1.
World J Urol ; 42(1): 310, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722553

ABSTRACT

INTRODUCTION: Ionizing radiation is used daily during endourological procedures. Despite the dangers of both deterministic and stochastic effects of radiation, there is a lack of knowledge and awareness among urologists. This study reviewed the literature to identify the radiation exposure (RE) of urologists during endourological procedures. METHODS: A literature search of the Medline, Web of Science, and Google Scholar databases was conducted to collect articles related to the radiation dose to urologists during endourological procedures. A total of 1966 articles were screened. 21 publications met the inclusion criteria using the PRIMA standards. RESULTS: Twenty-one studies were included, of which 14 were prospective. There was a large variation in the mean RE to the urologist between studies. PCNL had the highest RE to the urologist, especially in the prone position. RE to the eyes and hands was highest in prone PCNL, compared to supine PCNL. Wearing a thyroid shield and lead apron resulted in a reduction of RE ranging between 94.1 and 100%. Educational courses about the possible dangers of radiation decreased RE and increased awareness among endourologists. CONCLUSIONS: This is the first systematic review in the literature analyzing RE to urologists over a time period of more than four decades. Wearing protective garments such as lead glasses, a thyroid shield, and a lead apron are essential to protect the urologist from radiation. Educational courses on radiation should be encouraged to further reduce RE and increase awareness on the harmful effects of radiation, as the awareness of endourologists is currently very low.


Subject(s)
Occupational Exposure , Radiation Exposure , Urologists , Humans , Urology , Urologic Surgical Procedures
2.
World J Urol ; 42(1): 298, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38709327

ABSTRACT

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Subject(s)
Equipment Design , Kidney , Lighting , Ureteroscopes , Models, Anatomic , Humans
3.
World J Urol ; 42(1): 294, 2024 May 05.
Article in English | MEDLINE | ID: mdl-38704777

ABSTRACT

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Subject(s)
Ureteroscopes , Ureteroscopy , Humans , Equipment Design , Lighting , Pliability , Kidney Calices
4.
Turk J Med Sci ; 54(1): 185-193, 2024.
Article in English | MEDLINE | ID: mdl-38812627

ABSTRACT

Background/aim: Management of asymptomatic kidney stones is an ongoing debate with follow-up and treatment guidelines based on low-level evidence. Our aim was to evaluate current management of asymptomatic urinary stones. Materials and methods: A 70-question survey was designed in collaboration with European Association of Urology, Young Academic Urologists, Section of Uro-Technology and Section of Urolithiasis groups and distributed. Responders filled out hypothetical scenarios from 2 perspectives, either as treating physicians, or as patients themselves. Results: A total of 212 (40.01%) responses were obtained. Median responder age was 39 years. 75% of responders were interested in "urolithiasis". 82.5% had never experienced a renal colic, 89.6% had never undergone urolithiasis treatment.Overall, as the kidney stone scenarios got more complicated, the invasiveness of the treatment preference increased. As "the physician", responders preferred the conservative option in all situations more than they would choose as "the patient". For ureteral stones, conservative approach was most preferred for small stones and ureteroscopy became more preferred as the stone size increased.For smaller kidney stones, the most preferred follow-up schedule was 4-6 monthly, whereas for larger and complicated stones it was 0-3 monthly from both perspectives respectively. For all ureteral stone scenarios, 0-4 weekly follow-up was mostly preferred.Interestingly, having had a renal colic was an independent predictor of an interventional approach, whereas having had an intervention was an independent predictor of a conservative approach. Conclusion: Current treatment and follow-up patterns of asymptomatic urinary stones are in agreement with international guidelines on symptomatic stones.In most of the urolithiasis situations urologists chose a conservative approach for their patients compared to what they would prefer for themselves. Conversely, urologists, in the scenarios as "the patient", would like to have a more frequent follow-up schedule for their stones compared to how they would follow-up their patients.


