology , HIV-1/isolation & purification , HIV-1/physiology , Laboratories/standards , Viral Load , Australia , Humans , Quality Control , RNA, Viral/blood , Reagent Kits, Diagnostic , Reproducibility of Results
7.
AIDS ; 13(1): 133-4, 1999 Jan 14.
Article in English | MEDLINE | ID: mdl-10207555
8.
J Virol Methods ; 82(2): 113-8, 1999 Oct.
Article in English | MEDLINE | ID: mdl-10894627

ABSTRACT

Immunoassays such as particle agglutination assays, rapid tests and western or line blots are scored or read subjectively. These readings display intra- and inter-reader variability, as well as intra- and inter-laboratory variability. In the present study the consistency of scoring was assessed between readers both within and between two groups of scientists using the Serodia anti-HIV particle agglutination assay as an example of an assay scored subjectively. An anti-HIV positive sample in eight serial dilutions made to yield a full range of results expected for the assay was presented 12 times (96 test wells). Each dilution was placed randomly in a plate and tested with the Serodia anti-HIV particle agglutination assay then photographed. Participants in the two groups each scored the photographed plate independently and twice, 2 h apart. Each well was assigned a status (the consensus result of the four most experienced Australian readers) and each participant's results were compared with this status. The average percentage of wells assessed as 'correct' for the Group A participants was 86% (range 56-98%) and for the Group B participants was 67% 'correct' (range 46-88%). In general, strongly positive and negative wells were scored 'correctly'. The highest variations between scores were seen in the borderline positive dilutions +/- region. A quality assessment program based on the method used to obtain these results will be instituted in order to improve the consistency of scoring assays read subjectively.


Subject(s)
AIDS Serodiagnosis/standards , Agglutination Tests/standards , Immunoassay/standards , Agglutination Tests/instrumentation , Humans , Immunoassay/instrumentation , Observer Variation , Photography , Quality Control , Reproducibility of Results , Time Factors
11.
Expert Opin Investig Drugs ; 6(8): 965-83, 1997 Aug.
Article in English | MEDLINE | ID: mdl-15989656

ABSTRACT

Increased knowledge of the human immunodeficiency virus (HIV) and the infection it causes in humans has resulted in an enormous expansion in the understanding of viral parameters and host changes. HIV is a virus which mutates readily and rapidly, presenting many challenges to assay developers, and monitors of therapy and drug-resistance. Prolific viral replication at all the stages of the disease means that an accurate assessment of viral burden, viral load and changes to immune system markers is essential for effective clinical management and treatment. In the present review we have summarised current opinion on the kinetics of HIV infection and the pathogenesis of the disease it causes, and have provided a background to the evolution of HIV assays. Sensitivities and specificities of assays used for anti-HIV and HIV detection have improved, and new assays have been developed employing novel molecular techniques, which are being applied to meet continually evolving demands for more sensitive measurement of an increasing number of parameters. The future of HIV testing is also considered in the light of new knowledge concerning virus dynamics in vivo, the likelihood of the emergence of new subtypes and the changing approach to therapy. Assays will be, on the whole, used to quantify virus and to measure the host reactions to infection, often in the presence of antivirals. Thus, extreme sensitivity and specificity will be required.

13.
Article in English | MEDLINE | ID: mdl-7882108

ABSTRACT

The performance of four enzyme immunoassays, manufactured by Abbott, Diagnostics Pasteur, Genetic Systems, and Organon Teknika, for the combined detection of anti-human immunodeficiency virus type 1 (HIV-1) and anti-HIV-2, was examined in a multisite evaluation. The collaborative efforts of 7 Australian Red Cross Blood Transfusion and 12 Australian Public Health Laboratories minimized potential biases in data by providing large numbers of anti-HIV-1-negative and -positive samples. Sensitivity was estimated using samples that were positive for anti-HIV-1 from individuals known to be infected and seroconversion samples. Sensitivity estimates in the four assays were 99.71, 99.94, 99.49, and 99.68%, respectively. Specificity was measured using fresh, sequential blood donations and samples with previous false-positive reactions in other assays. Specificity estimates from blood donations were 99.92, 99.46, 99.67, and 99.85%, respectively. The data were analyzed further using the delta statistic, which distinguishes the performance of assays of similar sensitivity and specificity by providing a measure of how well results in a population of positive or negative samples are removed from the assay's cutoff value.


