Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Polymers (Basel) ; 15(12)2023 Jun 19.
Article in English | MEDLINE | ID: mdl-37376383

ABSTRACT

Currently, the preparation of actuators based on ionic electroactive polymers with a fast response is considered an urgent topic. In this article, a new approach to activate polyvinyl alcohol (PVA) hydrogels by applying an AC voltage is proposed. The suggested approach involves an activation mechanism in which the PVA hydrogel-based actuators undergo extension/contraction (swelling/shrinking) cycles due to the local vibration of the ions. The vibration does not cause movement towards the electrodes but results in hydrogel heating, transforming the water molecules into a gaseous state and causing the actuator to swell. Two types of linear actuators based on PVA hydrogels were prepared, using two types of reinforcement for the elastomeric shell (spiral weave and fabric woven braided mesh). The extension/contraction of the actuators, activation time, and efficiency were studied, considering the PVA content, applied voltage, frequency, and load. It was found that the overall extension of the spiral weave-reinforced actuators under a load of ~20 kPa can reach more than 60%, with an activation time of ~3 s by applying an AC voltage of 200 V and a frequency of 500 Hz. Conversely, the overall contraction of the actuators reinforced by fabric woven braided mesh under the same conditions can reach more than 20%, with an activation time of ~3 s. Moreover, the activation force (swelling load) of the PVA hydrogels can reach up to 297 kPa. The developed actuators have broad applications in medicine, soft robotics, the aerospace industry, and artificial muscles.

2.
Polymers (Basel) ; 15(12)2023 Jun 20.
Article in English | MEDLINE | ID: mdl-37376401

ABSTRACT

Elastomeric materials have great application potential in actuator design and soft robot development. The most common elastomers used for these purposes are polyurethanes, silicones, and acrylic elastomers due to their outstanding physical, mechanical, and electrical properties. Currently, these types of polymers are produced by traditional synthetic methods, which may be harmful to the environment and hazardous to human health. The development of new synthetic routes using green chemistry principles is an important step to reduce the ecological footprint and create more sustainable biocompatible materials. Another promising trend is the synthesis of other types of elastomers from renewable bioresources, such as terpenes, lignin, chitin, various bio-oils, etc. The aim of this review is to address existing approaches to the synthesis of elastomers using "green" chemistry methods, compare the properties of sustainable elastomers with the properties of materials produced by traditional methods, and analyze the feasibility of said sustainable elastomers for the development of actuators. Finally, the advantages and challenges of existing "green" methods of elastomer synthesis will be summarized, along with an estimation of future development prospects.

3.
Polymers (Basel) ; 15(3)2023 Feb 02.
Article in English | MEDLINE | ID: mdl-36772060

ABSTRACT

Preparing high-strength polymeric materials using an orientation drawing process is considered one of the most urgent topics in the modern world. Graphene nanoplates/polyaniline (GNP/PANI) were added to the commercial grade UHMWPE (GUR 4120) matrix as a filler with antifriction properties. The effect of GNP/PANI addition on the structure, the orientation process, the void formation (cavitation), the mechanical, and tribological properties was studied using differential scanning calorimetry (DSC), dynamical mechanical analysis (DMA), and scanning electron microscopy (SEM). The paper's findings indicated an increase in the cavitation effect of 120-320% after the addition of GNP/PANI to the UHMWPE polymer matrix. This increase, during the process of the oriented films' thermal orientation hardening, led, in turn, to a decrease in the tensile strength during the process of the oriented films' thermal orientation hardening. Furthermore, the decrease in the coefficient of friction in the best samples of oriented UHMWPE films was two times greater, and the increase in wear resistance was more than an order of magnitude. This process was part of the orientation hardening process for the UHMWPE films containing PE-wax as an intermolecular lubricant, as well as the presence of GNP/PANI in the material, which have a high resistance to abrasive wear.