Subject(s)
Urologists , Humans , Adult , Surveys and Questionnaires , Male , Female , Urology , Kidney Calculi/therapy , Ureteroscopy , Practice Patterns, Physicians'/statistics & numerical data , Urolithiasis/therapy , Middle Aged , Europe , Attitude of Health Personnel , Asymptomatic Diseases/therapy
5.
World J Urol ; 42(1): 277, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38691160

ABSTRACT

PURPOSE: To prospectively evaluate the rate and associated risk factors of early infectious complications after ureterorenoscopy for urolithiasis. METHODS: After ethical committee approval, 400 therapeutic retrograde ureterorenoscopy procedures between August 3, 2020 and November 24, 2021 were included for analysis in a single-center study. Postoperative infection was defined as an afebrile urinary tract infection, fever (≥ 38 °C) with pyuria (≥ 300 WBC/µL) or proven urinary pathogen, and urosepsis. The primary outcome was the rate of infectious complications after ureterorenoscopy. Secondary outcomes were the perioperative factors that increased the risk of infectious complications within 30 days of surgery using univariate and multivariate logistic regression analysis. RESULTS: Twenty-nine of four hundred (7.3%) patients developed an infectious complication within 30 days after ureterorenoscopy. Ten (2.5%) patients developed an afebrile urinary tract infection, eight (2.0%) developed fever with pyuria, five (1.3%) febrile urinary tract infection, and six (1.5%) urosepsis. On univariate analysis, preoperative stent-type JFil® pigtail suture stent was significantly associated with the dependent variable (p < 0.001). On multivariate logistic regression analysis, older age (OR 1.035; 95% CI 1.006-1.070; p = 0.02) was found to be significantly associated with developing a postoperative infectious complication. CONCLUSIONS: A 7.3% rate of postoperative infectious complications and 1.5% urosepsis rate were observed after therapeutic ureterorenoscopy, without the need of intensive care admission. The only significant risk factors were preoperative stent type (JFil® pigtail suture stent) on univariate analysis, and older age on multivariate logistic regression analysis. Further multicentric prospective observational data are needed in this field.


Subject(s)
Postoperative Complications , Ureteroscopy , Urinary Tract Infections , Humans , Male , Female , Prospective Studies , Risk Factors , Ureteroscopy/adverse effects , Middle Aged , Urinary Tract Infections/epidemiology , Urinary Tract Infections/etiology , Adult , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Aged , Time Factors , Sepsis/etiology , Sepsis/epidemiology , Urolithiasis/surgery
6.
World J Urol ; 42(1): 355, 2024 May 26.
Article in English | MEDLINE | ID: mdl-38796790

ABSTRACT

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Subject(s)
Equipment Design , Lighting , Ureteroscopes , Ureteroscopy , Light , Humans , Saline Solution , Color
7.
World J Urol ; 42(1): 240, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38630158

ABSTRACT

PURPOSE: To evaluate the impact of ureteroscope position within renal cavities as well as different locations of the tip of the ureteral access sheath (UAS) on fluid dynamics during retrograde intrarenal surgery (RIRS). MATERIALS AND METHODS: A prospective observational clinical study was performed. Measurements with a flexible ureteroscope placed in the upper, middle and lower calyces were obtained with the tip of the UAS placed either 2 cm below the pyelo-ureteric junction (PUJ), or at the level of the iliac crest. RESULTS: 74 patients were included. The outflow rates from the middle and upper calyxes were statistically significantly higher compared to the lower calyx, both with the UAS close to the pyelo-ureteric junction and at the iliac crest. When the UAS was withdrawn and positioned at the level of the iliac crest, a significant decrease in outflow rates from the upper (40.1 ± 4.3 ml/min vs 35.8 ± 4.1 ml/min) and middle calyces (40.6 ± 4.0 ml/min vs 36.8 ± 4.6 ml/min) and an increase in the outflow from the lower calyx (28.5 ± 3.3 ml/min vs 33.7 ± 5.7 ml/min) were noted. CONCLUSIONS: Our study showed that higher fluid outflow rates are observed from upper and middle calyces compared to lower calyx. This was true when the UAS was positioned 2 cm below the PUJ and at the iliac crest. Significant worsening of fluid dynamics from upper and middle calyces was observed when the UAS was placed distally at the level of the iliac crest. While the difference was statistically significant, the absolute change was not significant. In contrast, for lower calyces, a statistically significant improvement was documented.


