1.
Micromachines (Basel) ; 15(6)2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38930760

ABSTRACT

Microfluidic devices promise to overcome the limitations of conventional hemodialysis and oxygenation technologies by incorporating novel membranes with ultra-high permeability into portable devices with low blood volume. However, the characteristically small dimensions of these devices contribute to both non-physiologic shear that could damage blood components and laminar flow that inhibits transport. While many studies have been performed to empirically and computationally study hemolysis in medical devices, such as valves and blood pumps, little is known about blood damage in microfluidic devices. In this study, four variants of a representative microfluidic membrane-based oxygenator and two controls (positive and negative) are introduced, and computational models are used to predict hemolysis. The simulations were performed in ANSYS Fluent for nine shear stress-based parameter sets for the power law hemolysis model. We found that three of the nine tested parameters overpredict (5 to 10×) hemolysis compared to empirical experiments. However, three parameter sets demonstrated higher predictive accuracy for hemolysis values in devices characterized by low shear conditions, while another three parameter sets exhibited better performance for devices operating under higher shear conditions. Empirical testing of the devices in a recirculating loop revealed levels of hemolysis significantly lower (<2 ppm) than the hemolysis ranges observed in conventional oxygenators (>10 ppm). Evaluating the model's ability to predict hemolysis across diverse shearing conditions, both through empirical experiments and computational validation, will provide valuable insights for future micro ECMO device development by directly relating geometric and shear stress with hemolysis levels. We propose that, with an informed selection of hemolysis parameters based on the shear ranges of the test device, computational modeling can complement empirical testing in the development of novel high-flow blood-contacting microfluidic devices, allowing for a more efficient iterative design process. Furthermore, the low device-induced hemolysis measured in our study at physiologically relevant flow rates is promising for the future development of microfluidic oxygenators and dialyzers.

2.
Nat Med ; 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38871975

ABSTRACT

Microsatellite stable metastatic colorectal cancer (MSS mCRC; mismatch repair proficient) has previously responded poorly to immune checkpoint blockade. Botensilimab (BOT) is an Fc-enhanced multifunctional anti-cytotoxic T-lymphocyte-associated protein 4 (CTLA-4) antibody designed to expand therapy to cold/poorly immunogenic solid tumors, such as MSS mCRC. BOT with or without balstilimab (BAL; anti-PD-1 antibody) is being evaluated in an ongoing expanded phase 1 study. The primary endpoint is safety and tolerability, which was evaluated separately in the dose-escalation portion of the study and in patients with MSS mCRC (using combined dose-escalation/dose-expansion data). Secondary endpoints include investigator-assessed RECIST version 1.1-confirmed objective response rate (ORR), disease control rate (DCR), duration of response (DOR) and progression-free survival (PFS). Here we present outcomes in 148 heavily pre-treated patients with MSS mCRC (six from the dose-escalation cohort; 142 from the dose-expansion cohort) treated with BOT and BAL, 101 of whom were considered response evaluable with at least 6 months of follow-up. Treatment-related adverse events (TRAEs) occurred in 89% of patients with MSS mCRC (131/148), most commonly fatigue (35%, 52/148), diarrhea (32%, 47/148) and pyrexia (24%, 36/148), with no grade 5 TRAEs reported and a 12% discontinuation rate due to a TRAE (18/148; data fully mature). In the response-evaluable population (n = 101), ORR was 17% (17/101; 95% confidence interval (CI), 10-26%), and DCR was 61% (62/101; 95% CI, 51-71%). Median DOR was not reached (NR; 95% CI, 5.7 months-NR), and median PFS was 3.5 months (95% CI, 2.7-4.1 months), at a median follow-up of 10.3 months (range, 0.5-42.6 months; data continuing to mature). The combination of BOT plus BAL demonstrated a manageable safety profile with no new immune-mediated safety signals and encouraging clinical activity with durable responses. ClinicalTrials.gov identifier: NCT03860272 .

