Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 66(5): 055016, 2021 02 20.
Article in English | MEDLINE | ID: mdl-33373979

ABSTRACT

Synchrotron Radiotherapy (SyncRT) is a preclinical radiation treatment which delivers synchrotron x-rays to cancer targets. SyncRT allows for novel treatments such as Microbeam Radiotherapy, which has been shown to have exceptional healthy tissue sparing capabilities while maintaining good tumour control. Veterinary trials in SyncRT are anticipated to take place in the near future at the Australian Synchrotron's Imaging and Medical Beamline (IMBL). However, before veterinary trials can commence, a computerised treatment planning system (TPS) is required, which can quickly and accurately calculate the synchrotron x-ray dose through patient CT images. Furthermore, SyncRT TPS's must be familiar and intuitive to radiotherapy planners in order to alleviate necessary training and reduce user error. We have paired an accurate and fast Monte Carlo (MC) based SyncRT dose calculation algorithm with EclipseTM, the most widely implemented commercial TPS in the clinic. Using EclipseTM, we have performed preliminary SyncRT trials on dog cadavers at the IMBL, and verified calculated doses against dosimetric measurement to within 5% for heterogeneous tissue-equivalent phantoms. We have also performed a validation of the TPS against a full MC simulation for constructed heterogeneous phantoms in EclipseTM, and showed good agreement for a range of water-like tissues to within 5%-8%. Our custom EclipseTM TPS for SyncRT is ready to perform live veterinary trials at the IMBL.


Subject(s)
Algorithms , Dog Diseases/radiotherapy , Neoplasms/veterinary , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Synchrotrons/instrumentation , Animals , Cadaver , Computer Simulation , Dogs , Monte Carlo Method , Neoplasms/radiotherapy , Radiometry , Radiotherapy Dosage
2.
Phys Med ; 77: 64-74, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32791426

ABSTRACT

Experimental measurement of Synchrotron Radiotherapy (SyncRT) doses is challenging, especially for Microbeam Radiotherapy (MRT), which is characterised by very high dynamic ranges with spatial resolutions on the micrometer scale. Monte Carlo (MC) simulation is considered a gold standard for accurate dose calculation in radiotherapy, and is therefore routinely relied upon to produce verification data. We present a MC model for Australian Synchrotron's Imaging and Medical Beamline (IMBL), which is capable of generating accurate dosimetry data to inform and/or verify SyncRT experiments. Our MC model showed excellent agreement with dosimetric measurement for Synchrotron Broadbeam Radiotherapy (SBBR). Our MC model is also the first to achieve validation for MRT, using two methods of dosimetry, to within clinical tolerances of 5% for a 20×20 mm2 field size, except for surface measurements at 5 mm depth, which remained to within good agreement of 7.5%. Our experimental methodology has allowed us to control measurement uncertainties for MRT doses to within 5-6%, which has also not been previously achieved, and provides a confidence which until now has been lacking in MRT validation studies. The MC model is suitable for SyncRT dose calculation of clinically relevant field sizes at the IMBL, and can be extended to include medical beamlines at other Synchrotron facilities as well. The presented MC model will be used as a validation tool for treatment planning dose calculation algorithms, and is an important step towards veterinary SyncRT trials at the Australian Synchrotron.


Subject(s)
Radiometry , Synchrotrons , Australia , Monte Carlo Method , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...