Subject(s)
Ureter , Ureteroscopes , Humans , Hydrodynamics , Kidney , Endoscopy , Ureter/surgery
8.
World J Urol ; 42(1): 266, 2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38676726

ABSTRACT

PURPOSE: Considering the existing gaps in the literature regarding patient radiation dose (RD) and its associated risks, a systematic review of the literature on RD was conducted, focusing on percutaneous nephrolithotomy (PCNL), extracorporeal shock wave lithotripsy (SWL), and ureteroscopy (URS). METHODS: Two authors conducted a literature search on PubMed, Web of Science, and Google Scholar to identify studies on RD during endourological procedures. Two thousand two hundred sixty-six articles were screened. Sixty-five publications met the inclusion criteria using the PRISMA standards. RESULTS: RD was generally highest for PCNL, reaching levels up to 33 mSv, 28,700 mGycm2, and 430.8 mGy. This was followed by SWL, with RD reaching up to 7.32 mSv, 13,082 mGycm2, and 142 mGy. URS demonstrated lower RD, reaching up to 6.07 mSv, 8920 mGycm2, and 46.99 mGy. Surgeon experience and case load were inversely associated with RD. Strategies such as optimizing fluoroscopy settings, implementing ultrasound (US), and following the ALARA (As Low As Reasonably Achievable) principle minimized RD. CONCLUSIONS: This is the first systematic review analyzing RD, which was generally highest during PCNL, followed by SWL and URS. There is no specific RD limit for these procedures. Implementation of strategies such as optimizing fluoroscopy settings, utilizing US, and adhering to the ALARA principle proved effective in reducing RD. However, further research is needed to explore the factors influencing RD, assess their impact on patient outcomes, and establish procedure-specific reference levels for RD.


Subject(s)
Lithotripsy , Nephrolithotomy, Percutaneous , Radiation Exposure , Ureteroscopy , Humans , Ureteroscopy/adverse effects , Nephrolithotomy, Percutaneous/adverse effects , Nephrolithotomy, Percutaneous/methods , Lithotripsy/adverse effects , Lithotripsy/methods , Radiation Dosage
9.
World J Urol ; 42(1): 188, 2024 Mar 23.
Article in English | MEDLINE | ID: mdl-38520528

ABSTRACT

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Subject(s)
Lighting , Ureteroscopes , Humans , Equipment Design , Urologists , Disposable Equipment , Ureteroscopy
10.
World J Urol ; 42(1): 163, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38488927

ABSTRACT

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Subject(s)
Occupational Exposure , Radiation Exposure , Radiation Protection , Humans , Prospective Studies , Occupational Exposure/prevention & control , Fluoroscopy/adverse effects , Radiation Exposure/prevention & control , Radiation Dosage
12.
World J Urol ; 42(1): 46, 2024 Jan 20.
Article in English | MEDLINE | ID: mdl-38244083

ABSTRACT

PURPOSE: Urolithiasis has become increasingly prevalent, leading to higher disability-adjusted life years and deaths. Various stone classification systems have been developed to enhance the understanding of lithogenesis, aid urologists in treatment decisions, and predict recurrence risk. The aim of this manuscript is to provide an overview of different stone classification criteria. METHODS: Two authors conducted a review of literature on studies relating to the classification of urolithiasis. A narrative synthesis for analysis of the studies was used. RESULTS: Stones can be categorized based on anatomical position, size, medical imaging features, risk of recurrence, etiology, composition, and morphoconstitutional analysis. The first three mentioned offer a straightforward approach to stone classification, directly influencing treatment recommendations. With the routine use of CT imaging before treatment, precise details like anatomical location, stone dimensions, and Hounsfield Units can be easily determined, aiding treatment planning. In contrast, classifying stones based on risk of recurrence and etiology is more complex due to dependencies on multiple variables, including stone composition and morphology. A classification system based on morphoconstitutional analysis, which combines morphological stone appearance and chemical composition, has demonstrated its value. It allows for the rapid identification of crystalline phase principles, the detection of crystalline conversion processes, the determination of etiopathogenesis, the recognition of lithogenic processes, the assessment of crystal formation speed, related recurrence rates, and guidance for selecting appropriate treatment modalities. CONCLUSIONS: Recognizing that no single classification system can comprehensively cover all aspects, the integration of all classification approaches is essential for tailoring urolithiasis patient-specific management.


Subject(s)
Lithotripsy , Urolithiasis , Humans , Urolithiasis/therapy , Diagnostic Imaging , Lithotripsy/methods , Urologists
13.
Cent European J Urol ; 76(3): 245-250, 2023.
Article in English | MEDLINE | ID: mdl-38045778