4.
Cancer Res Commun ; 3(12): 2572-2584, 2023 12 19.
Article in English | MEDLINE | ID: mdl-38115208

ABSTRACT

PURPOSE: This phase Ib open-label, multicenter, platform study (NCT02646748) explored safety, tolerability, and preliminary activity of itacitinib (Janus kinase 1 inhibitor) or parsaclisib (phosphatidylinositol 3-kinase δ inhibitor) in combination with pembrolizumab [programmed death-1 (PD-1) inhibitor]. EXPERIMENTAL DESIGN: Patients with advanced or metastatic solid tumors with disease progression following all available therapies were enrolled and received itacitinib (Part 1 initially 300 mg once daily) or parsaclisib (Part 1 initially 10 mg once daily; Part 2 all patients 0.3 mg once daily) plus pembrolizumab (200 mg every 3 weeks). RESULTS: A total of 159 patients were enrolled in the study and treated with itacitinib (Part 1, n = 49) or parsaclisib (Part 1, n = 83; Part 2, n = 27) plus pembrolizumab. The maximum tolerated/pharmacologically active doses were itacitinib 300 mg once daily and parsaclisib 30 mg once daily. Most common itacitinib treatment-related adverse events (TRAE) were fatigue, nausea, and anemia. Most common parsaclisib TRAEs were fatigue, nausea, diarrhea, and pyrexia in Part 1, and fatigue, maculopapular rash, diarrhea, nausea, and pruritus in Part 2. In patients receiving itacitinib plus pembrolizumab, four (8.2%) achieved a partial response (PR) in Part 1. Among patients receiving parsaclisib plus pembrolizumab, 5 (6.0%) achieved a complete response and 9 (10.8%) a PR in Part 1; 5 of 27 (18.5%) patients in Part 2 achieved a PR. CONCLUSIONS: Although combination of itacitinib or parsaclisib with pembrolizumab showed modest clinical activity in this study, the overall response rates observed did not support continued development in patients with solid tumors. SIGNIFICANCE: PD-1 blockade combined with targeted therapies have demonstrated encouraging preclinical activity. In this phase I study, patients with advanced solid tumors treated with pembrolizumab (PD-1 inhibitor) and either itacitinib (JAK1 inhibitor) or parsaclisib (PI3Kδ inhibitor) experienced limited clinical activity beyond that expected with checkpoint inhibition alone and showed little effect on T-cell infiltration in the tumor. These results do not support continued development of these combinations.


Subject(s)
Neoplasms , Programmed Cell Death 1 Receptor , Humans , Programmed Cell Death 1 Receptor/therapeutic use , Neoplasms/drug therapy , Diarrhea , Nausea
5.
ASAIO J ; 69(12): 1090-1098, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37774695

ABSTRACT

To address the unmet clinical need for pediatric circulatory support, we are developing an operationally versatile, hybrid, continuous-flow, total artificial heart ("Dragon Heart"). This device integrates a magnetically levitated axial and centrifugal blood pump. Here, we utilized a validated axial flow pump, and we focused on the development of the centrifugal pump. A motor was integrated to drive the centrifugal pump, achieving 50% size reduction. The motor design was simulated by finite element analysis, and pump design improvement was attained by computational fluid dynamics. A prototype centrifugal pump was constructed from biocompatible 3D printed parts for the housing and machined metal parts for the drive system. Centrifugal prototype testing was conducted using water and then bovine blood. The fully combined device ( i.e. , axial pump nested inside of the centrifugal pump) was tested to ensure proper operation. We demonstrated the hydraulic performance of the two pumps operating in tandem, and we found that the centrifugal blood pump performance was not adversely impacted by the simultaneous operation of the axial blood pump. The current iteration of this design achieved a range of operation overlapping our target range. Future design iterations will further reduce size and incorporate complete and active magnetic levitation.


Subject(s)
Heart Failure , Heart, Artificial , Heart-Assist Devices , Humans , Child , Animals , Cattle , Prosthesis Design , Hydrodynamics , Equipment Design
6.
Clin Cancer Res ; 29(16): 3026-3036, 2023 08 15.
Article in English | MEDLINE | ID: mdl-37378632