Subject(s)
HIV Antibodies/analysis , HIV Infections/diagnosis , HIV-1/immunology , HIV-2/immunology , Immunoenzyme Techniques , Australia , False Positive Reactions , HIV Seronegativity/immunology , HIV Seropositivity/immunology , Humans , Predictive Value of Tests , Reagent Kits, Diagnostic , Sensitivity and Specificity
15.
Aust N Z J Psychiatry ; 27(4): 718, 1993 Dec.
Article in English | MEDLINE | ID: mdl-8135699
16.
J Virol Methods ; 45(1): 83-91, 1993 Nov.
Article in English | MEDLINE | ID: mdl-8270658

ABSTRACT

The performance of eight anti-HTLV-I enzyme immunoassays (EIAs) and one particle agglutination assay was compared with respect to sensitivity, specificity and delta values, by testing a panel containing 99 anti-HTLV-I positive and 126 anti-HTLV-I negative samples which had been characterised by western blot and some by radioimmunoprecipitation assay. The estimated sensitivities produced by these assays ranged between 99% and 100% and estimated specificities were between 95.2% and 100%. The performance of the EIAs was further differentiated by using the delta value which measures the ability of an assay to separate the positive and negative populations from the cutoff value. A delta value could not be calculated for the particle agglutination assay (Serodia) because the test readings were not quantitative. The EIAs most likely to correctly identify anti-HTLV-I positive and anti-HTLV-I negative samples included the Cambridge Biotech, Dupont, Genetic Systems and Olympus assays. Our findings suggest that there may be some difficulty in correctly identifying anti-HTLV-I negative samples using the Abbott, Cellular Products Incorporated (CPI), Coulter and Diagnostic Biotechnology assays. The Serodia assay produced comparable sensitivity and specificity to the eight EIAs.


Subject(s)
Antibodies, Viral/blood , Human T-lymphotropic virus 1/isolation & purification , Agglutination Tests , Enzyme-Linked Immunosorbent Assay , Humans , Immunoenzyme Techniques , Sensitivity and Specificity
17.
Exp Gerontol ; 28(4-5): 329-40, 1993.
Article in English | MEDLINE | ID: mdl-8224032

ABSTRACT

Studies from a number of laboratories demonstrate a biphasic change in beta adrenergic regulation of hepatic glycogenolysis over the life span of the male rat. The beta adrenergic response is prominent in immature animals, declines rapidly during subsequent development to a minimum by the time of young adulthood, and then reemerges during postmaturational development. Age changes in beta adrenergic-responsive adenylate cyclase activity follow a "U"-shaped curve similar to that described by changes in liver glycogenolytic responsiveness during aging. Developmental and postmaturational changes in beta adrenergic-sensitive adenylate cyclase activation are related to parallel alterations in the density of beta adrenergic receptors and also to functional changes in nonreceptor components of the enzyme. The prevailing view that catecholamines stimulate hepatic glycogenolysis by an alpha adrenergic receptor-mediated, cyclic AMP-independent mechanism is based almost entirely on evidence from young adult male rats. We propose that current concepts of alpha adrenergic-responsive liver glycogenolysis underestimate a physiological role for beta adrenergic responsiveness over the majority of the life span.


Subject(s)
Aging/physiology , Liver Glycogen/metabolism , Liver/metabolism , Receptors, Adrenergic, beta/physiology , Adenylyl Cyclases/physiology , Animals , Female , Liver/enzymology , Male , Rats , Rats, Inbred F344 , Rats, Wistar
18.
Med J Aust ; 159(1): 29-31, 1993 Jul 05.
Article in English | MEDLINE | ID: mdl-8316110