4.
Polymers (Basel) ; 14(17)2022 Aug 26.
Article in English | MEDLINE | ID: mdl-36080587

ABSTRACT

Polymer smart materials are a broad class of polymeric materials that can change their shapes, mechanical responses, light transmissions, controlled releases, and other functional properties under external stimuli. A good understanding of the aspects controlling various types of shape memory phenomena in shape memory polymers (SMPs), such as polymer structure, stimulus effect and many others, is not only important for the preparation of new SMPs with improved performance, but is also useful for the optimization of the current ones to expand their application field. In the present era, simple understanding of the activation mechanisms, the polymer structure, the effect of the modification of the polymer structure on the activation process using fillers or solvents to develop new reliable SMPs with improved properties, long lifetime, fast response, and the ability to apply them under hard conditions in any environment, is considered to be an important topic. Moreover, good understanding of the activation mechanism of the two-way shape memory effect in SMPs for semi-crystalline polymers and liquid crystalline elastomers is the main key required for future investigations. In this article, the principles of the three basic types of external stimuli (heat, chemicals, light) and their key parameters that affect the efficiency of the SMPs are reviewed in addition to several prospective applications.

5.
Nanomaterials (Basel) ; 12(13)2022 Jul 01.
Article in English | MEDLINE | ID: mdl-35808110

ABSTRACT

Unlike traditional actuators, such as piezoelectric ceramic or metallic actuators, polymer actuators are currently attracting more interest in biomedicine due to their unique properties, such as light weight, easy processing, biodegradability, fast response, large active strains, and good mechanical properties. They can be actuated under external stimuli, such as chemical (pH changes), electric, humidity, light, temperature, and magnetic field. Electroactive polymers (EAPs), called 'artificial muscles', can be activated by an electric stimulus, and fixed into a temporary shape. Restoring their permanent shape after the release of an electrical field, electroactive polymer is considered the most attractive actuator type because of its high suitability for prosthetics and soft robotics applications. However, robust control, modeling non-linear behavior, and scalable fabrication are considered the most critical challenges for applying the soft robotic systems in real conditions. Researchers from around the world investigate the scientific and engineering foundations of polymer actuators, especially the principles of their work, for the purpose of a better control of their capability and durability. The activation method of actuators and the realization of required mechanical properties are the main restrictions on using actuators in real applications. The latest highlights, operating principles, perspectives, and challenges of electroactive materials (EAPs) such as dielectric EAPs, ferroelectric polymers, electrostrictive graft elastomers, liquid crystal elastomers, ionic gels, and ionic polymer-metal composites are reviewed in this article.

6.
Polymers (Basel) ; 12(11)2020 Oct 30.
Article in English | MEDLINE | ID: mdl-33143255

ABSTRACT

Three types of glue based on thiol-ene reaction, polyvinyl alcohol (PVA)/cellulose, and phenol formaldehyde were prepared and applied on modified ultra-high molecular weight polyethylene (UHMWPE) samples grafted by cellulose. In comparison with unmodified UHMWPE samples, T-peel tests on the modified and grafted UHMWPE films showed an increase in the peel strength values for the glues based on thiol-ene reaction, PVA/cellulose, and phenol formaldehyde by 40, 29, and 41 times, respectively. The maximum peel strength value of 0.62 Kg/cm was obtained for the glue based on phenol formaldehyde. Mechanical tests for the cylindrical multi-UHMWPE forms samples, made of porous UHMWPE as a trabecular layer and an armored layer (cortical layer) that consists of bulk and UHMWPE films, indicated an improvement in the mechanical properties of these samples for all glue types, as a result of the UHMWPE films existence and the increase in the number of their layers. The maximum compressive yield strength and compressive modulus values for the armored layer (bulk and six layers of the UHMWPE films using the glue based on thiol-ene reaction) were 44.1 MPa (an increase of 17%) and 1130 MPa (an increase of 36%), respectively, in comparison with one armored layer of bulk UHMWPE. A hemocompatibility test carried out on these glues clarified that the modified UHMWPE grafted by cellulose with glues based on PVA/cellulose and thiol-ene reaction were classified as biocompatible materials. These multi-UHMWPE forms composites can be considered a promising development for joint reconstruction.