ABSTRACT

PURPOSE: Cancer vaccines represent a novel treatment modality with a complementary mode of action addressing a crucial bottleneck for checkpoint inhibitor (CPI) efficacy. CPIs are expected to release brakes in T-cell responses elicited by vaccination, leading to more robust immune responses. Increased antitumor T-cell responses may confer increased antitumor activity in patients with less immunogenic tumors, a subgroup expected to achieve reduced benefit from CPIs alone. In this trial, a telomerase-based vaccine was combined with pembrolizumab to assess the safety and clinical activity in patients with melanoma. PATIENTS AND METHODS: Thirty treatment-naïve patients with advanced melanoma were enrolled. Patients received intradermal injections of UV1 with adjuvant GM-CSF at two dose levels, and pembrolizumab according to the label. Blood samples were assessed for vaccine-induced T-cell responses, and tumor tissues were collected for translational analyses. The primary endpoint was safety, with secondary objectives including progression-free survival (PFS), overall survival (OS), and objective response rate (ORR). RESULTS: The combination was considered safe and well-tolerated. Grade 3 adverse events were observed in 20% of patients, with no grade 4 or 5 adverse events reported. Vaccination-related adverse events were mostly mild injection site reactions. The median PFS was 18.9 months, and the 1- and 2-year OS rates were 86.7% and 73.3%, respectively. The ORR was 56.7%, with 33.3% achieving complete responses. Vaccine-induced immune responses were observed in evaluable patients, and inflammatory changes were detected in posttreatment biopsies. CONCLUSIONS: Encouraging safety and preliminary efficacy were observed. Randomized phase II trials are currently ongoing.


Subject(s)
Melanoma , Telomerase , Humans , Antibodies, Monoclonal, Humanized , Melanoma/pathology , Vaccination
7.
Geroscience ; 45(5): 2785-2803, 2023 10.
Article in English | MEDLINE | ID: mdl-37261678

ABSTRACT

Cellular senescence increases with aging and results in secretion of pro-inflammatory factors that induce local and systemic tissue dysfunction. We conducted the first preclinical trial in a relevant middle-aged nonhuman primate (NHP) model to allow estimation of the main translatable effects of the senolytic combination dasatinib (D) and quercetin (Q), with and without caloric restriction (CR). A multi-systemic survey of age-related changes, including those on immune cells, adipose tissue, the microbiome, and biomarkers of systemic organ and metabolic health are reported. Age-, weight-, sex-, and glycemic control-matched NHPs (D + Q, n = 9; vehicle [VEH] n = 7) received two consecutive days of D + Q (5 mg/kg + 50 mg/kg) monthly for 6 months, where in month six, a 10% CR was implemented in both D + Q and VEH NHPs to induce equal weight reductions. D + Q reduced senescence marker gene expressions in adipose tissue and circulating PAI-1 and MMP-9. Improvements were observed in immune cell types with significant anti-inflammatory shifts and reductions in microbial translocation biomarkers, despite stable microbiomes. Blood urea nitrogen showed robust improvements with D + Q. CR resulted in significant positive body composition changes in both groups with further improvement in immune cell profiles and decreased GDF15 (p = 0.05), and the interaction of D + Q and CR dramatically reduced glycosylated hemoglobin A1c (p = 0.03). This work indicates that 6 months of intermittent D + Q exposure is safe and may combat inflammaging via immune benefits and improved intestinal barrier function. We also saw renal benefits, and with CR, improved metabolic health. These data are intended to provide direction for the design of larger controlled intervention trials in older patients.


Subject(s)
Quercetin , Senotherapeutics , Animals , Humans , Middle Aged , Aged , Dasatinib/pharmacology , Quercetin/pharmacology , Clinical Trials as Topic , Aging , Inflammation , Biomarkers , Primates
8.
NPJ Microgravity ; 9(1): 36, 2023 May 12.
Article in English | MEDLINE | ID: mdl-37173308

ABSTRACT

This study aims to determine whether astronauts who have not flown in space can provide an unbiased comparison to astronauts who have flown in space when analyzing long-term health outcomes such as incidence of chronic disease and mortality. Various propensity score methods failed to achieve good balance between groups, demonstrating that even with sophisticated rebalancing methods the group of non-flight astronauts cannot be demonstrated to be an unbiased comparison group for examining the effect of the hazards of spaceflight on incidence and mortality from chronic diseases.

