Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
NMR Biomed ; : e5214, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38982853

ABSTRACT

Quantitative muscle magnetic resonance imaging (qMRI) is a valuable methodology for assessing muscular injuries and neuromuscular disorders. Notably, muscle diffusion tensor imaging (DTI) gives insights into muscle microstructural and macrostructural characteristics. However, the long-term reproducibility and robustness of these measurements remain relatively unexplored. The purpose of this prospective longitudinal cohort study was to assess the long-term robustness and range of variation of qMRI parameters, especially DTI metrics, in the lower extremity muscles of healthy controls under real-life conditions. Twelve volunteers (seven females, age 44.1 ± 12.1 years, body mass index 23.3 ± 2.0 kg/m2) underwent five leg muscle MRI sessions every 20 ± 4 weeks over a total period of 1.5 years. A multiecho gradient-echo Dixon-based sequence, a multiecho spin-echo T2-mapping sequence, and a spin-echo echo planar imaging diffusion-weighted sequence were acquired bilaterally with a Philips 3-T Achieva MR System using a 16-channel torso coil. Fifteen leg muscles were segmented in both lower extremities. qMRI parameters, including fat fraction (FF), water T2 relaxation time, and the diffusion metrics fractional anisotropy (FA) and mean diffusivity (MD), were evaluated. Coefficients of variance (wsCV) and intraclass correlation coefficients (ICCs) were calculated to assess the reproducibility of qMRI parameters. The standard error of measurement (SEM) and the minimal detectable change (MDC) were calculated to determine the range of variation. All tests were applied to all muscles and, subsequently, to each muscle separately. wsCV showed good reproducibility (≤ 10%) for all qMRI parameters in all muscles. The ICCs revealed excellent agreement between time points (FF = 0.980, water T2 = 0.941, FA = 0.952, MD = 0.948). Random measurement errors assessed by SEM and the MDC were low (< 12%). In conclusion, in this study, we showed that qMRI parameters in healthy volunteers living normal lives are stable over 18 months, thereby defining a benchmark for the expected range of variation over time.

2.
NMR Biomed ; : e5172, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38794994

ABSTRACT

Limb-girdle muscular dystrophy (LGMD) type R1 (LGMDR1) is the most common subtype of LGMD in Europe. Prospective longitudinal data, including clinical assessments and new biomarkers such as quantitative magnetic resonance imaging (qMRI), are needed to evaluate the natural course of the disease and therapeutic options. We evaluated eight thigh and seven leg muscles of 13 LGMDR1 patients (seven females, mean age 36.7 years, body mass index 23.9 kg/m2) and 13 healthy age- and gender-matched controls in a prospective longitudinal design over 1 year. Clinical assessment included testing for muscle strength with quick motor function measure (QMFM), gait analysis and patient questionnaires (neuromuscular symptom score, activity limitation [ACTIVLIM]). MRI scans were performed on a 3-T MRI scanner, including a Dixon-based sequence, T2 mapping and diffusion tensor imaging. The qMRI values of fat fraction (FF), water T2 relaxation time (T2), fractional anisotropy, mean diffusivity, axial diffusivity and radial diffusivity were analysed. Within the clinical outcome measures, significant deterioration between baseline and follow-up was found for ACTIVLIM (p = 0.029), QMFM (p = 0.012). Analysis of qMRI parameters of the patient group revealed differences between time points for both FF and T2 when analysing all muscles (FF: p < 0.001; T2: p = 0.016). The highest increase of fat replacement was found in muscles with an FF of between 10% and 50% at baseline. T2 in muscles with low-fat replacement increased significantly. No significant differences were found for the diffusion metrics. Significant correlations between qMRI metrics and clinical assessments were found at baseline and follow-up, while only T2 changes in thigh muscles correlated with changes in ACTIVLIM over time (ρ = -0.621, p < 0.05). Clinical assessments can show deterioration of the general condition of LGMDR1 patients. qMRI measures can give additional information about underlying pathophysiology. Further research is needed to establish qMRI outcome measures for clinical trials.

SELECTION OF CITATIONS
SEARCH DETAIL
...