ABSTRACT

Introduction: The area of paediatric endourology is unique and is recognised to be challenging, and it requires a certain level of focused training and expertise. Our aim was to conduct a worldwide survey in order to gain an overview regarding the current practice patterns for minimally invasive treatments of paediatric upper urinary tract stone patients. Material and methods: The survey was distributed between December 2021 and April 2022 through urology sections and societies in United Kingdom, Latin America and Asia. The survey was made up of 20 questions and it was distributed online using the free online Google Forms (TM). Results: 221 urologists answered the survey with 56 responses each from India, South America and UK and 53 responses from the rest of Europe (15 countries). In total, 163 responders (73.7%) managed paediatric stone patients in their daily practice. Of the responders, 60.2% were adult urologists and 39.8% were paediatric urologists. 12.9% adult urologists and 20.4% paediatric urologists run independent clinics while some run combined adult and paediatric clinics sometimes with the support of the nephrologists. Only 33.9% urologists offered all surgical treatments [extracorporeal shock wave lithotripsy (ESWL), percutaneous nephrolithotomy (PCNL), ureteroscopy (URS) and retrograde intrarenal surgery (RIRS)]. Conclusions: Treatment of paediatric stones can vary according to country and legislations. Based on the results of this survey, minimally invasive methods such as URS and mini PCNL seem to have become more popular. In most institutions a collaboration exists between adult and paediatric urologists, which is the key for a tailored decision making, counselling and treatment success.

14.
Eur Urol Focus ; 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-37940392

ABSTRACT

CONTEXT: Laser performance for lithotripsy is currently reported using units of measurement such as J/mm3, mm3/J, mm3/s, s/mm3, and mm3/min. However, there are no current standardized definitions or terminology for these metrics. This may lead to confusion when assessing and comparing different laser systems. OBJECTIVE: The primary objective was to summarize outcome values and corresponding terminology from studies on laser lithotripsy performance using stone volume in relation to time or energy. The secondary objective was to propose a standardized terminology for reporting laser performance metrics. EVIDENCE ACQUISITION: A systematic review of the literature was conducted using the search string ("j*/mm3" OR "mm3/j*" OR "mm3/s*" OR "s*/mm3" OR "mm3/min*" OR "min*/mm3" AND "lithotripsy") on Scopus, Web of Science, Embase, and PubMed databases. Study selection, data extraction, and quality assessment were performed independently by two authors. EVIDENCE SYNTHESIS: A total of 28 studies were included, covering holmium:yttrium-aluminum-garnet (Ho:YAG), MOSES, and thulium fiber laser (TFL) technologies. Laser energy consumption values reported for the studies ranged from 2.0 - 43.5 J/mm3in vitro and from 2.7 - 47.8 J/mm3in vivo, translating to laser ablation efficiency of 0.023 - 0.500 mm3/J and 0.021 - 0.370 mm3/J, respectively. Laser ablation speeds ranged from 0.3 - 8.5 mm3/s in vivo, translating to lasing time consumption of 0.12 - 3.33 s/mm3. Laser efficacy ranged from 4.35 - 51.7 mm3/min in vivo. There was high heterogeneity for the terminology used to describe laser performance for the same metrics. CONCLUSIONS: The range of laser performance metric values relating stone volume to energy or time is wide, with corresponding differing terminology. We propose a standardized terminology for future studies on laser lithotripsy, including laser ablation efficiency (mm3/J), laser ablation speed (mm3/s), and laser energy consumption (J/mm3). Laser efficacy (mm3/min) is proposed as a broader term that is based on the total operative time, encompassing the whole technique using the laser. PATIENT SUMMARY: We reviewed studies to identify the units and terms used for laser performance when treating urinary stones. The review revealed a wide range of differing units, outcomes, and terms. Therefore, we propose a standardized terminology for future studies on laser stone treatment.

15.
Front Surg ; 10: 1274583, 2023.
Article in English | MEDLINE | ID: mdl-37780913

ABSTRACT

Ureteroscopy has become an increasingly popular surgical intervention for conditions such as urinary stone disease. As new technologies and techniques become available, debate regarding their proper use has risen. This includes the role of single use ureteroscopes, optimal laser for stone lithotripsy, basketing versus dusting, the impact of ureteral access sheath, the need for safety guidewire, fluoroscopy free URS, imaging and follow up practices are all areas which have generated a lot of debate. This review serves to evaluate each of these issues and provide a balanced conclusion to guide the clinician in their practice.

16.
World J Urol ; 41(12): 3723-3730, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37831156

ABSTRACT

BACKGROUND: The novel pulsed thulium:yttrium-aluminum-garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. METHODS: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm3, UA: 1.55 mg/mm3). RESULTS: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm3/J (COM) and 0.026, 0.030, 0.039 mm3/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm3 (COM) and 50, 36, 26 J/mm3 (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). CONCLUSION: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.