9.
Dev Med Child Neurol ; 65(9): 1135-1136, 2023 09.
Article in English | MEDLINE | ID: mdl-37035937

Subject(s)
Bias , Humans , Time Factors
10.
Proc Biol Sci ; 290(1996): 20230520, 2023 04 12.
Article in English | MEDLINE | ID: mdl-37040808

ABSTRACT

Throughout evolution, organisms repeatedly developed elastic elements to power explosive body motions, overcoming ubiquitous limits on the power capacity of fast-contracting muscles. Seahorses evolved such a latch-mediated spring-actuated (LaMSA) mechanism; however, it is unclear how this mechanism powers the two complementary functions necessary for feeding: rapidly swinging the head towards the prey, and sucking water into the mouth to entrain it. Here, we combine flow visualization and hydrodynamic modelling to estimate the net power required for accelerating the suction feeding flows in 13 fish species. We show that the mass-specific power of suction feeding in seahorses is approximately three times higher than the maximum recorded from any vertebrate muscle, resulting in suction flows that are approximately eight times faster than similar-sized fishes. Using material testing, we reveal that the rapid contraction of the sternohyoideus tendons can release approximately 72% of the power needed to accelerate the water into the mouth. We conclude that the LaMSA system in seahorses is powered by two elastic elements, the sternohyoideus and epaxial tendons. These elements jointly actuate the coordinated acceleration of the head and the fluid in front of the mouth. These findings extend the known function, capacity and design of LaMSA systems.


Subject(s)
Smegmamorpha , Animals , Smegmamorpha/physiology , Feeding Behavior/physiology , Biomechanical Phenomena , Muscles/physiology , Fishes/physiology
11.
J Immunother Cancer ; 11(1)2023 01.
Article in English | MEDLINE | ID: mdl-36669791

ABSTRACT

BACKGROUND: Oncolytic virus V937 showed activity and safety with intratumoral administration. This phase 1 study evaluated intravenous V937±pembrolizumab in patients with advanced solid tumors. METHODS: Patients had advanced non-small cell lung cancer (NSCLC), urothelial cancer, metastatic castration-resistant prostate cancer, or melanoma in part A (V937 monotherapy), and metastatic NSCLC or urothelial cancer in part B (V937+pembrolizumab). Prior immunotherapy was permitted >28 days before study treatment. Patients received intravenous V937 on days 1, 3, and 5 (also on day 8 in part B) of the first 21-day cycle and on day 1 of subsequent cycles for eight cycles. Three ascending dose-escalation cohorts were studied. Dose-escalation proceeded if no dose-limiting toxicities (DLTs) occurred in cycle 1 of the previous cohort. In part B, patients also received pembrolizumab 200 mg every 3 weeks from day 8 for 2 years; dose-expansion occurred at the highest-dose cohort. Serial biopsies were performed. RESULTS: No DLTs occurred in parts A (n=18) or B (n=85). Grade 3-5 treatment-related adverse events (AEs) were not observed in part A and were experienced by 10 (12%) patients in part B. The most frequent treatment-related AEs (any grade) in part B were fatigue (36%), pruritus (18%), myalgia (14%), diarrhea (13%), pyrexia (13%), influenza-like illness (12%), and nausea (12%). At the highest tested dose, median intratumoral V937 concentrations were 117,631 copies/mL on day 8, cycle 1 in part A (n=6) and below the detection limit for most patients (86% (19/22)) on day 15, cycle 1 in part B. Objective response rates were 6% (part A), 9% in the NSCLC dose-expansion cohort (n=43), and 20% in the urothelial cancer dose-expansion cohort (n=35). CONCLUSIONS: Intravenous V937+pembrolizumab had a manageable safety profile. Although V937 was detected in tumor tissue, in NSCLC and urothelial cancer, efficacy was not greater than that observed in previous studies with pembrolizumab monotherapy. TRIAL REGISTRATION NUMBER: NCT02043665.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Oncolytic Viruses , Male , Humans , Carcinoma, Non-Small-Cell Lung/drug therapy , Lung Neoplasms/drug therapy , Antibodies, Monoclonal, Humanized/adverse effects
12.
Cancer Immunol Immunother ; 72(6): 1405-1415, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36445410

