Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Eur J Vasc Endovasc Surg ; 58(6): 831-838, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31615695

ABSTRACT

OBJECTIVES: At 12 months follow up of the PLIANT study, clinical success and efficacy of the E-liac Stent Graft System (JOTEC GmbH, Hechingen, Germany) were evaluated. Clinical success was defined as aneurysm exclusion (no type I, III, IV endoleak) with primary patency of the internal iliac artery (IIA) and external iliac artery (EIA) on the E-liac implantation side. METHODS: In this prospective multicentre European observational study, clinical and morphological data of 45 patients (93% male, mean age 72 y) were prospectively collected in 11 European centres between July 2014 and June 2016. Forty patients underwent an aorto-iliac (three patients bilaterally) treatment and five an isolated iliac treatment. RESULTS: At 12 months follow up, data were available for 42 patients. Overall clinical success at 12 months was 90%, with a survival rate of 100%. Four patients (10%) did not achieve clinical success, one with an internal iliac artery (IIA) occlusion on the E-liac implantation side, one with an infrarenal type Ia endoleak, and two with type Ib endoleaks in IIA. At 12 months the primary patency rate in the internal iliac artery on the iliac side branch implantation side was 98%. Two patients (5%) received E-liac related re-interventions: one caused by an edge stenosis at the distal end of the graft limb in the external iliac artery (EIA) and one caused by thrombo-embolism in the external iliac artery. Thus, for the EIA, primary and secondary patency rates were 98% and 100%, respectively. CONCLUSIONS: The low device related re-intervention rate of 5%, the high survival rate of 100%, and the high primary patency rates of 98% for the IIA and EIA at 12 month follow up demonstrate the safety and efficacy of the E-liac Stent Graft System. Long term 36 month results are awaited to confirm the efficacy and durability.


Subject(s)
Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis/adverse effects , Endoleak/epidemiology , Endovascular Procedures/instrumentation , Graft Occlusion, Vascular/epidemiology , Iliac Aneurysm/surgery , Self Expandable Metallic Stents/adverse effects , Aged , Aged, 80 and over , Blood Vessel Prosthesis Implantation/adverse effects , Computed Tomography Angiography , Endoleak/diagnostic imaging , Endoleak/etiology , Endovascular Procedures/adverse effects , Europe , Female , Follow-Up Studies , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Humans , Iliac Artery/diagnostic imaging , Iliac Artery/surgery , Male , Middle Aged , Prospective Studies , Reoperation/statistics & numerical data , Treatment Outcome
2.
Vascular ; 26(6): 647-656, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30037302

ABSTRACT

OBJECTIVES: To study the safety and feasibility of the E-liac Stent Graft System® in patients with aorto/iliac aneurysms. METHODS: A prospective multicentric European registry of patients receiving the E-liac Stent Graft System® was conducted. Endpoints of the study included the technical success as well as periprocedural events and 30-day endoleaks, reinterventions, internal and external iliac artery patency and mortality. RESULTS: Between July 2014 and June 2016, a total of 45 patients (93% men, mean age 72 years, range 53-90 years) were enrolled at 11 sites in four European countries. Five patients received an isolated iliac treatment. Thirty-seven patients were treated with a combination of an abdominal stent graft and a unilateral E-liac and three in combination with bilateral E-liac. All E-liac Stent Grafts (48) were implanted in the intended position and the internal iliac arteries were successfully bridged. Two patients did not receive clinical success, due to endoleak type Ia of the aortic stent graft. At 30-day follow-up, clinical success rate was 96%. Three successful endovascular reinterventions were performed within the 30-day follow-up: one due to a type Ia endoleak in the common iliac artery, one due to type Ia endoleak of the aortic stent graft, and one due to bilateral lower limb claudication provoked by stent graft limb stenosis. At 30-day, a 100% survival rate and complete absence of pelvic or buttock ischemia/claudication were reported. Primary patency at 30 days was 100% for the internal iliac artery and 98% for the external iliac artery with an assisted patency of 100% in the latter. CONCLUSIONS: The high clinical success rate, low rates of device-related reinterventions (2%), and excellent patency rate demonstrate the safety and feasibility of the E-liac Stent Graft System. Long-term results are awaited to state efficacy and durability. Clinical Trials.gov. Identifier no. NCT02209194.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Iliac Aneurysm/surgery , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Feasibility Studies , Female , Humans , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/physiopathology , Male , Middle Aged , Postoperative Complications/etiology , Prospective Studies , Prosthesis Design , Time Factors , Treatment Outcome , Vascular Patency
3.
Ann Vasc Surg ; 28(4): 1034.e5-8, 2014 May.
Article in English | MEDLINE | ID: mdl-24211411

ABSTRACT

We report a rare case of isolated spontaneous renal artery dissection treated by stent placement. A 59-year-old man presented with a sudden onset of left flank pain and severe hypertension together with elevated creatinine levels. A computed tomography scan revealed a focal dissection at the left renal artery (LRA) with an infarcted left kidney. Despite medical treatment with 4 drugs, the patient's blood pressure remained uncontrolled. Angiography confirmed the diagnosis. A 6- × 60-mm Xpert stent (Abbott Vascular, Temecula, CA) was deployed at the LRA, achieving an enlarged true lumen with a patent stent. After the procedure, acute renal impairment was observed but pain subsided and blood pressure normalized under the treatment prescribed. At 12 months of follow-up, the patient was normotensive and asymptomatic with mild chronic renal failure and a patent LRA stent on doppler ultrasonography. The endovascular treatment of isolated spontaneous renal artery dissection appears to be feasible and effective and could be the first-line treatment when revascularization is needed.


Subject(s)
Aortic Dissection/therapy , Endovascular Procedures/instrumentation , Renal Artery , Stents , Aortic Dissection/diagnosis , Aortic Dissection/physiopathology , Antihypertensive Agents/therapeutic use , Blood Pressure , Humans , Hypertension, Renovascular/diagnosis , Hypertension, Renovascular/drug therapy , Hypertension, Renovascular/physiopathology , Infarction/diagnosis , Infarction/therapy , Kidney Failure, Chronic/diagnosis , Kidney Failure, Chronic/physiopathology , Kidney Failure, Chronic/therapy , Male , Middle Aged , Renal Artery/diagnostic imaging , Renal Artery/physiopathology , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...