Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Radiol ; 86(1021): 31197714, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22723511

ABSTRACT

OBJECTIVES: To propose a method to study the effect of exposure settings on image quality and to estimate the potential for dose reduction when introducing dose-reducing measures. METHODS: Using the framework of visual grading regression (VGR), a log(mAs) term is included in the ordinal logistic regression equation, so that the effect of reducing the dose can be quantitatively related to the effect of adding post-processing. In the ordinal logistic regression, patient and observer identity are treated as random effects using generalised linear latent and mixed models. The potential dose reduction is then estimated from the regression coefficients. The method was applied in a single-image study of coronary CT angiography (CTA) to evaluate two-dimensional (2D) adaptive filters, and in an image-pair study of abdominal CT to evaluate 2D and three-dimensional (3D) adaptive filters. RESULTS: For five image quality criteria in coronary CTA, dose reductions of 16-26% were predicted when adding 2D filtering. Using five image quality criteria for abdominal CT, it was estimated that 2D filtering permits doses were reduced by 32-41%, and 3D filtering by 42-51%. CONCLUSIONS: VGR including a log(mAs) term can be used for predictions of potential dose reduction that may be useful for guiding researchers in designing subsequent studies evaluating diagnostic value. With appropriate statistical analysis, it is possible to obtain direct numerical estimates of the dose-reducing potential of novel acquisition, reconstruction or post-processing techniques.


Subject(s)
Radiation Dosage , Radiation Injuries/prevention & control , Radiation Protection/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiometry/methods , Tomography, X-Ray Computed/methods , Humans , Observer Variation , Radiation Injuries/etiology , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed/adverse effects
2.
Br J Radiol ; 86(1021): 20110784, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23239690

ABSTRACT

Objectives To propose a method to study the effect of exposure settings on image quality and to estimate the potential for dose reduction when introducing dose-reducing measures. Methods Using the framework of visual grading regression (VGR), a log(mAs) term is included in the ordinal logistic regression equation, so that the effect of reducing the dose can be quantitatively related to the effect of adding post-processing. In the ordinal logistic regression, patient and observer identity are treated as random effects using generalised linear latent and mixed models. The potential dose reduction is then estimated from the regression coefficients. The method was applied in a single-image study of coronary CT angiography (CTA) to evaluate two-dimensional (2D) adaptive filters, and in an image-pair study of abdominal CT to evaluate 2D and three-dimensional (3D) adaptive filters. Results For five image quality criteria in coronary CTA, dose reductions of 16-26% were predicted when adding 2D filtering. Using five image quality criteria for abdominal CT, it was estimated that 2D filtering permits doses were reduced by 32-41%, and 3D filtering by 42-51%. Conclusions VGR including a log(mAs) term can be used for predictions of potential dose reduction that may be useful for guiding researchers in designing subsequent studies evaluating diagnostic value. With appropriate statistical analysis, it is possible to obtain direct numerical estimates of the dose-reducing potential of novel acquisition, reconstruction or post-processing techniques.


Subject(s)
Algorithms , Radiation Dosage , Radiation Injuries/prevention & control , Radiation Protection/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiometry/methods , Tomography, X-Ray Computed/methods , Humans , Radiation Injuries/etiology , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed/adverse effects
3.
Mol Genet Metab ; 95(3): 127-32, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18722797

ABSTRACT

BACKGROUND: The diagnosis of pediatric neurologic disorders with a deficiency in the biosynthesis of either the neurotransmitters serotonin and dopamine, or the co-factor tetrahydrobiopterin or a cerebral 5-methyltetrahydrofolate (5-MTHF) deficiency, strongly relies on a robust analysis of neurotransmitter metabolites, pterins and 5-MTHF in the cerebrospinal fluid (CSF). The aim of this study was to investigate which technical and biochemical factors affect the CSF concentration of 5-MTHF, neopterin and biopterin in a pediatric population. METHODS: We studied effects of the ventriculo-spinal gradient, total protein concentration, pretreatment with ascorbic acid (in case of 5-MTHF analysis), pretreatment of CSF with trichloro acetic acid (TCA)/dithiotreitol (DTE) and oxidation with either iodine or manganese oxide (in case of pterin analysis), storage time and age of the patients. We included CSF samples from children until the age of 18 years and analysed 5-MTHF, neopterin, biopterin, homovanillic acid (HVA), 5-hydroxy-indoleacetic acid (5-HIAA) and total protein. RESULTS: The major findings of our study are: (1) CSF 5-MTHF, neopterin and biopterin concentrations are not affected by the ventriculo-spinal gradient; (2) pretreatment of CSF with ascorbic acid has negligible effects on 5-MTHF concentrations; (3) pretreatment of CSF with TCA/DTE and oxidation with iodine results in the most accurate determination of neopterin and biopterin; (4) when adjusted for age and total protein, CSF 5-MTHF correlated with 5-HIAA, but not with HVA; (5) the reference value of 5-MTHF in CSF in childhood is age-dependent (r=-0.634; p0.001); (6) we did not observe an age-dependency for neopterin and biopterin in CSF. CONCLUSION: 5-MTHF, neopterin and biopterin can be analysed in any volume of CSF that is collected. For correct analysis of pterins, CSF will have to be pretreated to stabilize the concentrations and stored properly, whereas such pretreatment is not necessary for 5-MTHF.


Subject(s)
Biopterins/cerebrospinal fluid , Neopterin/cerebrospinal fluid , Nervous System Diseases/diagnosis , Tetrahydrofolates/cerebrospinal fluid , Adolescent , Biopterins/chemistry , Child , Child, Preschool , Female , Humans , Infant , Male , Neopterin/chemistry , Nervous System Diseases/cerebrospinal fluid , Specimen Handling , Tetrahydrofolates/chemistry
4.
Br J Math Stat Psychol ; 19(2): 163-79, 1966 Nov.
Article in English | MEDLINE | ID: mdl-5979110

Subject(s)
Mathematics , Music , Humans
5.
Annu Rev Psychol ; 17: 145-76, 1966.
Article in English | MEDLINE | ID: mdl-5322633

Subject(s)
Cognition , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...