ABSTRACT

BACKGROUND: CAPRA (NCT02565992) evaluated Coxsackievirus A21 (V937) + pembrolizumab for metastatic/unresectable stage IIIB-IV melanoma. METHODS: Patients received intratumoral V937 on days 1, 3, 5, and 8 (then every 3 weeks [Q3W]) and intravenous pembrolizumab 2 mg/kg Q3W from day 8. Primary endpoint was safety. RESULTS: Median time from first dose to data cutoff was 32.0 months. No dose-limiting toxicities occurred; 14% (5/36) of patients experienced grade 3‒5 treatment-related adverse events. Objective response rate was 47% (complete response, 22%). Among 17 responders, 14 (82%) had responses ≥ 6 months. Among 8 patients previously treated with immunotherapy, 3 responded (1 complete, 2 partial). Responses were associated with increased serum CXCL10 and CCL22, suggesting viral replication contributes to antitumor immunity. For responders versus nonresponders, there was no difference in baseline tumor PD-L1 expression, ICAM1 expression, or CD3+ infiltrates. Surprisingly, the baseline cell density of CD3+CD8- T cells in the tumor microenvironment was significantly lower in responders compared with nonresponders (P = 0.0179). CONCLUSIONS: These findings suggest responses to this combination may be seen even in patients without a typical "immune-active" microenvironment. TRIAL REGISTRATION NUMBER: NCT02565992.


Subject(s)
Melanoma , Oncolytic Viruses , Humans , Animals , Goats , Antibodies, Monoclonal, Humanized/adverse effects , Melanoma/drug therapy , Tumor Microenvironment
13.
Artif Organs ; 47(4): 680-694, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36524792

ABSTRACT

BACKGROUND: The purpose of this research is to address ongoing device shortfalls for pediatric patients by developing a novel pediatric hybrid total artificial heart (TAH). The valveless magnetically-levitated MCS device (Dragon Heart) has only two moving parts, integrates an axial and centrifugal blood pump into a single device, and will occupy a compact footprint within the chest for the pediatric patient population. METHODS: Prior work on the Dragon Heart focused on the development of pump designs to achieve hemodynamic requirements. The impeller of these pumps was shaft-driven and thus could not be integrated for testing. The presented research leverages an existing magnetically levitated axial flow pump and focuses on centrifugal pump development. Using the axial pump diameter as a geometric constraint, a shaftless, magnetically supported centrifugal pump was designed for placement circumferentially around the axial pump domain. The new design process included the computational analysis of more than 50 potential centrifugal impeller geometries. The resulting centrifugal pump designs were prototyped and tested for levitation and no-load rotation, followed by in vitro testing using a blood analog. To meet physiologic demands, target performance goals were pressure rises exceeding 90 mm Hg for flow rates of 1-5 L/min with operating speeds of less than 5000 RPM. RESULTS: Three puck-shaped, channel impellers for the centrifugal blood pump were selected based on achieving performance and space requirements for magnetic integration. A quasi-steady flow analysis revealed that the impeller rotational position led to a pulsatile component in the pressure generation. After prototyping, the centrifugal prototypes (3, 4, and 5 channeled designs) demonstrated levitation and no-load rotation. Hydraulic experiments established pressure generation capabilities beyond target requirements. The pressure-flow performance of the prototypes followed expected trends with a dependence on rotational speed. Pulsatile blood flow was observed without pump-speed modulation due to rotating channel passage frequency. CONCLUSION: The results are promising in the advancement of this pediatric TAH. The channeled impeller design creates pressure-flow curves that are decoupled from the flow rate, a benefit that could reduce the required controller inputs and improve treatment of hypertensive patients.


Subject(s)
Heart, Artificial , Heart-Assist Devices , Child , Humans , Magnets , Prosthesis Design , Pulsatile Flow , Magnetics , Equipment Design
14.
Sensors (Basel) ; 22(21)2022 Nov 04.
Article in English | MEDLINE | ID: mdl-36366209

ABSTRACT

Dry electrodes offer an accessible continuous acquisition of biopotential signals as part of current in-home monitoring systems but often face challenges of high-contact impedance that results in poor signal quality. The performance of dry electrodes could be affected by electrode material and skin hydration. Herein, we investigate these dependencies using a circuit skin-electrode interface model, varying material and hydration in controlled benchtop experiments on a biomimetic skin phantom simulating dry and hydrated skin. Results of the model demonstrate the contribution of the individual components in the circuit to total impedance and assist in understanding the role of electrode material in the mechanistic principle of dry electrodes. Validation was performed by conducting in vivo skin-electrode contact impedance measurements across ten normative human subjects. Further, the impact of the electrode on biopotential signal quality was evaluated by demonstrating an ability to capture clinically relevant electrocardiogram signals by using dry electrodes integrated into a toilet seat cardiovascular monitoring system. Titanium electrodes resulted in better signal quality than stainless steel electrodes. Results suggest that relative permittivity of native oxide of electrode material come into contact with the skin contributes to the interface impedance, and can lead to enhancement in the capacitive coupling of biopotential signals, especially in dry skin individuals.