ABSTRACT

OBJECTIVE: To describe the clinical and laboratory features of human T-lymphotropic virus type I (HTLV-I) associated myelopathy in an immigrant from the Seychelles. CLINICAL FEATURES: A slowly progressive myelopathy has been recently diagnosed in a 64-year-old woman who emigrated to Australia from the Seychelles in 1957. Sphincter disturbance and back pain were the first manifestations, followed by gait disturbance. Neurophysiological investigation supported the clinical diagnosis of a myelopathy and radiological investigations revealed no structural cause. Serum antibodies to HTLV-I were detected by enzyme-linked particle agglutination and the presence of antibodies to individual HTLV-I gene products in the serum was confirmed by western blot. The virus was detected in a culture of the patient's peripheral blood mononuclear cells by antigen capture assay and by sequencing a polymerase chain reaction product amplified from the env gene. INTERVENTION AND OUTCOME: The patient was advised of the nature and prognosis of her illness. Oral corticosteroids were tried without benefit. CONCLUSIONS: The prevalence of HTLV-I infection is low in Australia although it may be endemic in some Aboriginal communities. Most infections are asymptomatic but the chronic neurological disease associated with HTLV-I infection has now been shown to exist in this country. HTLV-I infection should be considered in the aetiology of myelopathy without another obvious cause.


Subject(s)
Paraparesis, Tropical Spastic/ethnology , Australia , Base Sequence , DNA, Viral/analysis , Emigration and Immigration , Female , Human T-lymphotropic virus 1/classification , Human T-lymphotropic virus 1/genetics , Humans , Middle Aged , Molecular Sequence Data , Seychelles/ethnology
19.
Med J Aust ; 158(12): 810-2, 1993 Jun 21.
Article in English | MEDLINE | ID: mdl-8326890

ABSTRACT

OBJECTIVE: To prospectively study occupational exposures to human immunodeficiency virus (HIV) and other blood-borne pathogens. DESIGN AND SETTING: Detailed clinical information was collected and follow-up was performed on all health care workers with occupational exposures to potentially infected substances at Fairfield Infectious Diseases Hospital during the period January 1985 to September 1991. RESULTS: There were 230 occupational exposures reported. One hundred and forty-one were considered "significant" or "potentially significant"; these involved exposure (or the potential for exposure) to blood or body fluids by the parenteral route or contamination of non-intact skin or mucous membranes. Needle/syringe assemblies accounted for 59% of the "significant" injuries, "butterfly" needles for 21% and lancets for 8%. "Butterfly" needles were over-represented relative to their degree of use. Seventy-seven of the 230 exposures were HIV-related and 27 of these were considered "significant". The number of HIV positive patients attending the hospital increased progressively over the survey period but the rate of HIV-related exposures fell during that time. After 1988, 13 individuals with "significant" exposure to HIV received a six-week prophylactic course of zidovudine. No health care workers seroconverted for HIV, hepatitis B or hepatitis C during the survey period. CONCLUSIONS: The risk of acquiring HIV (and other blood-borne diseases) through occupational exposure is very low and this risk can be further reduced by adopting safe work practices.


Subject(s)
HIV Infections/transmission , Hepatitis B/transmission , Hepatitis C/transmission , Medical Staff, Hospital , Nursing Staff, Hospital , Occupational Exposure/statistics & numerical data , Blood , Communicable Diseases , Eye , Follow-Up Studies , Hospitals, Special , Humans , Mouth Mucosa , Needles/statistics & numerical data , Needlestick Injuries/complications , Needlestick Injuries/epidemiology , Occupational Exposure/adverse effects , Prospective Studies , Punctures/adverse effects , Punctures/statistics & numerical data , Sputum , Urine , Victoria/epidemiology
20.
J Acquir Immune Defic Syndr (1988) ; 6 Suppl 1: S24-8, 1993.
Article in English | MEDLINE | ID: mdl-8426298

ABSTRACT

Testing for antibody to human immunodeficiency virus (HIV) in Australia is subjected to continual monitoring for ensuring that the performance of tests in the field is reliable and provides accurate data on HIV tests and testing that are unique to Australia.


Subject(s)
HIV Antibodies/blood , Immunoassay/standards , Australia , Humans , Quality Control
SELECTION OF CITATIONS
SEARCH DETAIL
...