7.
Materials (Basel) ; 13(15)2020 Aug 03.
Article in English | MEDLINE | ID: mdl-32756415

ABSTRACT

Since obtaining a highly oriented structure based on a large-scale commercial ultra-high molecular weight polyethylene (UHMWPE) is considered very difficult due to its high molecular weight and melting index, modifying the structure of these cheap commercial UHMWPE brands into a supra-molecular structure with fiber-forming properties by adding a small amount of polyethylene wax (PE-wax) will provide the possibility to obtain highly oriented UHMWPE products with enhanced mechanical and tribological properties. In this work, highly oriented UHMWPE/PE-wax films were prepared. The PE-wax affected the UHMWPE as an intermolecular lubricant. The obtained lamellar structure of the UHMWPE/PE-wax composites had a better processability. The UHMWPE and UHMWPE/PE-wax structures for the xerogels and the films were studied by using differential scanning calorimetry and scanning electron microscopy. The PE-wax presence enhanced the mechanical properties of the UHMWPE/PE-wax films to a high degree. The highest average value of the tensile strength was 1320 MPa (an increase of 78%) obtained by adding a PE-wax content of 1.0 wt.%, and the highest average value of the Young's modulus was 56.8 GPa (an increase of 71%) obtained by adding a PE-wax content of 2.0 wt.%. The addition of the PE-wax increased the work of fracture values of the UHMWPE/PE-wax films up to 233%. The formation of the cavities was observed in the virgin UHMWPE films more than in the UHMWPE/PE-wax films, and the whitening of the oriented films was related to the crystallization process more than to the cavitation phenomenon. The coefficient of friction of the oriented UHMWPE/PE-wax films improved by 33% in comparison with the isotropic UHMWPE, and by 7% in comparison with the oriented virgin UHMWPE films.

8.
Materials (Basel) ; 13(13)2020 Jul 06.
Article in English | MEDLINE | ID: mdl-32640623

ABSTRACT

A hybrid implant with a structure mimicking that of natural bone was developed. Titanium alloy Ti-6Al-4V prepared with three-dimensional (3D)-printing technology was used to simulate the cortical-bone layer. The mismatch in the mechanical properties of bone and titanium alloy was solved by creating special perforations in the titanium's surface. Porous ultra-high molecular weight polyethylene (UHMWPE) with high osteogenous properties was used to simulate the cancellous-bone tissue. A method for creating a porous UHMWPE structure inside the titanium reinforcement is proposed. The porous UHMWPE was studied with scanning electron microscope (SEM) to confirm that the pores that formed were open, interconnected, and between 50 and 850 µm in size. Mechanical-compression tests done on the obtained UHMWPE/titanium-hybrid-implant samples showed that their mechanical properties simulated those of natural bone.

9.
Polymers (Basel) ; 11(1)2018 Dec 24.
Article in English | MEDLINE | ID: mdl-30960007

ABSTRACT

Highly oriented UHMWPE films were reinforced with functionalized graphene nanoplates (GNP). GNP was functionalized by deposition of polyaniline (PANI) on the GNP surface. The structure of GNP/PANI was studied by Raman spectroscopy, and the structure of xerogels and films based on UHMWPE was studied by DSC and SEM. PANI promotes the reduction of the GNP aggregation in the UHMWPE matrix and increases the degree of crystallinity due to heterogeneous crystallization. The new lamellar crystal structure has a high drawability. The highest value of the tensile strength 1330 MPa (an increase of 45%) was obtained with a filler content of 2 wt % GNP/PANI, and the highest value of Young's modulus 41 GPa (an increase of 32%) was obtained with a filler content of 1 wt % GNP/PANI. The effect of GNP with PANI fillers on the dynamic mechanical properties of the UHMWPE films was discussed.

SELECTION OF CITATIONS
SEARCH DETAIL
...