Subject(s)
Electrocardiography , Skin , Humans , Electric Impedance , Electrodes , Monitoring, Physiologic/methods
15.
J Vis Exp ; (187)2022 09 07.
Article in English | MEDLINE | ID: mdl-36156068

ABSTRACT

Aligned collagen I (COL1) fibers guide tumor cell motility, influence endothelial cell morphology, control stem cell differentiation, and are a hallmark of cardiac and musculoskeletal tissues. To study cell response to aligned microenvironments in vitro, several protocols have been developed to generate COL1 matrices with defined fiber alignment, including magnetic, mechanical, cell-based, and microfluidic methods. Of these, microfluidic approaches offer advanced capabilities such as accurate control over fluid flows and the cellular microenvironment. However, the microfluidic approaches to generate aligned COL1 matrices for advanced in vitro culture platforms have been limited to thin "mats" (<40 µm in thickness) of COL1 fibers that extend over distances less than 500 µm and are not conducive to 3D cell culture applications. Here, we present a protocol to fabricate 3D COL1 matrices (130-250 µm in thickness) with millimeter-scale regions of defined fiber alignment in a microfluidic device. This platform provides advanced cell culture capabilities to model structured tissue microenvironments by providing direct access to the micro-engineered matrix for cell culture.


Subject(s)
Collagen , Hydrogels , Cell Culture Techniques/methods , Cellular Microenvironment , Collagen Type I
16.
Front Cardiovasc Med ; 9: 886874, 2022.
Article in English | MEDLINE | ID: mdl-35990958

ABSTRACT

Clinically-available blood pumps and total artificial hearts for pediatric patients continue to lag well behind those developed for adults. We are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). The hybrid TAH design integrates both an axial and centrifugal blood pump within a single, compact housing. The centrifugal pump rotates around the separate axial pump domain, and both impellers rotate around a common central axis. Here, we concentrate our development effort on the centrifugal blood pump by performing computational fluid dynamics (CFD) analysis of the blood flow through the pump. We also conducted transient CFD analyses (quasi-steady and transient rotational sliding interfaces) to assess the pump's dynamic performance conditions. Through modeling, we estimated the pressure generation, scalar stress levels, and fluid forces exerted on the magnetically levitated impellers. To further the development of the centrifugal pump, we also built magnetically-supported prototypes and tested these in an in vitro hydraulic flow loop and via 4-h blood bag hemolytic studies (n = 6) using bovine blood. The magnetically levitated centrifugal prototype delivered 0-6.75 L/min at 0-182 mmHg for 2,750-4,250 RPM. Computations predicted lower pressure-flow performance results than measured by testing; axial and radial fluid forces were found to be <3 N, and mechanical power usage was predicted to be <5 Watts. Blood damage indices (power law weighted exposure time and scalar stress) were <2%. All data trends followed expectations for the centrifugal pump design. Six peaks in the pressure rise were observed in the quasi-steady and transient simulations, correlating to the blade passage frequency of the 6-bladed impeller. The average N.I.H value (n = 6) was determined to be 0.09 ± 0.02 g/100 L, which is higher than desired and must be addressed through design improvement. These data serve as a strong foundation to build upon in the next development phase, whereby we will integrate the axial flow pump component.