Subject(s)
Lasers, Solid-State , Lithotripsy, Laser , Lithotripsy , Nephrolithiasis , Urinary Calculi , Humans , Lasers, Solid-State/therapeutic use , Thulium , Lithotripsy, Laser/methods , Urinary Calculi/therapy , Calcium Oxalate , Holmium
17.
World J Urol ; 41(12): 3705-3711, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37855897

ABSTRACT

INTRODUCTION: The aims of the study: (1) to compare the Super Pulse Thulium Fiber Laser (SP TFL) and the holmium: yttrium-aluminium-garnet (Ho:YAG) lasers in retrograde intrarenal surgery (RIRS); (2) to compare the efficacy of SP TFL laser fibers of different diameters (150 µm and 200 µm). METHODS: A prospective randomized single-blinded trial was conducted. Patients with stones from 10 to 20 mm were randomly assigned RIRS in three groups: (1) SP TFL (NTO IRE-Polus, Russia) with fiber diameter of 150 µm; (2) SP TFL with 200-µm fiber; and (3) Ho:YAG (Lumenis, USA) with 200-µm fiber. RESULTS: Ninety-six patients with kidney stones were randomized to undergo RIRS with SP TFL using a 150-µm fiber (34 patients) and a 200-µm fiber (32 patients) and RIRS with Ho:YAG (30 patients). The median laser on time (LOT) in the 200-µm SP TFL group was 9.2 (6.2-14.6) min, in 150-µm SP TFL-11.4 (7.7-14.9) min (p = 0.390), in Ho:YAG-14.1 (10.8-18.1) min (p = 0.021). The total energy consumed in 200-µm SP TFL was 8.4 (5.8-15.2) kJ; 150-µm SP TFL - 10.8 (7.3-13.5) kJ (p = 0.626) and in Ho:YAG-15.2 (11.1-25.3) kJ (p = 0.005). CONCLUSIONS: Irrespective of the density, RIRS with SP TFL laser has proven to be both a safe and effective procedure. Whilst the introduction of smaller fibers may have the potential to reduce the duration of surgery, SP TFL results in a reduction in the LOT and total energy for stone ablation in RIRS compared with Ho:YAG.


Subject(s)
Kidney Calculi , Lasers, Solid-State , Lithotripsy, Laser , Humans , Lithotripsy, Laser/methods , Thulium , Prospective Studies , Kidney Calculi/surgery , Lasers, Solid-State/therapeutic use , Holmium
18.
World J Urol ; 41(11): 3301-3308, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37682286

ABSTRACT

INTRODUCTION: Several preclinical studies about a novel pulsed-thulium:yttrium-aluminum-garnet (p-Tm:YAG) device have been published, demonstrating its possible clinical relevance. METHODS: We systematically reviewed the reality and expectations for this new p-Tm:YAG technology. A PubMed, Scopus and Embase search were performed. All relevant studies and data identified in the bibliographic search were selected, categorized, and summarized. RESULTS: Tm:YAG is a solid state diode-pumped laser that emits at a wavelength of 2013 nm, in the infrared spectrum. Despite being close to the Ho:YAG emission wavelength (2120 nm), Tm:YAG is much closer to the water absorption peak and has higher absorption coefficient in liquid water. At present, there very few evaluations of the commercially available p-Tm:YAG devices. There is a lack of information on how the technical aspects, functionality and pulse mechanism can be maximized for clinical utility. Available preclinical studies suggest that p-Tm:YAG laser may potentially increase the ablated stone weight as compared to Ho:YAG under specific condition and similar laser parameters, showing lower retropulsion as well. Regarding laser safety, a preclinical study observed similar absolute temperature and cumulative equivalent minutes at 43° C as compared to Ho:YAG. Finally, laser-associated soft-tissue damage was assessed at histological level, showing similar extent of alterations due to coagulation and necrosis when compared with the other clinically relevant lasers. CONCLUSIONS: The p-Tm:YAG appears to be a potential alternative to the Ho:YAG and TFL according to these preliminary laboratory data. Due to its novelty, further studies are needed to broaden our understanding of its functioning and clinical applicability.


Subject(s)
Lasers, Solid-State , Lithotripsy, Laser , Humans , Lasers, Solid-State/therapeutic use , Thulium , Temperature , Water , Holmium
19.
J Clin Med ; 12(17)2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37685776

ABSTRACT

Flexible ureteroscopy (fURS) with laser lithotripsy is currently the gold standard surgical treatment for ureteral and kidney stones with a maximum diameter of 2 cm [...].