17.
Adv Healthc Mater ; 11(21): e2200802, 2022 11.
Article in English | MEDLINE | ID: mdl-35953453

ABSTRACT

Microfluidic tissue barrier models have emerged to address the lack of physiological fluid flow in conventional "open-well" Transwell-like devices. However, microfluidic techniques have not achieved widespread usage in bioscience laboratories because they are not fully compatible with traditional experimental protocols. To advance barrier tissue research, there is a need for a platform that combines the key advantages of both conventional open-well and microfluidic systems. Here, a plug-and-play flow module is developed to introduce on-demand microfluidic flow capabilities to an open-well device that features a nanoporous membrane and live-cell imaging capabilities. The magnetic latching assembly of this design enables bi-directional reconfiguration and allows users to conduct an experiment in an open-well format with established protocols and then add or remove microfluidic capabilities as desired. This work also provides an experimentally-validated flow model to select flow conditions based on the experimental needs. As a proof-of-concept, flow-induced alignment of endothelial cells and the expression of shear-sensitive gene targets are demonstrated, and the different phases of neutrophil transmigration across a chemically stimulated endothelial monolayer under flow conditions are visualized. With these experimental capabilities, it is anticipated that both engineering and bioscience laboratories will adopt this reconfigurable design due to the compatibility with standard open-well protocols.


Subject(s)
Microfluidic Analytical Techniques , Microfluidics , Endothelial Cells , Microfluidic Analytical Techniques/methods
18.
Biofabrication ; 14(3)2022 06 23.
Article in English | MEDLINE | ID: mdl-35735228

ABSTRACT

Randomly oriented type I collagen (COL1) fibers in the extracellular matrix are reorganized by biophysical forces into aligned domains extending several millimeters and with varying degrees of fiber alignment. These aligned fibers can transmit traction forces, guide tumor cell migration, facilitate angiogenesis, and influence tissue morphogenesis. To create aligned COL1 domains in microfluidic cell culture models, shear flows have been used to align thin COL1 matrices (<50µm in height) in a microchannel. However, there has been limited investigation into the role of shear flows in aligning 3D hydrogels (>130µm). Here, we show that pure shear flows do not induce fiber alignment in 3D atelo COL1 hydrogels, but the simple addition of local extensional flow promotes alignment that is maintained across several millimeters, with a degree of alignment directly related to the extensional strain rate. We further advance experimental capabilities by addressing the practical challenge of accessing a 3D hydrogel formed within a microchannel by introducing a magnetically coupled modular platform that can be released to expose the microengineered hydrogel. We demonstrate the platform's capability to pattern cells and fabricate multi-layered COL1 matrices using layer-by-layer fabrication and specialized modules. Our approach provides an easy-to-use fabrication method to achieve advanced hydrogel microengineering capabilities that combine fiber alignment with biofabrication capabilities.


Subject(s)
Collagen , Hydrogels , Cell Culture Techniques , Extracellular Matrix , Hydrogels/pharmacology
19.
Sens Actuators A Phys ; 3402022 Jun 16.
Article in English | MEDLINE | ID: mdl-35493959

ABSTRACT

Advances in the integration of wearable devices in our daily life have led to the development of new electrode designs for biopotential monitoring. Historically, the development and testing of wearable electrodes for the acquisition of biopotential signals has been empirical, relying on experiments on human volunteers. However, the lack of explicit control on human variables, the intra-, and inter-subject variability complicates the understanding of the performance of these wearable electrodes. Herein, phantom mimicking the electrical properties of the skin in the low-frequency range (1 Hz-1000 Hz), which has the potential to be used as a platform for controlled benchtop experiments for testing electrode functionality, is demonstrated. The fabricated phantom comprises two layers representing the deeper tissues and stratum corneum. The lower layer of the phantom mimicking deeper tissues was realized using polyvinyl alcohol cryogel (PVA-c) prepared with 0.9% W/W saline solution by a freeze-thaw technique. The properties of the upper layer representing the stratum corneum were simulated using a 100µm thick layer fabricated by spin-coating a mixture of polydimethylsiloxane (PDMS), 2.5% W/W carbon black (CB) for conductance, and 40% W/W barium titanate (BaTiO3) as a dielectric. The hydration of the stratum corneum was modeled in a controlled way by varying porosity of the phantom's upper layer. Impedance spectroscopy measurements were carried out to investigate the electrical performance of the fabricated phantom and validated against the impedance response obtained across a physiological skin impedance range of five human subjects. The results indicated that the Bode plot depicting the impedance response obtained on the phantom was found to lie in the human skin range. Moreover, it was observed that the change of porosity provides control over the hydration and the phantom can be tuned as per the skin ranges among different individuals. Also, the phantom was able to mimic the impact of dry and hydrated skin on a simulated ECG signal in the time domain. The developed skin phantom is affordable, fairly easy to manufacture, stable over time, and can be used as a platform for benchtop testing of new electrode designs.